A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra

AIM: The purpose of this study is to examine the intensity of light curing units and factors affecting it in dental offices. MATERIALS AND METHODS: The output intensity of 200 light curing units in dental offices across Maharashtra were examined. The collection of related information (thenumber of m...

Descripción completa

Detalles Bibliográficos
Autores principales: Hegde, Vivek, Jadhav, Sameer, Aher, Gayatri B
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2879716/
https://www.ncbi.nlm.nih.gov/pubmed/20543916
http://dx.doi.org/10.4103/0972-0707.57633
_version_ 1782181953101889536
author Hegde, Vivek
Jadhav, Sameer
Aher, Gayatri B
author_facet Hegde, Vivek
Jadhav, Sameer
Aher, Gayatri B
author_sort Hegde, Vivek
collection PubMed
description AIM: The purpose of this study is to examine the intensity of light curing units and factors affecting it in dental offices. MATERIALS AND METHODS: The output intensity of 200 light curing units in dental offices across Maharashtra were examined. The collection of related information (thenumber of months of use of curing unit, the approximate number of times used in a day, and presence or absence of composite build-ups) and measurement of the intensity was performed by two operators. L.E.D Radiometer (Kerr) was used for measuring the output intensity. The average output intensity was divided into three categories (<200 mW/cm(2), 200-400 mW/ cm(2)and >400 mW/cm(2)). RESULTS: Among the 200 curing units examined, 81 were LED units and 119 were QTH units. Only 10% LED machines and 2% QTH curing units had good intensities (>400 mW/cm( 2)). CONCLUSION: Most of the examined curing lights had low output intensity ranging from 200 to 400 mW/cm(2), and most of the curing units had composite build-ups on them.
format Text
id pubmed-2879716
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-28797162010-06-11 A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra Hegde, Vivek Jadhav, Sameer Aher, Gayatri B J Conserv Dent Original Article AIM: The purpose of this study is to examine the intensity of light curing units and factors affecting it in dental offices. MATERIALS AND METHODS: The output intensity of 200 light curing units in dental offices across Maharashtra were examined. The collection of related information (thenumber of months of use of curing unit, the approximate number of times used in a day, and presence or absence of composite build-ups) and measurement of the intensity was performed by two operators. L.E.D Radiometer (Kerr) was used for measuring the output intensity. The average output intensity was divided into three categories (<200 mW/cm(2), 200-400 mW/ cm(2)and >400 mW/cm(2)). RESULTS: Among the 200 curing units examined, 81 were LED units and 119 were QTH units. Only 10% LED machines and 2% QTH curing units had good intensities (>400 mW/cm( 2)). CONCLUSION: Most of the examined curing lights had low output intensity ranging from 200 to 400 mW/cm(2), and most of the curing units had composite build-ups on them. Medknow Publications 2009 /pmc/articles/PMC2879716/ /pubmed/20543916 http://dx.doi.org/10.4103/0972-0707.57633 Text en Copyright: © Journal of Conservative Dentistry http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hegde, Vivek
Jadhav, Sameer
Aher, Gayatri B
A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra
title A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra
title_full A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra
title_fullStr A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra
title_full_unstemmed A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra
title_short A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra
title_sort clinical survey of the output intensity of 200 light curing units in dental offices across maharashtra
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2879716/
https://www.ncbi.nlm.nih.gov/pubmed/20543916
http://dx.doi.org/10.4103/0972-0707.57633
work_keys_str_mv AT hegdevivek aclinicalsurveyoftheoutputintensityof200lightcuringunitsindentalofficesacrossmaharashtra
AT jadhavsameer aclinicalsurveyoftheoutputintensityof200lightcuringunitsindentalofficesacrossmaharashtra
AT ahergayatrib aclinicalsurveyoftheoutputintensityof200lightcuringunitsindentalofficesacrossmaharashtra
AT hegdevivek clinicalsurveyoftheoutputintensityof200lightcuringunitsindentalofficesacrossmaharashtra
AT jadhavsameer clinicalsurveyoftheoutputintensityof200lightcuringunitsindentalofficesacrossmaharashtra
AT ahergayatrib clinicalsurveyoftheoutputintensityof200lightcuringunitsindentalofficesacrossmaharashtra