Cargando…

Intraocular Lens Power Calculation After Corneal Refractive Surgery

Cataract surgery after corneal refractive surgery can be challenging for the ocular surgeon due to the difficulty with accurate intraocular lens (IOL) power determination and unexpected refractive surprises. As clinicians have done more work, a number of error sources have been determined. Furthermo...

Descripción completa

Detalles Bibliográficos
Autor principal: Feiz, Vahid
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2880376/
https://www.ncbi.nlm.nih.gov/pubmed/20543939
http://dx.doi.org/10.4103/0974-9233.61219
_version_ 1782182022246039552
author Feiz, Vahid
author_facet Feiz, Vahid
author_sort Feiz, Vahid
collection PubMed
description Cataract surgery after corneal refractive surgery can be challenging for the ocular surgeon due to the difficulty with accurate intraocular lens (IOL) power determination and unexpected refractive surprises. As clinicians have done more work, a number of error sources have been determined. Furthermore, an increasing number of methods to avoid these refractive surprises have been proposed. The combination of this work has resulted in recommendations for the modification of standard IOL power calculations to improve outcomes. The following article includes a brief on, and by no means, inclusive, error sources and ways to compensate for them.
format Text
id pubmed-2880376
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-28803762010-06-11 Intraocular Lens Power Calculation After Corneal Refractive Surgery Feiz, Vahid Middle East Afr J Ophthalmol Cornea/Refractive Update Cataract surgery after corneal refractive surgery can be challenging for the ocular surgeon due to the difficulty with accurate intraocular lens (IOL) power determination and unexpected refractive surprises. As clinicians have done more work, a number of error sources have been determined. Furthermore, an increasing number of methods to avoid these refractive surprises have been proposed. The combination of this work has resulted in recommendations for the modification of standard IOL power calculations to improve outcomes. The following article includes a brief on, and by no means, inclusive, error sources and ways to compensate for them. Medknow Publications 2010 /pmc/articles/PMC2880376/ /pubmed/20543939 http://dx.doi.org/10.4103/0974-9233.61219 Text en © Middle East African Journal of Ophthalmology http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cornea/Refractive Update
Feiz, Vahid
Intraocular Lens Power Calculation After Corneal Refractive Surgery
title Intraocular Lens Power Calculation After Corneal Refractive Surgery
title_full Intraocular Lens Power Calculation After Corneal Refractive Surgery
title_fullStr Intraocular Lens Power Calculation After Corneal Refractive Surgery
title_full_unstemmed Intraocular Lens Power Calculation After Corneal Refractive Surgery
title_short Intraocular Lens Power Calculation After Corneal Refractive Surgery
title_sort intraocular lens power calculation after corneal refractive surgery
topic Cornea/Refractive Update
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2880376/
https://www.ncbi.nlm.nih.gov/pubmed/20543939
http://dx.doi.org/10.4103/0974-9233.61219
work_keys_str_mv AT feizvahid intraocularlenspowercalculationaftercornealrefractivesurgery