Cargando…

Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View

Integrative approaches to studying the coupled dynamics of skeletal muscles with their loads while under neural control have focused largely on questions pertaining to the postural and dynamical stability of animals and humans. Prior studies have focused on how the central nervous system actively mo...

Descripción completa

Detalles Bibliográficos
Autores principales: Farahat, Waleed A., Herr, Hugh M.
Formato: Texto
Lenguaje:English
Publicado: Public Library of Science 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2880559/
https://www.ncbi.nlm.nih.gov/pubmed/20532203
http://dx.doi.org/10.1371/journal.pcbi.1000795
_version_ 1782182033386110976
author Farahat, Waleed A.
Herr, Hugh M.
author_facet Farahat, Waleed A.
Herr, Hugh M.
author_sort Farahat, Waleed A.
collection PubMed
description Integrative approaches to studying the coupled dynamics of skeletal muscles with their loads while under neural control have focused largely on questions pertaining to the postural and dynamical stability of animals and humans. Prior studies have focused on how the central nervous system actively modulates muscle mechanical impedance to generate and stabilize motion and posture. However, the question of whether muscle impedance properties can be neurally modulated to create favorable mechanical energetics, particularly in the context of periodic tasks, remains open. Through muscle stiffness tuning, we hypothesize that a pair of antagonist muscles acting against a common load may produce significantly more power synergistically than individually when impedance matching conditions are met between muscle and load. Since neurally modulated muscle stiffness contributes to the coupled muscle-load stiffness, we further anticipate that power-optimal oscillation frequencies will occur at frequencies greater than the natural frequency of the load. These hypotheses were evaluated computationally by applying optimal control methods to a bilinear muscle model, and also evaluated through in vitro measurements on frog Plantaris longus muscles acting individually and in pairs upon a mass-spring-damper load. We find a 7-fold increase in mechanical power when antagonist muscles act synergistically compared to individually at a frequency higher than the load natural frequency. These observed behaviors are interpreted in the context of resonance tuning and the engineering notion of impedance matching. These findings suggest that the central nervous system can adopt strategies to harness inherent muscle impedance in relation to external loads to attain favorable mechanical energetics.
format Text
id pubmed-2880559
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-28805592010-06-07 Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View Farahat, Waleed A. Herr, Hugh M. PLoS Comput Biol Research Article Integrative approaches to studying the coupled dynamics of skeletal muscles with their loads while under neural control have focused largely on questions pertaining to the postural and dynamical stability of animals and humans. Prior studies have focused on how the central nervous system actively modulates muscle mechanical impedance to generate and stabilize motion and posture. However, the question of whether muscle impedance properties can be neurally modulated to create favorable mechanical energetics, particularly in the context of periodic tasks, remains open. Through muscle stiffness tuning, we hypothesize that a pair of antagonist muscles acting against a common load may produce significantly more power synergistically than individually when impedance matching conditions are met between muscle and load. Since neurally modulated muscle stiffness contributes to the coupled muscle-load stiffness, we further anticipate that power-optimal oscillation frequencies will occur at frequencies greater than the natural frequency of the load. These hypotheses were evaluated computationally by applying optimal control methods to a bilinear muscle model, and also evaluated through in vitro measurements on frog Plantaris longus muscles acting individually and in pairs upon a mass-spring-damper load. We find a 7-fold increase in mechanical power when antagonist muscles act synergistically compared to individually at a frequency higher than the load natural frequency. These observed behaviors are interpreted in the context of resonance tuning and the engineering notion of impedance matching. These findings suggest that the central nervous system can adopt strategies to harness inherent muscle impedance in relation to external loads to attain favorable mechanical energetics. Public Library of Science 2010-06-03 /pmc/articles/PMC2880559/ /pubmed/20532203 http://dx.doi.org/10.1371/journal.pcbi.1000795 Text en Farahat, Herr. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Farahat, Waleed A.
Herr, Hugh M.
Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View
title Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View
title_full Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View
title_fullStr Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View
title_full_unstemmed Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View
title_short Optimal Workloop Energetics of Muscle-Actuated Systems: An Impedance Matching View
title_sort optimal workloop energetics of muscle-actuated systems: an impedance matching view
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2880559/
https://www.ncbi.nlm.nih.gov/pubmed/20532203
http://dx.doi.org/10.1371/journal.pcbi.1000795
work_keys_str_mv AT farahatwaleeda optimalworkloopenergeticsofmuscleactuatedsystemsanimpedancematchingview
AT herrhughm optimalworkloopenergeticsofmuscleactuatedsystemsanimpedancematchingview