Cargando…
A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations
An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germ...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer US
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2882037/ https://www.ncbi.nlm.nih.gov/pubmed/20309731 http://dx.doi.org/10.1007/s10439-010-9966-9 |
_version_ | 1782182155874467840 |
---|---|
author | Tomaszewski, P. K. Verdonschot, N. Bulstra, S. K. Verkerke, G. J. |
author_facet | Tomaszewski, P. K. Verdonschot, N. Bulstra, S. K. Verkerke, G. J. |
author_sort | Tomaszewski, P. K. |
collection | PubMed |
description | An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants. |
format | Text |
id | pubmed-2882037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-28820372010-06-10 A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations Tomaszewski, P. K. Verdonschot, N. Bulstra, S. K. Verkerke, G. J. Ann Biomed Eng Article An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants. Springer US 2010-03-23 2010 /pmc/articles/PMC2882037/ /pubmed/20309731 http://dx.doi.org/10.1007/s10439-010-9966-9 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Article Tomaszewski, P. K. Verdonschot, N. Bulstra, S. K. Verkerke, G. J. A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations |
title | A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations |
title_full | A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations |
title_fullStr | A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations |
title_full_unstemmed | A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations |
title_short | A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations |
title_sort | comparative finite-element analysis of bone failure and load transfer of osseointegrated prostheses fixations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2882037/ https://www.ncbi.nlm.nih.gov/pubmed/20309731 http://dx.doi.org/10.1007/s10439-010-9966-9 |
work_keys_str_mv | AT tomaszewskipk acomparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT verdonschotn acomparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT bulstrask acomparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT verkerkegj acomparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT tomaszewskipk comparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT verdonschotn comparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT bulstrask comparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations AT verkerkegj comparativefiniteelementanalysisofbonefailureandloadtransferofosseointegratedprosthesesfixations |