Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer
PURPOSE: To evaluate corneal biomechanical properties in eyes that had previously undergone penetrating keratoplasty (PK) using the ocular response analyzer (ORA). METHODS: We recruited 26 patients who had received unilateral PK. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-cor...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Ophthalmological Society
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2882075/ https://www.ncbi.nlm.nih.gov/pubmed/20532138 http://dx.doi.org/10.3341/kjo.2010.24.3.139 |
_version_ | 1782182159648292864 |
---|---|
author | Shin, Joo Young Choi, Jin Seok Oh, Joo Youn Kim, Mee Kum Lee, Jin Hak Wee, Won Ryang |
author_facet | Shin, Joo Young Choi, Jin Seok Oh, Joo Youn Kim, Mee Kum Lee, Jin Hak Wee, Won Ryang |
author_sort | Shin, Joo Young |
collection | PubMed |
description | PURPOSE: To evaluate corneal biomechanical properties in eyes that had previously undergone penetrating keratoplasty (PK) using the ocular response analyzer (ORA). METHODS: We recruited 26 patients who had received unilateral PK. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and cornea-compensated intraocular pressure (IOPcc) were measured with the ORA and were compared to the measurements from the contralateral eyes that did not undergo PK. RESULTS: The CH was 8.95±2.59 mmHg in eyes that underwent PK and 9.78±1.45 mmHg in the contralateral eyes that did not undergo PK (p=0.077). The CRF was 10.26±2.64 mmHg in post-PK eyes and 9.75±1.45 mmHg in the contralateral eyes (p=0.509), and the CH-CRF was significantly smaller in post-PK eyes (-1.31±2.32 mmHg in post-PK eyes vs. 0.03±0.88 mmHg in fellow eyes, p=0.016). The IOPg and IOPcc were significantly higher in the PK group than they were in the control group. The IOPcc's were 20.81±7.81 mmHg and 16.27±2.49 mmHg in post-PK and control eyes, respectively (p=0.011); and the IOPg's were 19.22±7.34 mmHg and 15.07±3.03 mmHg in post-PK and control eyes, respectively (p=0.019). The IOPcc-g's were 1.59±2.81 mmHg and 1.21±1.30 mmHg in post-PK and control eyes, respectively (p=0.412), and the central corneal thickness (CCT)'s were 489.11±90.60 µm and 556.24±42.84 µm in post-PK and control eyes, respectively (p=0.068). CONCLUSIONS: Following PK, CH tended to decrease while CRF tended to increase, significantly decreasing CH-CRF. A significantly higher intraocular pressure and a thinner CCT following PK may have contributed to the observed changes in these corneal biomechanical parameters. |
format | Text |
id | pubmed-2882075 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | The Korean Ophthalmological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-28820752010-06-08 Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer Shin, Joo Young Choi, Jin Seok Oh, Joo Youn Kim, Mee Kum Lee, Jin Hak Wee, Won Ryang Korean J Ophthalmol Original Article PURPOSE: To evaluate corneal biomechanical properties in eyes that had previously undergone penetrating keratoplasty (PK) using the ocular response analyzer (ORA). METHODS: We recruited 26 patients who had received unilateral PK. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and cornea-compensated intraocular pressure (IOPcc) were measured with the ORA and were compared to the measurements from the contralateral eyes that did not undergo PK. RESULTS: The CH was 8.95±2.59 mmHg in eyes that underwent PK and 9.78±1.45 mmHg in the contralateral eyes that did not undergo PK (p=0.077). The CRF was 10.26±2.64 mmHg in post-PK eyes and 9.75±1.45 mmHg in the contralateral eyes (p=0.509), and the CH-CRF was significantly smaller in post-PK eyes (-1.31±2.32 mmHg in post-PK eyes vs. 0.03±0.88 mmHg in fellow eyes, p=0.016). The IOPg and IOPcc were significantly higher in the PK group than they were in the control group. The IOPcc's were 20.81±7.81 mmHg and 16.27±2.49 mmHg in post-PK and control eyes, respectively (p=0.011); and the IOPg's were 19.22±7.34 mmHg and 15.07±3.03 mmHg in post-PK and control eyes, respectively (p=0.019). The IOPcc-g's were 1.59±2.81 mmHg and 1.21±1.30 mmHg in post-PK and control eyes, respectively (p=0.412), and the central corneal thickness (CCT)'s were 489.11±90.60 µm and 556.24±42.84 µm in post-PK and control eyes, respectively (p=0.068). CONCLUSIONS: Following PK, CH tended to decrease while CRF tended to increase, significantly decreasing CH-CRF. A significantly higher intraocular pressure and a thinner CCT following PK may have contributed to the observed changes in these corneal biomechanical parameters. The Korean Ophthalmological Society 2010-06 2010-06-05 /pmc/articles/PMC2882075/ /pubmed/20532138 http://dx.doi.org/10.3341/kjo.2010.24.3.139 Text en © 2010 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shin, Joo Young Choi, Jin Seok Oh, Joo Youn Kim, Mee Kum Lee, Jin Hak Wee, Won Ryang Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer |
title | Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer |
title_full | Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer |
title_fullStr | Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer |
title_full_unstemmed | Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer |
title_short | Evaluation of Corneal Biomechanical Properties Following Penetrating Keratoplasty Using the Ocular Response Analyzer |
title_sort | evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2882075/ https://www.ncbi.nlm.nih.gov/pubmed/20532138 http://dx.doi.org/10.3341/kjo.2010.24.3.139 |
work_keys_str_mv | AT shinjooyoung evaluationofcornealbiomechanicalpropertiesfollowingpenetratingkeratoplastyusingtheocularresponseanalyzer AT choijinseok evaluationofcornealbiomechanicalpropertiesfollowingpenetratingkeratoplastyusingtheocularresponseanalyzer AT ohjooyoun evaluationofcornealbiomechanicalpropertiesfollowingpenetratingkeratoplastyusingtheocularresponseanalyzer AT kimmeekum evaluationofcornealbiomechanicalpropertiesfollowingpenetratingkeratoplastyusingtheocularresponseanalyzer AT leejinhak evaluationofcornealbiomechanicalpropertiesfollowingpenetratingkeratoplastyusingtheocularresponseanalyzer AT weewonryang evaluationofcornealbiomechanicalpropertiesfollowingpenetratingkeratoplastyusingtheocularresponseanalyzer |