XML-BSPM: an XML format for storing Body Surface Potential Map recordings

BACKGROUND: The Body Surface Potential Map (BSPM) is an electrocardiographic method, for recording and displaying the electrical activity of the heart, from a spatial perspective. The BSPM has been deemed more accurate for assessing certain cardiac pathologies when compared to the 12-lead ECG. Never...

Descripción completa

Detalles Bibliográficos
Autores principales: Bond, Raymond R, Finlay, Dewar D, Nugent, Chris D, Moore, George
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2883957/
https://www.ncbi.nlm.nih.gov/pubmed/20470392
http://dx.doi.org/10.1186/1472-6947-10-28
_version_ 1782182293579759616
author Bond, Raymond R
Finlay, Dewar D
Nugent, Chris D
Moore, George
author_facet Bond, Raymond R
Finlay, Dewar D
Nugent, Chris D
Moore, George
author_sort Bond, Raymond R
collection PubMed
description BACKGROUND: The Body Surface Potential Map (BSPM) is an electrocardiographic method, for recording and displaying the electrical activity of the heart, from a spatial perspective. The BSPM has been deemed more accurate for assessing certain cardiac pathologies when compared to the 12-lead ECG. Nevertheless, the 12-lead ECG remains the most popular ECG acquisition method for non-invasively assessing the electrical activity of the heart. Although data from the 12-lead ECG can be stored and shared using open formats such as SCP-ECG, no open formats currently exist for storing and sharing the BSPM. As a result, an innovative format for storing BSPM datasets has been developed within this study. METHODS: The XML vocabulary was chosen for implementation, as opposed to binary for the purpose of human readability. There are currently no standards to dictate the number of electrodes and electrode positions for recording a BSPM. In fact, there are at least 11 different BSPM electrode configurations in use today. Therefore, in order to support these BSPM variants, the XML-BSPM format was made versatile. Hence, the format supports the storage of custom torso diagrams using SVG graphics. This diagram can then be used in a 2D coordinate system for retaining electrode positions. RESULTS: This XML-BSPM format has been successfully used to store the Kornreich-117 BSPM dataset and the Lux-192 BSPM dataset. The resulting file sizes were in the region of 277 kilobytes for each BSPM recording and can be deemed suitable for example, for use with any telemonitoring application. Moreover, there is potential for file sizes to be further reduced using basic compression algorithms, i.e. the deflate algorithm. Finally, these BSPM files have been parsed and visualised within a convenient time period using a web based BSPM viewer. CONCLUSIONS: This format, if widely adopted could promote BSPM interoperability, knowledge sharing and data mining. This work could also be used to provide conceptual solutions and inspire existing formats such as DICOM, SCP-ECG and aECG to support the storage of BSPMs. In summary, this research provides initial ground work for creating a complete BSPM management system.
format Text
id pubmed-2883957
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-28839572010-06-12 XML-BSPM: an XML format for storing Body Surface Potential Map recordings Bond, Raymond R Finlay, Dewar D Nugent, Chris D Moore, George BMC Med Inform Decis Mak Research Article BACKGROUND: The Body Surface Potential Map (BSPM) is an electrocardiographic method, for recording and displaying the electrical activity of the heart, from a spatial perspective. The BSPM has been deemed more accurate for assessing certain cardiac pathologies when compared to the 12-lead ECG. Nevertheless, the 12-lead ECG remains the most popular ECG acquisition method for non-invasively assessing the electrical activity of the heart. Although data from the 12-lead ECG can be stored and shared using open formats such as SCP-ECG, no open formats currently exist for storing and sharing the BSPM. As a result, an innovative format for storing BSPM datasets has been developed within this study. METHODS: The XML vocabulary was chosen for implementation, as opposed to binary for the purpose of human readability. There are currently no standards to dictate the number of electrodes and electrode positions for recording a BSPM. In fact, there are at least 11 different BSPM electrode configurations in use today. Therefore, in order to support these BSPM variants, the XML-BSPM format was made versatile. Hence, the format supports the storage of custom torso diagrams using SVG graphics. This diagram can then be used in a 2D coordinate system for retaining electrode positions. RESULTS: This XML-BSPM format has been successfully used to store the Kornreich-117 BSPM dataset and the Lux-192 BSPM dataset. The resulting file sizes were in the region of 277 kilobytes for each BSPM recording and can be deemed suitable for example, for use with any telemonitoring application. Moreover, there is potential for file sizes to be further reduced using basic compression algorithms, i.e. the deflate algorithm. Finally, these BSPM files have been parsed and visualised within a convenient time period using a web based BSPM viewer. CONCLUSIONS: This format, if widely adopted could promote BSPM interoperability, knowledge sharing and data mining. This work could also be used to provide conceptual solutions and inspire existing formats such as DICOM, SCP-ECG and aECG to support the storage of BSPMs. In summary, this research provides initial ground work for creating a complete BSPM management system. BioMed Central 2010-05-14 /pmc/articles/PMC2883957/ /pubmed/20470392 http://dx.doi.org/10.1186/1472-6947-10-28 Text en Copyright ©2010 Bond et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bond, Raymond R
Finlay, Dewar D
Nugent, Chris D
Moore, George
XML-BSPM: an XML format for storing Body Surface Potential Map recordings
title XML-BSPM: an XML format for storing Body Surface Potential Map recordings
title_full XML-BSPM: an XML format for storing Body Surface Potential Map recordings
title_fullStr XML-BSPM: an XML format for storing Body Surface Potential Map recordings
title_full_unstemmed XML-BSPM: an XML format for storing Body Surface Potential Map recordings
title_short XML-BSPM: an XML format for storing Body Surface Potential Map recordings
title_sort xml-bspm: an xml format for storing body surface potential map recordings
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2883957/
https://www.ncbi.nlm.nih.gov/pubmed/20470392
http://dx.doi.org/10.1186/1472-6947-10-28
work_keys_str_mv AT bondraymondr xmlbspmanxmlformatforstoringbodysurfacepotentialmaprecordings
AT finlaydeward xmlbspmanxmlformatforstoringbodysurfacepotentialmaprecordings
AT nugentchrisd xmlbspmanxmlformatforstoringbodysurfacepotentialmaprecordings
AT mooregeorge xmlbspmanxmlformatforstoringbodysurfacepotentialmaprecordings