Cargando…

Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification

BACKGROUND: The Bonfils intubating fiberscope has a limited upward tip angle of 40° and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather...

Descripción completa

Detalles Bibliográficos
Autores principales: Boedeker, Ben H, Barak-Bernhagen, Mary A, Miller, David J, Nicholas, Thomas A, Linnaus, Andrew, Murray, WB
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2890686/
https://www.ncbi.nlm.nih.gov/pubmed/20507596
http://dx.doi.org/10.1186/1471-227X-10-11
_version_ 1782182835463913472
author Boedeker, Ben H
Barak-Bernhagen, Mary A
Miller, David J
Nicholas, Thomas A
Linnaus, Andrew
Murray, WB
author_facet Boedeker, Ben H
Barak-Bernhagen, Mary A
Miller, David J
Nicholas, Thomas A
Linnaus, Andrew
Murray, WB
author_sort Boedeker, Ben H
collection PubMed
description BACKGROUND: The Bonfils intubating fiberscope has a limited upward tip angle of 40° and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The Center for Advanced Technology and Telemedicine at the University of Nebraska Medical Center has developed a novel fiberscope with a more anterior 60° curve to allow for easier midline insertion and intubation. The objective of this work was to evaluate the novel fiberscope, in comparison to the Bonfils intubating fiberscope, in terms of use and function in difficult airway intubation. METHODS: Twenty-two anesthesia providers participated in simulated intubations of a difficult airway mannequin to compare the Bonfils intubating fiberscope with the novel curved Boedeker intubating fiberscope. The intubations were assessed based upon the following variables: recorded Cormack Lehane airway scores, requests for cricoid pressure, time to intubation, number of intubation attempts and success or failure of the procedure. RESULTS: Participants using the Bonfils fiberscope recorded an average Cormack Lehane (CL) airway score of 1.67 ± 1.02 (median = 1); with the novel fiberscope, the recorded average airway grade improved to 1.18 ± 0.50 (median = 1). The difference in airway scores was not statistically significant (p = 0.34; Fishers Exact Test comparing CL grades 1&2 vs. 3&4). There was, however, a statistically significant difference in intubation success rates between the two devices. With the Bonfils fiberscope, 68% (15/22) of participants were successful in intubation compared to a 100% success rate in intubation with the novel fiberscope (22/22) (p = 0.008). After the intubation trial, the majority of participants (95%) indicated a preference for the novel fiberscope (n = 20). CONCLUSIONS: With this data, we can infer that the novel fiberscope curvature appears to improve or maintain the quality of an intubation attempt (airway score, cricoid pressure requirement, intubation time, number of attempts, placement success). The data indicate that the novel fiberscope offers a superior intubation experience to currently available best practices. The instrument was well received and would be welcomed by most study participants should the device become clinically available in the future.
format Text
id pubmed-2890686
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-28906862010-06-24 Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification Boedeker, Ben H Barak-Bernhagen, Mary A Miller, David J Nicholas, Thomas A Linnaus, Andrew Murray, WB BMC Emerg Med Research article BACKGROUND: The Bonfils intubating fiberscope has a limited upward tip angle of 40° and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The Center for Advanced Technology and Telemedicine at the University of Nebraska Medical Center has developed a novel fiberscope with a more anterior 60° curve to allow for easier midline insertion and intubation. The objective of this work was to evaluate the novel fiberscope, in comparison to the Bonfils intubating fiberscope, in terms of use and function in difficult airway intubation. METHODS: Twenty-two anesthesia providers participated in simulated intubations of a difficult airway mannequin to compare the Bonfils intubating fiberscope with the novel curved Boedeker intubating fiberscope. The intubations were assessed based upon the following variables: recorded Cormack Lehane airway scores, requests for cricoid pressure, time to intubation, number of intubation attempts and success or failure of the procedure. RESULTS: Participants using the Bonfils fiberscope recorded an average Cormack Lehane (CL) airway score of 1.67 ± 1.02 (median = 1); with the novel fiberscope, the recorded average airway grade improved to 1.18 ± 0.50 (median = 1). The difference in airway scores was not statistically significant (p = 0.34; Fishers Exact Test comparing CL grades 1&2 vs. 3&4). There was, however, a statistically significant difference in intubation success rates between the two devices. With the Bonfils fiberscope, 68% (15/22) of participants were successful in intubation compared to a 100% success rate in intubation with the novel fiberscope (22/22) (p = 0.008). After the intubation trial, the majority of participants (95%) indicated a preference for the novel fiberscope (n = 20). CONCLUSIONS: With this data, we can infer that the novel fiberscope curvature appears to improve or maintain the quality of an intubation attempt (airway score, cricoid pressure requirement, intubation time, number of attempts, placement success). The data indicate that the novel fiberscope offers a superior intubation experience to currently available best practices. The instrument was well received and would be welcomed by most study participants should the device become clinically available in the future. BioMed Central 2010-05-27 /pmc/articles/PMC2890686/ /pubmed/20507596 http://dx.doi.org/10.1186/1471-227X-10-11 Text en Copyright ©2010 Boedeker et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research article
Boedeker, Ben H
Barak-Bernhagen, Mary A
Miller, David J
Nicholas, Thomas A
Linnaus, Andrew
Murray, WB
Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
title Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
title_full Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
title_fullStr Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
title_full_unstemmed Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
title_short Improving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
title_sort improving rigid fiberoptic intubation: a comparison of the bonfils intubating fiberscope™ with a novel modification
topic Research article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2890686/
https://www.ncbi.nlm.nih.gov/pubmed/20507596
http://dx.doi.org/10.1186/1471-227X-10-11
work_keys_str_mv AT boedekerbenh improvingrigidfiberopticintubationacomparisonofthebonfilsintubatingfiberscopewithanovelmodification
AT barakbernhagenmarya improvingrigidfiberopticintubationacomparisonofthebonfilsintubatingfiberscopewithanovelmodification
AT millerdavidj improvingrigidfiberopticintubationacomparisonofthebonfilsintubatingfiberscopewithanovelmodification
AT nicholasthomasa improvingrigidfiberopticintubationacomparisonofthebonfilsintubatingfiberscopewithanovelmodification
AT linnausandrew improvingrigidfiberopticintubationacomparisonofthebonfilsintubatingfiberscopewithanovelmodification
AT murraywb improvingrigidfiberopticintubationacomparisonofthebonfilsintubatingfiberscopewithanovelmodification