Cargando…

Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations

The need to monitor, measure, and control sub-visible proteinaceous particulates in biopharmaceutical formulations has been emphasized in recent publications and commentaries. Some of these particulates can be highly transparent, fragile, and unstable. In addition, for much of the size range of conc...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Deepak K., King, Dave, Oma, Peter, Merchant, Clark
Formato: Texto
Lenguaje:English
Publicado: Springer US 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2895433/
https://www.ncbi.nlm.nih.gov/pubmed/20517661
http://dx.doi.org/10.1208/s12248-010-9205-1
_version_ 1782183256448303104
author Sharma, Deepak K.
King, Dave
Oma, Peter
Merchant, Clark
author_facet Sharma, Deepak K.
King, Dave
Oma, Peter
Merchant, Clark
author_sort Sharma, Deepak K.
collection PubMed
description The need to monitor, measure, and control sub-visible proteinaceous particulates in biopharmaceutical formulations has been emphasized in recent publications and commentaries. Some of these particulates can be highly transparent, fragile, and unstable. In addition, for much of the size range of concern, no practical measurement method with adequate sensitivity and repeatability has been available. A complication in measuring protein particulates in many formulations is the simultaneous presence of other particle types such as silicone micro-droplets, air bubbles, and extrinsic contaminants. The need has therefore been identified for new analytical methods which can accurately measure and characterize sub-visible particulates in formulations. Micro-flow imaging has been shown to provide high sensitivity in detecting and imaging transparent protein particles and a unique capability to independently analyze such populations even when other particle types are present.
format Text
id pubmed-2895433
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-28954332010-09-29 Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations Sharma, Deepak K. King, Dave Oma, Peter Merchant, Clark AAPS J Brief/Technical Note The need to monitor, measure, and control sub-visible proteinaceous particulates in biopharmaceutical formulations has been emphasized in recent publications and commentaries. Some of these particulates can be highly transparent, fragile, and unstable. In addition, for much of the size range of concern, no practical measurement method with adequate sensitivity and repeatability has been available. A complication in measuring protein particulates in many formulations is the simultaneous presence of other particle types such as silicone micro-droplets, air bubbles, and extrinsic contaminants. The need has therefore been identified for new analytical methods which can accurately measure and characterize sub-visible particulates in formulations. Micro-flow imaging has been shown to provide high sensitivity in detecting and imaging transparent protein particles and a unique capability to independently analyze such populations even when other particle types are present. Springer US 2010-06-02 /pmc/articles/PMC2895433/ /pubmed/20517661 http://dx.doi.org/10.1208/s12248-010-9205-1 Text en © American Association of Pharmaceutical Scientists 2010
spellingShingle Brief/Technical Note
Sharma, Deepak K.
King, Dave
Oma, Peter
Merchant, Clark
Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
title Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
title_full Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
title_fullStr Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
title_full_unstemmed Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
title_short Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
title_sort micro-flow imaging: flow microscopy applied to sub-visible particulate analysis in protein formulations
topic Brief/Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2895433/
https://www.ncbi.nlm.nih.gov/pubmed/20517661
http://dx.doi.org/10.1208/s12248-010-9205-1
work_keys_str_mv AT sharmadeepakk microflowimagingflowmicroscopyappliedtosubvisibleparticulateanalysisinproteinformulations
AT kingdave microflowimagingflowmicroscopyappliedtosubvisibleparticulateanalysisinproteinformulations
AT omapeter microflowimagingflowmicroscopyappliedtosubvisibleparticulateanalysisinproteinformulations
AT merchantclark microflowimagingflowmicroscopyappliedtosubvisibleparticulateanalysisinproteinformulations