Cargando…
Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain
One of the critical requirements of the emerging class of neural prosthetic devices is to maintain good quality neural recordings over long time periods. We report here a novel MEMS (Micro Electro Mechanical Systems) based technology that can move microelectrodes in the event of deterioration in neu...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Frontiers Research Foundation
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2896301/ https://www.ncbi.nlm.nih.gov/pubmed/20617188 http://dx.doi.org/10.3389/fneng.2010.00010 |
_version_ | 1782183335667171328 |
---|---|
author | Jackson, Nathan Sridharan, Arati Anand, Sindhu Baker, Michael Okandan, Murat Muthuswamy, Jit |
author_facet | Jackson, Nathan Sridharan, Arati Anand, Sindhu Baker, Michael Okandan, Murat Muthuswamy, Jit |
author_sort | Jackson, Nathan |
collection | PubMed |
description | One of the critical requirements of the emerging class of neural prosthetic devices is to maintain good quality neural recordings over long time periods. We report here a novel MEMS (Micro Electro Mechanical Systems) based technology that can move microelectrodes in the event of deterioration in neural signal to sample a new set of neurons. Microscale electro-thermal actuators are used to controllably move microelectrodes post-implantation in steps of approximately 9 μm. In this study, a total of 12 movable microelectrode chips were individually implanted in adult rats. Two of the twelve movable microelectrode chips were not moved over a period of 3 weeks and were treated as control experiments. During the first 3 weeks of implantation, moving the microelectrodes led to an improvement in the average signal to noise ratio (SNR) from 14.61 ± 5.21 dB before movement to 18.13 ± 4.99 dB after movement across all microelectrodes and all days. However, the average root-mean-square values of noise amplitudes were similar at 2.98 ± 1.22 μV and 3.01 ± 1.16 μV before and after microelectrode movement. Beyond 3 weeks, the primary observed failure mode was biological rejection of the PMMA (dental cement) based skull mount resulting in the device loosening and eventually falling from the skull. Additionally, the average SNR for functioning devices beyond 3 weeks was 11.88 ± 2.02 dB before microelectrode movement and was significantly different (p < 0.01) from the average SNR of 13.34 ± 0.919 dB after movement. The results of this study demonstrate that MEMS based technologies can move microelectrodes in rodent brains in long-term experiments resulting in improvements in signal quality. Further improvements in packaging and surgical techniques will potentially enable movable microelectrodes to record cortical neuronal activity in chronic experiments. |
format | Text |
id | pubmed-2896301 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Frontiers Research Foundation |
record_format | MEDLINE/PubMed |
spelling | pubmed-28963012010-07-08 Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain Jackson, Nathan Sridharan, Arati Anand, Sindhu Baker, Michael Okandan, Murat Muthuswamy, Jit Front Neuroengineering Neuroscience One of the critical requirements of the emerging class of neural prosthetic devices is to maintain good quality neural recordings over long time periods. We report here a novel MEMS (Micro Electro Mechanical Systems) based technology that can move microelectrodes in the event of deterioration in neural signal to sample a new set of neurons. Microscale electro-thermal actuators are used to controllably move microelectrodes post-implantation in steps of approximately 9 μm. In this study, a total of 12 movable microelectrode chips were individually implanted in adult rats. Two of the twelve movable microelectrode chips were not moved over a period of 3 weeks and were treated as control experiments. During the first 3 weeks of implantation, moving the microelectrodes led to an improvement in the average signal to noise ratio (SNR) from 14.61 ± 5.21 dB before movement to 18.13 ± 4.99 dB after movement across all microelectrodes and all days. However, the average root-mean-square values of noise amplitudes were similar at 2.98 ± 1.22 μV and 3.01 ± 1.16 μV before and after microelectrode movement. Beyond 3 weeks, the primary observed failure mode was biological rejection of the PMMA (dental cement) based skull mount resulting in the device loosening and eventually falling from the skull. Additionally, the average SNR for functioning devices beyond 3 weeks was 11.88 ± 2.02 dB before microelectrode movement and was significantly different (p < 0.01) from the average SNR of 13.34 ± 0.919 dB after movement. The results of this study demonstrate that MEMS based technologies can move microelectrodes in rodent brains in long-term experiments resulting in improvements in signal quality. Further improvements in packaging and surgical techniques will potentially enable movable microelectrodes to record cortical neuronal activity in chronic experiments. Frontiers Research Foundation 2010-06-18 /pmc/articles/PMC2896301/ /pubmed/20617188 http://dx.doi.org/10.3389/fneng.2010.00010 Text en Copyright © 2010 Jackson, Sridharan, Anand, Baker, Okandan and Muthuswamy. http://www.frontiersin.org/licenseagreement This is an open-access article subject to an exclusive license agreement between the authors and the Frontiers Research Foundation, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are credited. |
spellingShingle | Neuroscience Jackson, Nathan Sridharan, Arati Anand, Sindhu Baker, Michael Okandan, Murat Muthuswamy, Jit Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain |
title | Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain |
title_full | Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain |
title_fullStr | Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain |
title_full_unstemmed | Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain |
title_short | Long-Term Neural Recordings Using MEMS Based Movable Microelectrodes in the Brain |
title_sort | long-term neural recordings using mems based movable microelectrodes in the brain |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2896301/ https://www.ncbi.nlm.nih.gov/pubmed/20617188 http://dx.doi.org/10.3389/fneng.2010.00010 |
work_keys_str_mv | AT jacksonnathan longtermneuralrecordingsusingmemsbasedmovablemicroelectrodesinthebrain AT sridharanarati longtermneuralrecordingsusingmemsbasedmovablemicroelectrodesinthebrain AT anandsindhu longtermneuralrecordingsusingmemsbasedmovablemicroelectrodesinthebrain AT bakermichael longtermneuralrecordingsusingmemsbasedmovablemicroelectrodesinthebrain AT okandanmurat longtermneuralrecordingsusingmemsbasedmovablemicroelectrodesinthebrain AT muthuswamyjit longtermneuralrecordingsusingmemsbasedmovablemicroelectrodesinthebrain |