Cargando…

Tibial stress fracture after computer-navigated total knee arthroplasty

A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use...

Descripción completa

Detalles Bibliográficos
Autores principales: Massai, F., Conteduca, F., Vadalà, A., Iorio, R., Basiglini, L., Ferretti, A.
Formato: Texto
Lenguaje:English
Publicado: Springer International Publishing 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2896580/
https://www.ncbi.nlm.nih.gov/pubmed/20505974
http://dx.doi.org/10.1007/s10195-010-0096-9
_version_ 1782183366904250368
author Massai, F.
Conteduca, F.
Vadalà, A.
Iorio, R.
Basiglini, L.
Ferretti, A.
author_facet Massai, F.
Conteduca, F.
Vadalà, A.
Iorio, R.
Basiglini, L.
Ferretti, A.
author_sort Massai, F.
collection PubMed
description A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers.
format Text
id pubmed-2896580
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-28965802010-07-29 Tibial stress fracture after computer-navigated total knee arthroplasty Massai, F. Conteduca, F. Vadalà, A. Iorio, R. Basiglini, L. Ferretti, A. J Orthop Traumatol Case Report A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers. Springer International Publishing 2010-05-27 2010-06 /pmc/articles/PMC2896580/ /pubmed/20505974 http://dx.doi.org/10.1007/s10195-010-0096-9 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Case Report
Massai, F.
Conteduca, F.
Vadalà, A.
Iorio, R.
Basiglini, L.
Ferretti, A.
Tibial stress fracture after computer-navigated total knee arthroplasty
title Tibial stress fracture after computer-navigated total knee arthroplasty
title_full Tibial stress fracture after computer-navigated total knee arthroplasty
title_fullStr Tibial stress fracture after computer-navigated total knee arthroplasty
title_full_unstemmed Tibial stress fracture after computer-navigated total knee arthroplasty
title_short Tibial stress fracture after computer-navigated total knee arthroplasty
title_sort tibial stress fracture after computer-navigated total knee arthroplasty
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2896580/
https://www.ncbi.nlm.nih.gov/pubmed/20505974
http://dx.doi.org/10.1007/s10195-010-0096-9
work_keys_str_mv AT massaif tibialstressfractureaftercomputernavigatedtotalkneearthroplasty
AT conteducaf tibialstressfractureaftercomputernavigatedtotalkneearthroplasty
AT vadalaa tibialstressfractureaftercomputernavigatedtotalkneearthroplasty
AT iorior tibialstressfractureaftercomputernavigatedtotalkneearthroplasty
AT basiglinil tibialstressfractureaftercomputernavigatedtotalkneearthroplasty
AT ferrettia tibialstressfractureaftercomputernavigatedtotalkneearthroplasty