Cargando…

K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development

Despite the continued spread of magnetic resonance imaging (MRI) methods in scientific studies and clinical diagnosis, MRI applications are mostly restricted to high-resolution modalities such as structural MRI. While perfusion MRI gives complementary information on blood flow in the brain, its redu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kornak, John, Young, Karl
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2896642/
https://www.ncbi.nlm.nih.gov/pubmed/19274427
http://dx.doi.org/10.1007/s10278-009-9184-x
_version_ 1782183374149910528
author Kornak, John
Young, Karl
author_facet Kornak, John
Young, Karl
author_sort Kornak, John
collection PubMed
description Despite the continued spread of magnetic resonance imaging (MRI) methods in scientific studies and clinical diagnosis, MRI applications are mostly restricted to high-resolution modalities such as structural MRI. While perfusion MRI gives complementary information on blood flow in the brain, its reduced resolution limits its power for detecting specific disease effects on perfusion patterns. This reduced resolution is compounded by artifacts such as partial volume effects, Gibbs ringing, and aliasing, which are caused by necessarily limited k-space sampling and the subsequent use of discrete Fourier transform (DFT) reconstruction. Here, a Bayesian modeling procedure (K-Bayes) is developed for the reconstruction of perfusion MRI. The K-Bayes approach combines a process model for the MRI signal in k-space with a Markov random field prior distribution that incorporates high-resolution segmented structural MRI information. A simulation study, described in Part I (Concepts and Applications), was performed to determine qualitative and quantitative improvements in K-Bayes reconstructed images compared with those obtained via DFT. The improvements were validated using in vivo perfusion MRI data of the human brain. The K-Bayes reconstructed images were demonstrated to provide reduced bias, increased precision, greater effect sizes, and higher resolution than those obtained using DFT.
format Text
id pubmed-2896642
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-28966422010-08-01 K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development Kornak, John Young, Karl J Digit Imaging Article Despite the continued spread of magnetic resonance imaging (MRI) methods in scientific studies and clinical diagnosis, MRI applications are mostly restricted to high-resolution modalities such as structural MRI. While perfusion MRI gives complementary information on blood flow in the brain, its reduced resolution limits its power for detecting specific disease effects on perfusion patterns. This reduced resolution is compounded by artifacts such as partial volume effects, Gibbs ringing, and aliasing, which are caused by necessarily limited k-space sampling and the subsequent use of discrete Fourier transform (DFT) reconstruction. Here, a Bayesian modeling procedure (K-Bayes) is developed for the reconstruction of perfusion MRI. The K-Bayes approach combines a process model for the MRI signal in k-space with a Markov random field prior distribution that incorporates high-resolution segmented structural MRI information. A simulation study, described in Part I (Concepts and Applications), was performed to determine qualitative and quantitative improvements in K-Bayes reconstructed images compared with those obtained via DFT. The improvements were validated using in vivo perfusion MRI data of the human brain. The K-Bayes reconstructed images were demonstrated to provide reduced bias, increased precision, greater effect sizes, and higher resolution than those obtained using DFT. Springer-Verlag 2009-03-10 2010-08 /pmc/articles/PMC2896642/ /pubmed/19274427 http://dx.doi.org/10.1007/s10278-009-9184-x Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Article
Kornak, John
Young, Karl
K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development
title K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development
title_full K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development
title_fullStr K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development
title_full_unstemmed K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development
title_short K-Bayes Reconstruction for Perfusion MRI II: Modeling and Technical Development
title_sort k-bayes reconstruction for perfusion mri ii: modeling and technical development
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2896642/
https://www.ncbi.nlm.nih.gov/pubmed/19274427
http://dx.doi.org/10.1007/s10278-009-9184-x
work_keys_str_mv AT kornakjohn kbayesreconstructionforperfusionmriiimodelingandtechnicaldevelopment
AT youngkarl kbayesreconstructionforperfusionmriiimodelingandtechnicaldevelopment