Cargando…

Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy

Electronic portal imaging devices (EPIDs) could potentially be useful for intensity‐modulated radiation therapy (IMRT) QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters...

Descripción completa

Detalles Bibliográficos
Autores principales: Nelms, Benjamin E., Rasmussen, Karl H., Tomé, Wolfgang A.
Formato: Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2897728/
https://www.ncbi.nlm.nih.gov/pubmed/20592703
http://dx.doi.org/10.1120/jacmp.v11i2.3185
_version_ 1782183427171155968
author Nelms, Benjamin E.
Rasmussen, Karl H.
Tomé, Wolfgang A.
author_facet Nelms, Benjamin E.
Rasmussen, Karl H.
Tomé, Wolfgang A.
author_sort Nelms, Benjamin E.
collection PubMed
description Electronic portal imaging devices (EPIDs) could potentially be useful for intensity‐modulated radiation therapy (IMRT) QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in tissue equivalent media. EPIDose (Sun Nuclear, Melbourne, FL) is a tool designed for the use of EPIDs in IMRT QA that uses raw MV EPID images (no additional build‐up and independent of gantry angle, but with dark and flood field corrections applied) to estimate absolute dose planes normal to the beam axis in a homogeneous media (i.e. similar to conventional IMRT QA methods). However, because of the inherent challenges of the EPID‐based dosimetry, validating and commissioning such a system must be done very carefully, by exploring the range of use cases and using well‐proven “standards” for comparison. In this work, a multi‐institutional study was performed to verify accurate EPID image to dose plane conversion over a variety of conditions. Converted EPID images were compared to 2D diode array absolute dose measurements for 188 fields from 28 clinical IMRT treatment plans. These plans were generated using a number of commercially available treatment planning systems (TPS) covering various treatment sites including prostate, head and neck, brain, and lung. The data included three beam energies (6, 10, and 15 MV) and both step‐and‐shoot and dynamic MLC fields. Out of 26,207 points of comparison over 188 fields analyzed, the average overall field pass rate was 99.7% when [Formula: see text] DTA criteria were used (range 94.0–100 per field). The pass rates for more stringent criteria were 97.8% for [Formula: see text] DTA (range 82.0–100 per field), and 84.6% for [Formula: see text] DTA (range 54.7–100 per field). Individual patient‐specific sites as well, as different beam energies, followed similar trends to the overall pass rates. PACS number: 87.53.Dq; 87.66.Jj
format Text
id pubmed-2897728
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-28977282018-04-02 Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy Nelms, Benjamin E. Rasmussen, Karl H. Tomé, Wolfgang A. J Appl Clin Med Phys Radiation Oncology Physics Electronic portal imaging devices (EPIDs) could potentially be useful for intensity‐modulated radiation therapy (IMRT) QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in tissue equivalent media. EPIDose (Sun Nuclear, Melbourne, FL) is a tool designed for the use of EPIDs in IMRT QA that uses raw MV EPID images (no additional build‐up and independent of gantry angle, but with dark and flood field corrections applied) to estimate absolute dose planes normal to the beam axis in a homogeneous media (i.e. similar to conventional IMRT QA methods). However, because of the inherent challenges of the EPID‐based dosimetry, validating and commissioning such a system must be done very carefully, by exploring the range of use cases and using well‐proven “standards” for comparison. In this work, a multi‐institutional study was performed to verify accurate EPID image to dose plane conversion over a variety of conditions. Converted EPID images were compared to 2D diode array absolute dose measurements for 188 fields from 28 clinical IMRT treatment plans. These plans were generated using a number of commercially available treatment planning systems (TPS) covering various treatment sites including prostate, head and neck, brain, and lung. The data included three beam energies (6, 10, and 15 MV) and both step‐and‐shoot and dynamic MLC fields. Out of 26,207 points of comparison over 188 fields analyzed, the average overall field pass rate was 99.7% when [Formula: see text] DTA criteria were used (range 94.0–100 per field). The pass rates for more stringent criteria were 97.8% for [Formula: see text] DTA (range 82.0–100 per field), and 84.6% for [Formula: see text] DTA (range 54.7–100 per field). Individual patient‐specific sites as well, as different beam energies, followed similar trends to the overall pass rates. PACS number: 87.53.Dq; 87.66.Jj John Wiley and Sons Inc. 2010-04-19 /pmc/articles/PMC2897728/ /pubmed/20592703 http://dx.doi.org/10.1120/jacmp.v11i2.3185 Text en © 2010 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Nelms, Benjamin E.
Rasmussen, Karl H.
Tomé, Wolfgang A.
Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
title Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
title_full Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
title_fullStr Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
title_full_unstemmed Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
title_short Evaluation of a fast method of EPID‐based dosimetry for intensity‐modulated radiation therapy
title_sort evaluation of a fast method of epid‐based dosimetry for intensity‐modulated radiation therapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2897728/
https://www.ncbi.nlm.nih.gov/pubmed/20592703
http://dx.doi.org/10.1120/jacmp.v11i2.3185
work_keys_str_mv AT nelmsbenjamine evaluationofafastmethodofepidbaseddosimetryforintensitymodulatedradiationtherapy
AT rasmussenkarlh evaluationofafastmethodofepidbaseddosimetryforintensitymodulatedradiationtherapy
AT tomewolfganga evaluationofafastmethodofepidbaseddosimetryforintensitymodulatedradiationtherapy