Cargando…

The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation

BACKGROUND: When used during extracorporeal membrane oxygenation (ECMO), jugular venous bulb catheters, known as cephalad cannulae, increase venous drainage, augment circuit flow and decompress cerebral venous pressure. Optimized cerebral oxygen delivery during ECMO may contribute to a reduction in...

Descripción completa

Detalles Bibliográficos
Autores principales: Pettignano, Robert, Labuz, Michele, Gauthier, Theresa W, Huckaby, Jeryl, Clark, Reese H
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 1997
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC28993/
https://www.ncbi.nlm.nih.gov/pubmed/11056701
_version_ 1782119940086562816
author Pettignano, Robert
Labuz, Michele
Gauthier, Theresa W
Huckaby, Jeryl
Clark, Reese H
author_facet Pettignano, Robert
Labuz, Michele
Gauthier, Theresa W
Huckaby, Jeryl
Clark, Reese H
author_sort Pettignano, Robert
collection PubMed
description BACKGROUND: When used during extracorporeal membrane oxygenation (ECMO), jugular venous bulb catheters, known as cephalad cannulae, increase venous drainage, augment circuit flow and decompress cerebral venous pressure. Optimized cerebral oxygen delivery during ECMO may contribute to a reduction in neurological morbidity. This study describes the use of cephalad cannulae and identifies rudimentary data for jugular venous oxygen saturation (JVO(2)) and arterial to jugular venous oxygen saturation difference (AVDO(2)) in this patient population. RESULTS: Patients on venoarterial (VA) ECMO displayed higher JVO(2) (P < 0.01) and lower AVDO(2) (P = 0.01) than patients on venovenous (VV) ECMO (P < 0.01). During VV ECMO, JVO(2) was higher and AVDO(2) lower when systemic pH was < 7.35 rather than > 7.4 (P = 0.01). During VA ECMO, similar differences in AVDO(2) but not in JVO(2) were observed at different pH levels (P = 0.01). CONCLUSIONS: Jugular venous saturation and AVDO(2) were influenced by systemic pH, ECMO type and patient age. These data provide the foundation for normative values of JVO(2) and AVDO(2) in neonates and children treated with ECMO.
format Text
id pubmed-28993
institution National Center for Biotechnology Information
language English
publishDate 1997
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-289932001-03-22 The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation Pettignano, Robert Labuz, Michele Gauthier, Theresa W Huckaby, Jeryl Clark, Reese H Crit Care Research Paper BACKGROUND: When used during extracorporeal membrane oxygenation (ECMO), jugular venous bulb catheters, known as cephalad cannulae, increase venous drainage, augment circuit flow and decompress cerebral venous pressure. Optimized cerebral oxygen delivery during ECMO may contribute to a reduction in neurological morbidity. This study describes the use of cephalad cannulae and identifies rudimentary data for jugular venous oxygen saturation (JVO(2)) and arterial to jugular venous oxygen saturation difference (AVDO(2)) in this patient population. RESULTS: Patients on venoarterial (VA) ECMO displayed higher JVO(2) (P < 0.01) and lower AVDO(2) (P = 0.01) than patients on venovenous (VV) ECMO (P < 0.01). During VV ECMO, JVO(2) was higher and AVDO(2) lower when systemic pH was < 7.35 rather than > 7.4 (P = 0.01). During VA ECMO, similar differences in AVDO(2) but not in JVO(2) were observed at different pH levels (P = 0.01). CONCLUSIONS: Jugular venous saturation and AVDO(2) were influenced by systemic pH, ECMO type and patient age. These data provide the foundation for normative values of JVO(2) and AVDO(2) in neonates and children treated with ECMO. BioMed Central 1997 1998-01-22 /pmc/articles/PMC28993/ /pubmed/11056701 Text en Copyright © 1997 Current Science Limited
spellingShingle Research Paper
Pettignano, Robert
Labuz, Michele
Gauthier, Theresa W
Huckaby, Jeryl
Clark, Reese H
The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
title The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
title_full The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
title_fullStr The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
title_full_unstemmed The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
title_short The use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
title_sort use of cephalad cannulae to monitor jugular venous oxygen content during extracorporeal membrane oxygenation
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC28993/
https://www.ncbi.nlm.nih.gov/pubmed/11056701
work_keys_str_mv AT pettignanorobert theuseofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT labuzmichele theuseofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT gauthiertheresaw theuseofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT huckabyjeryl theuseofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT clarkreeseh theuseofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT pettignanorobert useofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT labuzmichele useofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT gauthiertheresaw useofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT huckabyjeryl useofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation
AT clarkreeseh useofcephaladcannulaetomonitorjugularvenousoxygencontentduringextracorporealmembraneoxygenation