Cargando…

Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient

BACKGROUND: We evaluated the effect on the respiratory gas exchange of the 30° head-down position and the complete covering of the face by sterile drapes. These are used to cannulate the internal jugular vein and position the pulmonary artery catheter in the cardiosurgical patient. During the two ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Bertolissi, Massimo, Bassi, Flavio, Silvestre, Adriana Di, Giordano, Francesco
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC29019/
https://www.ncbi.nlm.nih.gov/pubmed/11056729
_version_ 1782119946619191296
author Bertolissi, Massimo
Bassi, Flavio
Silvestre, Adriana Di
Giordano, Francesco
author_facet Bertolissi, Massimo
Bassi, Flavio
Silvestre, Adriana Di
Giordano, Francesco
author_sort Bertolissi, Massimo
collection PubMed
description BACKGROUND: We evaluated the effect on the respiratory gas exchange of the 30° head-down position and the complete covering of the face by sterile drapes. These are used to cannulate the internal jugular vein and position the pulmonary artery catheter in the cardiosurgical patient. During the two manoeuvres, 20 coronary patients and 10 patients with end-stage heart disease were supplied with oxygen (F(i)O(2) =0.4) by a Venturi mask, while 20 coronary patients breathed room air. The arterial blood samples to measure oxygen (PaO(2)) and carbon dioxide (PaCO(2)) tension and oxygen saturation (SaO(2)) were analysed by a blood gas system. RESULTS: The contemporary application of the head-down position and the drapes over the face significantly increased PaO(2) and SaO(2) in all the patientssupplied with oxygen. Without the head-down position, leaving the drapes over the face, did not significantly change the two parameters in the coronary patients supplied with oxygen, but induced a significant increase in PaO(2) and SaO(2) in the patients with end-stage heart disease. In the coronary patients that were breathing room air, PaO(2) and SaO(2) were stable throughout the study. CONCLUSIONS: We conclude that the 30° head-down position and the complete covering of the face by drapes does not interfere with respiratory gas exchange and can be safely performed in coronary patients supplied with oxygen or breathing room air and in patients with end-stage heart disease supplied with oxygen (F(i)O(2) of 0.4).
format Text
id pubmed-29019
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-290192001-03-22 Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient Bertolissi, Massimo Bassi, Flavio Silvestre, Adriana Di Giordano, Francesco Crit Care Research Paper BACKGROUND: We evaluated the effect on the respiratory gas exchange of the 30° head-down position and the complete covering of the face by sterile drapes. These are used to cannulate the internal jugular vein and position the pulmonary artery catheter in the cardiosurgical patient. During the two manoeuvres, 20 coronary patients and 10 patients with end-stage heart disease were supplied with oxygen (F(i)O(2) =0.4) by a Venturi mask, while 20 coronary patients breathed room air. The arterial blood samples to measure oxygen (PaO(2)) and carbon dioxide (PaCO(2)) tension and oxygen saturation (SaO(2)) were analysed by a blood gas system. RESULTS: The contemporary application of the head-down position and the drapes over the face significantly increased PaO(2) and SaO(2) in all the patientssupplied with oxygen. Without the head-down position, leaving the drapes over the face, did not significantly change the two parameters in the coronary patients supplied with oxygen, but induced a significant increase in PaO(2) and SaO(2) in the patients with end-stage heart disease. In the coronary patients that were breathing room air, PaO(2) and SaO(2) were stable throughout the study. CONCLUSIONS: We conclude that the 30° head-down position and the complete covering of the face by drapes does not interfere with respiratory gas exchange and can be safely performed in coronary patients supplied with oxygen or breathing room air and in patients with end-stage heart disease supplied with oxygen (F(i)O(2) of 0.4). BioMed Central 1999 1999-06-25 /pmc/articles/PMC29019/ /pubmed/11056729 Text en Copyright © 1999 Current Science Ltd
spellingShingle Research Paper
Bertolissi, Massimo
Bassi, Flavio
Silvestre, Adriana Di
Giordano, Francesco
Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
title Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
title_full Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
title_fullStr Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
title_full_unstemmed Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
title_short Effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
title_sort effects on respiratory function of the head-down position and the complete covering of the face by drapes during insertion of the monitoring catheters in the cardiosurgical patient
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC29019/
https://www.ncbi.nlm.nih.gov/pubmed/11056729
work_keys_str_mv AT bertolissimassimo effectsonrespiratoryfunctionoftheheaddownpositionandthecompletecoveringofthefacebydrapesduringinsertionofthemonitoringcathetersinthecardiosurgicalpatient
AT bassiflavio effectsonrespiratoryfunctionoftheheaddownpositionandthecompletecoveringofthefacebydrapesduringinsertionofthemonitoringcathetersinthecardiosurgicalpatient
AT silvestreadrianadi effectsonrespiratoryfunctionoftheheaddownpositionandthecompletecoveringofthefacebydrapesduringinsertionofthemonitoringcathetersinthecardiosurgicalpatient
AT giordanofrancesco effectsonrespiratoryfunctionoftheheaddownpositionandthecompletecoveringofthefacebydrapesduringinsertionofthemonitoringcathetersinthecardiosurgicalpatient