Cargando…

Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model

BACKGROUND: The Portex Soft Seal high-volume, low-pressure cuffed tracheal tube was compared with the Mallinckrodt HiLo, Sheridan Preformed and Portex Profile tracheal tubes for leakage of dye placed in the subglottic space of a pig's trachea which was used in a benchtop mechanical ventilation...

Descripción completa

Detalles Bibliográficos
Autores principales: Young, Peter J, Blunt, Mark C
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 1999
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC29025/
https://www.ncbi.nlm.nih.gov/pubmed/11056735
_version_ 1782119948150112256
author Young, Peter J
Blunt, Mark C
author_facet Young, Peter J
Blunt, Mark C
author_sort Young, Peter J
collection PubMed
description BACKGROUND: The Portex Soft Seal high-volume, low-pressure cuffed tracheal tube was compared with the Mallinckrodt HiLo, Sheridan Preformed and Portex Profile tracheal tubes for leakage of dye placed in the subglottic space of a pig's trachea which was used in a benchtop mechanical ventilation model and in six isolated pig tracheas. RESULTS: There was no leakage, either in the ventilation model or in the isolated tracheas in the Portex Soft Seal group. There was rapid leakage in the ventilation model and in all the isolated tracheas for the Mallinckrodt HiLo, and five out of six isolated tracheas for the Sheridan Preformed and the Portex Profile group. CONCLUSIONS: This benchtop study suggests that the improved compliance characteristics of the Portex Soft Seal cuff are beneficial in preventing leakage of fluid in these models.
format Text
id pubmed-29025
institution National Center for Biotechnology Information
language English
publishDate 1999
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-290252001-03-22 Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model Young, Peter J Blunt, Mark C Crit Care Research Paper BACKGROUND: The Portex Soft Seal high-volume, low-pressure cuffed tracheal tube was compared with the Mallinckrodt HiLo, Sheridan Preformed and Portex Profile tracheal tubes for leakage of dye placed in the subglottic space of a pig's trachea which was used in a benchtop mechanical ventilation model and in six isolated pig tracheas. RESULTS: There was no leakage, either in the ventilation model or in the isolated tracheas in the Portex Soft Seal group. There was rapid leakage in the ventilation model and in all the isolated tracheas for the Mallinckrodt HiLo, and five out of six isolated tracheas for the Sheridan Preformed and the Portex Profile group. CONCLUSIONS: This benchtop study suggests that the improved compliance characteristics of the Portex Soft Seal cuff are beneficial in preventing leakage of fluid in these models. BioMed Central 1999 1999-08-31 /pmc/articles/PMC29025/ /pubmed/11056735 Text en Copyright © 1999 Current Science Ltd
spellingShingle Research Paper
Young, Peter J
Blunt, Mark C
Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model
title Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model
title_full Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model
title_fullStr Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model
title_full_unstemmed Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model
title_short Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model
title_sort compliance characteristics of the portex soft seal cuff improves seal against leakage of fluid in a pig trachea model
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC29025/
https://www.ncbi.nlm.nih.gov/pubmed/11056735
work_keys_str_mv AT youngpeterj compliancecharacteristicsoftheportexsoftsealcuffimprovessealagainstleakageoffluidinapigtracheamodel
AT bluntmarkc compliancecharacteristicsoftheportexsoftsealcuffimprovessealagainstleakageoffluidinapigtracheamodel