Cargando…
Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
AIM: To assess the functional outcome following internal fixation with the PHILOS (proximal humeral interlocking system) for displaced proximal humeral fractures. PATIENTS AND METHODS: We reviewed 30 consecutive patients treated surgically with the proximal humeral locking plate for a displaced prox...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2907001/ https://www.ncbi.nlm.nih.gov/pubmed/20671866 http://dx.doi.org/10.4103/0973-6042.59971 |
_version_ | 1782184070248136704 |
---|---|
author | Thyagarajan, David S. Haridas, Samarth J. Jones, Denise Dent, Colin Evans, Richard Williams, Rhys |
author_facet | Thyagarajan, David S. Haridas, Samarth J. Jones, Denise Dent, Colin Evans, Richard Williams, Rhys |
author_sort | Thyagarajan, David S. |
collection | PubMed |
description | AIM: To assess the functional outcome following internal fixation with the PHILOS (proximal humeral interlocking system) for displaced proximal humeral fractures. PATIENTS AND METHODS: We reviewed 30 consecutive patients treated surgically with the proximal humeral locking plate for a displaced proximal humeral fracture. Functional outcome was determined using the American Shoulder and Elbow Society (ASES) score and Constant Murley score. RESULTS: Average age of the patients was 58 years (range, 19-92 years). The average overall ASES score was 66.5. The average overall Constant score was 57.5. CONCLUSION: Our results show that good fracture stability was achieved, and the functional outcome was very good in younger patients and it declined with increasing age. Early mobilization of the shoulder can be achieved without compromising fracture union. |
format | Text |
id | pubmed-2907001 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-29070012010-07-29 Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures Thyagarajan, David S. Haridas, Samarth J. Jones, Denise Dent, Colin Evans, Richard Williams, Rhys Int J Shoulder Surg Original Article AIM: To assess the functional outcome following internal fixation with the PHILOS (proximal humeral interlocking system) for displaced proximal humeral fractures. PATIENTS AND METHODS: We reviewed 30 consecutive patients treated surgically with the proximal humeral locking plate for a displaced proximal humeral fracture. Functional outcome was determined using the American Shoulder and Elbow Society (ASES) score and Constant Murley score. RESULTS: Average age of the patients was 58 years (range, 19-92 years). The average overall ASES score was 66.5. The average overall Constant score was 57.5. CONCLUSION: Our results show that good fracture stability was achieved, and the functional outcome was very good in younger patients and it declined with increasing age. Early mobilization of the shoulder can be achieved without compromising fracture union. Medknow Publications 2009 /pmc/articles/PMC2907001/ /pubmed/20671866 http://dx.doi.org/10.4103/0973-6042.59971 Text en © International Journal of Shoulder Surgery http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Thyagarajan, David S. Haridas, Samarth J. Jones, Denise Dent, Colin Evans, Richard Williams, Rhys Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
title | Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
title_full | Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
title_fullStr | Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
title_full_unstemmed | Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
title_short | Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
title_sort | functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2907001/ https://www.ncbi.nlm.nih.gov/pubmed/20671866 http://dx.doi.org/10.4103/0973-6042.59971 |
work_keys_str_mv | AT thyagarajandavids functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures AT haridassamarthj functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures AT jonesdenise functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures AT dentcolin functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures AT evansrichard functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures AT williamsrhys functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures |