Cargando…

Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures

AIM: To assess the functional outcome following internal fixation with the PHILOS (proximal humeral interlocking system) for displaced proximal humeral fractures. PATIENTS AND METHODS: We reviewed 30 consecutive patients treated surgically with the proximal humeral locking plate for a displaced prox...

Descripción completa

Detalles Bibliográficos
Autores principales: Thyagarajan, David S., Haridas, Samarth J., Jones, Denise, Dent, Colin, Evans, Richard, Williams, Rhys
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2907001/
https://www.ncbi.nlm.nih.gov/pubmed/20671866
http://dx.doi.org/10.4103/0973-6042.59971
_version_ 1782184070248136704
author Thyagarajan, David S.
Haridas, Samarth J.
Jones, Denise
Dent, Colin
Evans, Richard
Williams, Rhys
author_facet Thyagarajan, David S.
Haridas, Samarth J.
Jones, Denise
Dent, Colin
Evans, Richard
Williams, Rhys
author_sort Thyagarajan, David S.
collection PubMed
description AIM: To assess the functional outcome following internal fixation with the PHILOS (proximal humeral interlocking system) for displaced proximal humeral fractures. PATIENTS AND METHODS: We reviewed 30 consecutive patients treated surgically with the proximal humeral locking plate for a displaced proximal humeral fracture. Functional outcome was determined using the American Shoulder and Elbow Society (ASES) score and Constant Murley score. RESULTS: Average age of the patients was 58 years (range, 19-92 years). The average overall ASES score was 66.5. The average overall Constant score was 57.5. CONCLUSION: Our results show that good fracture stability was achieved, and the functional outcome was very good in younger patients and it declined with increasing age. Early mobilization of the shoulder can be achieved without compromising fracture union.
format Text
id pubmed-2907001
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-29070012010-07-29 Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures Thyagarajan, David S. Haridas, Samarth J. Jones, Denise Dent, Colin Evans, Richard Williams, Rhys Int J Shoulder Surg Original Article AIM: To assess the functional outcome following internal fixation with the PHILOS (proximal humeral interlocking system) for displaced proximal humeral fractures. PATIENTS AND METHODS: We reviewed 30 consecutive patients treated surgically with the proximal humeral locking plate for a displaced proximal humeral fracture. Functional outcome was determined using the American Shoulder and Elbow Society (ASES) score and Constant Murley score. RESULTS: Average age of the patients was 58 years (range, 19-92 years). The average overall ASES score was 66.5. The average overall Constant score was 57.5. CONCLUSION: Our results show that good fracture stability was achieved, and the functional outcome was very good in younger patients and it declined with increasing age. Early mobilization of the shoulder can be achieved without compromising fracture union. Medknow Publications 2009 /pmc/articles/PMC2907001/ /pubmed/20671866 http://dx.doi.org/10.4103/0973-6042.59971 Text en © International Journal of Shoulder Surgery http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Thyagarajan, David S.
Haridas, Samarth J.
Jones, Denise
Dent, Colin
Evans, Richard
Williams, Rhys
Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
title Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
title_full Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
title_fullStr Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
title_full_unstemmed Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
title_short Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
title_sort functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2907001/
https://www.ncbi.nlm.nih.gov/pubmed/20671866
http://dx.doi.org/10.4103/0973-6042.59971
work_keys_str_mv AT thyagarajandavids functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures
AT haridassamarthj functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures
AT jonesdenise functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures
AT dentcolin functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures
AT evansrichard functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures
AT williamsrhys functionaloutcomefollowingproximalhumeralinterlockingsystemplatingfordisplacedproximalhumeralfractures