Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC
PURPOSE: To compare quantitative polarimetric measurements in eyes with NTG and HTG using GDx-VCC. Both groups were matched by age and glaucoma stage based on the Humphrey visual field test. METHODS: We retrospectively reviewed the records of 146 patients who underwent Humphrey field analysis (HFA)...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Ophthalmological Society
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2908813/ https://www.ncbi.nlm.nih.gov/pubmed/16768187 http://dx.doi.org/10.3341/kjo.2006.20.1.26 |
_version_ | 1782184239972745216 |
---|---|
author | Jung, Ji Yong Kim, Jae-hyung Kook, Michael S. |
author_facet | Jung, Ji Yong Kim, Jae-hyung Kook, Michael S. |
author_sort | Jung, Ji Yong |
collection | PubMed |
description | PURPOSE: To compare quantitative polarimetric measurements in eyes with NTG and HTG using GDx-VCC. Both groups were matched by age and glaucoma stage based on the Humphrey visual field test. METHODS: We retrospectively reviewed the records of 146 patients who underwent Humphrey field analysis (HFA) and GDx-VCC. We compared outcomes of retinal nerve fiber layer (RNFL) parameters among the three groups by ANOVA and between each pair of groups using the Tukey-Kramer Post-Hoc test. We also evaluated the sensitivity and specificity of GDx-VCC in detecting glaucoma in each group. RESULTS: The mean age and HFA mean deviation (MD) were 55.6±9.5 years and -0.8±1.5 dB in 47 control patients, 59.4±9.0 years and -5.77±4.38 dB in 49 NTG patients, and 59.4±11.7 years and -8.09±6.77 dB in 51 HTG patients, respectively. All thickness parameters were lower in HTG patients compared to NTG patients, but there were no significant differences in ratio parameters between age-matched early HTG and NTG patients. The sensitivity of GDx-VCC was significantly higher in both early and total HTG patients compared to the respective groups of NTG patients. CONCLUSIONS: Compared to eyes with NTG, eyes with HTG showed reduced RNFL thickness and ratio parameters when patients were age and visual field matched. GDx-VCC appeared to be more sensitive in detecting RNFL damage in HTG patients. |
format | Text |
id | pubmed-2908813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | The Korean Ophthalmological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-29088132010-07-28 Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC Jung, Ji Yong Kim, Jae-hyung Kook, Michael S. Korean J Ophthalmol Original Article PURPOSE: To compare quantitative polarimetric measurements in eyes with NTG and HTG using GDx-VCC. Both groups were matched by age and glaucoma stage based on the Humphrey visual field test. METHODS: We retrospectively reviewed the records of 146 patients who underwent Humphrey field analysis (HFA) and GDx-VCC. We compared outcomes of retinal nerve fiber layer (RNFL) parameters among the three groups by ANOVA and between each pair of groups using the Tukey-Kramer Post-Hoc test. We also evaluated the sensitivity and specificity of GDx-VCC in detecting glaucoma in each group. RESULTS: The mean age and HFA mean deviation (MD) were 55.6±9.5 years and -0.8±1.5 dB in 47 control patients, 59.4±9.0 years and -5.77±4.38 dB in 49 NTG patients, and 59.4±11.7 years and -8.09±6.77 dB in 51 HTG patients, respectively. All thickness parameters were lower in HTG patients compared to NTG patients, but there were no significant differences in ratio parameters between age-matched early HTG and NTG patients. The sensitivity of GDx-VCC was significantly higher in both early and total HTG patients compared to the respective groups of NTG patients. CONCLUSIONS: Compared to eyes with NTG, eyes with HTG showed reduced RNFL thickness and ratio parameters when patients were age and visual field matched. GDx-VCC appeared to be more sensitive in detecting RNFL damage in HTG patients. The Korean Ophthalmological Society 2006-03 2006-03-31 /pmc/articles/PMC2908813/ /pubmed/16768187 http://dx.doi.org/10.3341/kjo.2006.20.1.26 Text en Copyright © 2006 by the Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Jung, Ji Yong Kim, Jae-hyung Kook, Michael S. Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC |
title | Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC |
title_full | Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC |
title_fullStr | Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC |
title_full_unstemmed | Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC |
title_short | Comparison of Retinal Nerve Fiber Layer Measurements between NTG and HTG using GDx-VCC |
title_sort | comparison of retinal nerve fiber layer measurements between ntg and htg using gdx-vcc |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2908813/ https://www.ncbi.nlm.nih.gov/pubmed/16768187 http://dx.doi.org/10.3341/kjo.2006.20.1.26 |
work_keys_str_mv | AT jungjiyong comparisonofretinalnervefiberlayermeasurementsbetweenntgandhtgusinggdxvcc AT kimjaehyung comparisonofretinalnervefiberlayermeasurementsbetweenntgandhtgusinggdxvcc AT kookmichaels comparisonofretinalnervefiberlayermeasurementsbetweenntgandhtgusinggdxvcc |