Cargando…

Video-Assisted Thoracoscopic Surgery for Correction of Adolescent Idiopatic Scoliosis: Comparison of 4.5 mm versus 5.5 mm Rod Constructs

PURPOSE: The purpose of this study is to report the comparative results of thoracoscopic correction achieved via cantilever technique using a 4.5 mm thin rod and the poly-axial reduction screw technique using a 5.5 mm thick rod in Lenke type 1 adolescent idiopathic scoliosis (AIS). MATERIALS AND MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hak Sun, Park, Jin Oh, Nanda, Ankur, Kho, Phillip Anthony, Kim, Jin Young, Lee, Hwan Mo, Moon, Seong Hwan, Ha, Jung Won, Ahn, Eun Kyoung, Shin, Dong Eun, Kim, Sung Jun, Moon, Eun Su
Formato: Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2908885/
https://www.ncbi.nlm.nih.gov/pubmed/20635452
http://dx.doi.org/10.3349/ymj.2010.51.5.753
Descripción
Sumario:PURPOSE: The purpose of this study is to report the comparative results of thoracoscopic correction achieved via cantilever technique using a 4.5 mm thin rod and the poly-axial reduction screw technique using a 5.5 mm thick rod in Lenke type 1 adolescent idiopathic scoliosis (AIS). MATERIALS AND METHODS: Radiographic data, Scoliosis Research Society (SRS) patient-based outcome questionnaires, and operative records were reviewed for forty-nine patients undergoing surgical treatment of scoliosis. The study group was divided into a 4.5 mm thin rod group (n = 24) and a 5.5 mm thick rod group (n = 25). The radiographic parameters that were analyzed included coronal curve correction, the most caudal instrumented vertebra tilt angle correction, coronal balance, and thoracic kyphosis. RESULTS: The major curve was corrected from 49.8° and 47.2° pre-operatively to 24.5° and 18.8° at the final follow-up for the thin and thick rod groups, respectively (50.8% vs. 60.2% correction). There were no significant differences between the two groups in terms of kyphosis, coronal balance, or tilt angle at the time of the final follow-up. The mean number of levels fused was 6.2 in the thin rod group, compared with 5.9 levels in the thick rod group. There were no major intraoperative complications in either group. CONCLUSION: Significant correction loss was observed in the thin rod system at the final follow-up though both groups had comparable correction immediately post-operative. Therefore, the thick rod with poly axial screw system helps to maintain post-operative correction.