Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes
BACKGROUND: The reprocessing of medical endoscopes is carried out using automatic cleaning and disinfection machines. The documentation and archiving of records of properly conducted reprocessing procedures is the last and increasingly important part of the reprocessing cycle for flexible endoscopes...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2912802/ https://www.ncbi.nlm.nih.gov/pubmed/20615248 http://dx.doi.org/10.1186/1471-230X-10-76 |
_version_ | 1782184624003219456 |
---|---|
author | Krakamp, Bernd Kirschberg, Oliver Scheding, Andreas Emmerich, Dieter Klein, Stefanie Saers, Thomas |
author_facet | Krakamp, Bernd Kirschberg, Oliver Scheding, Andreas Emmerich, Dieter Klein, Stefanie Saers, Thomas |
author_sort | Krakamp, Bernd |
collection | PubMed |
description | BACKGROUND: The reprocessing of medical endoscopes is carried out using automatic cleaning and disinfection machines. The documentation and archiving of records of properly conducted reprocessing procedures is the last and increasingly important part of the reprocessing cycle for flexible endoscopes. METHODS: This report describes a new computer program designed to monitor and document the automatic reprocessing of flexible endoscopes and accessories in fully automatic washer-disinfectors; it does not contain nor compensate the manual cleaning step. The program implements national standards for the monitoring of hygiene in flexible endoscopes and the guidelines for the reprocessing of medical products. No FDA approval has been obtained up to now. The advantages of this newly developed computer program are firstly that it simplifies the documentation procedures of medical endoscopes and that it could be used universally with any washer-disinfector and that it is independent of the various interfaces and software products provided by the individual suppliers of washer-disinfectors. RESULTS: The computer program presented here has been tested on a total of four washer-disinfectors in more than 6000 medical examinations within 9 months. CONCLUSIONS: We present for the first time an electronic documentation system for automated washer-disinfectors for medical devices e.g. flexible endoscopes which can be used on any washer-disinfectors that documents the procedures involved in the automatic cleaning process and can be easily connected to most hospital documentation systems. |
format | Text |
id | pubmed-2912802 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-29128022010-07-31 Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes Krakamp, Bernd Kirschberg, Oliver Scheding, Andreas Emmerich, Dieter Klein, Stefanie Saers, Thomas BMC Gastroenterol Technical Advance BACKGROUND: The reprocessing of medical endoscopes is carried out using automatic cleaning and disinfection machines. The documentation and archiving of records of properly conducted reprocessing procedures is the last and increasingly important part of the reprocessing cycle for flexible endoscopes. METHODS: This report describes a new computer program designed to monitor and document the automatic reprocessing of flexible endoscopes and accessories in fully automatic washer-disinfectors; it does not contain nor compensate the manual cleaning step. The program implements national standards for the monitoring of hygiene in flexible endoscopes and the guidelines for the reprocessing of medical products. No FDA approval has been obtained up to now. The advantages of this newly developed computer program are firstly that it simplifies the documentation procedures of medical endoscopes and that it could be used universally with any washer-disinfector and that it is independent of the various interfaces and software products provided by the individual suppliers of washer-disinfectors. RESULTS: The computer program presented here has been tested on a total of four washer-disinfectors in more than 6000 medical examinations within 9 months. CONCLUSIONS: We present for the first time an electronic documentation system for automated washer-disinfectors for medical devices e.g. flexible endoscopes which can be used on any washer-disinfectors that documents the procedures involved in the automatic cleaning process and can be easily connected to most hospital documentation systems. BioMed Central 2010-07-08 /pmc/articles/PMC2912802/ /pubmed/20615248 http://dx.doi.org/10.1186/1471-230X-10-76 Text en Copyright ©2010 Krakamp et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technical Advance Krakamp, Bernd Kirschberg, Oliver Scheding, Andreas Emmerich, Dieter Klein, Stefanie Saers, Thomas Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
title | Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
title_full | Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
title_fullStr | Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
title_full_unstemmed | Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
title_short | Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
title_sort | computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2912802/ https://www.ncbi.nlm.nih.gov/pubmed/20615248 http://dx.doi.org/10.1186/1471-230X-10-76 |
work_keys_str_mv | AT krakampbernd computeraidedrecordingofautomaticendoscopewashinganddisinfectionprocessesasanintegralpartofmedicaldocumentationforqualityassurancepurposes AT kirschbergoliver computeraidedrecordingofautomaticendoscopewashinganddisinfectionprocessesasanintegralpartofmedicaldocumentationforqualityassurancepurposes AT schedingandreas computeraidedrecordingofautomaticendoscopewashinganddisinfectionprocessesasanintegralpartofmedicaldocumentationforqualityassurancepurposes AT emmerichdieter computeraidedrecordingofautomaticendoscopewashinganddisinfectionprocessesasanintegralpartofmedicaldocumentationforqualityassurancepurposes AT kleinstefanie computeraidedrecordingofautomaticendoscopewashinganddisinfectionprocessesasanintegralpartofmedicaldocumentationforqualityassurancepurposes AT saersthomas computeraidedrecordingofautomaticendoscopewashinganddisinfectionprocessesasanintegralpartofmedicaldocumentationforqualityassurancepurposes |