The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty
BACKGROUND: A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2914750/ https://www.ncbi.nlm.nih.gov/pubmed/20653962 http://dx.doi.org/10.1186/1749-799X-5-45 |
_version_ | 1782184791662133248 |
---|---|
author | Lever, James P Zdero, Rad Nousiainen, Markku T Waddell, James P Schemitsch, Emil H |
author_facet | Lever, James P Zdero, Rad Nousiainen, Markku T Waddell, James P Schemitsch, Emil H |
author_sort | Lever, James P |
collection | PubMed |
description | BACKGROUND: A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty. METHODS: Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values. RESULTS: All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05). CONCLUSIONS: Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty. |
format | Text |
id | pubmed-2914750 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-29147502010-08-04 The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty Lever, James P Zdero, Rad Nousiainen, Markku T Waddell, James P Schemitsch, Emil H J Orthop Surg Res Research Article BACKGROUND: A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty. METHODS: Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values. RESULTS: All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05). CONCLUSIONS: Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty. BioMed Central 2010-07-23 /pmc/articles/PMC2914750/ /pubmed/20653962 http://dx.doi.org/10.1186/1749-799X-5-45 Text en Copyright ©2010 Lever et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Lever, James P Zdero, Rad Nousiainen, Markku T Waddell, James P Schemitsch, Emil H The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
title | The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
title_full | The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
title_fullStr | The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
title_full_unstemmed | The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
title_short | The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
title_sort | biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2914750/ https://www.ncbi.nlm.nih.gov/pubmed/20653962 http://dx.doi.org/10.1186/1749-799X-5-45 |
work_keys_str_mv | AT leverjamesp thebiomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT zderorad thebiomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT nousiainenmarkkut thebiomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT waddelljamesp thebiomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT schemitschemilh thebiomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT leverjamesp biomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT zderorad biomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT nousiainenmarkkut biomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT waddelljamesp biomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty AT schemitschemilh biomechanicalanalysisofthreeplatingfixationsystemsforperiprostheticfemoralfracturenearthetipofatotalhiparthroplasty |