Cargando…
2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series
BACKGROUND: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2916892/ https://www.ncbi.nlm.nih.gov/pubmed/20609243 http://dx.doi.org/10.1186/1471-2474-11-153 |
_version_ | 1782185029166694400 |
---|---|
author | Gras, Florian Marintschev, Ivan Wilharm, Arne Klos, Kajetan Mückley, Thomas Hofmann, Gunther O |
author_facet | Gras, Florian Marintschev, Ivan Wilharm, Arne Klos, Kajetan Mückley, Thomas Hofmann, Gunther O |
author_sort | Gras, Florian |
collection | PubMed |
description | BACKGROUND: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. METHODS: Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 ± 1.2 month. RESULTS: 56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 ± 4 minutes, mean fluoroscopy time per screw 123 ± 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. CONCLUSION: 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening. |
format | Text |
id | pubmed-2916892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-29168922010-08-06 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series Gras, Florian Marintschev, Ivan Wilharm, Arne Klos, Kajetan Mückley, Thomas Hofmann, Gunther O BMC Musculoskelet Disord Research Article BACKGROUND: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. METHODS: Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 ± 1.2 month. RESULTS: 56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 ± 4 minutes, mean fluoroscopy time per screw 123 ± 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. CONCLUSION: 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening. BioMed Central 2010-07-07 /pmc/articles/PMC2916892/ /pubmed/20609243 http://dx.doi.org/10.1186/1471-2474-11-153 Text en Copyright ©2010 Gras et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Gras, Florian Marintschev, Ivan Wilharm, Arne Klos, Kajetan Mückley, Thomas Hofmann, Gunther O 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
title | 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
title_full | 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
title_fullStr | 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
title_full_unstemmed | 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
title_short | 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
title_sort | 2d-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2916892/ https://www.ncbi.nlm.nih.gov/pubmed/20609243 http://dx.doi.org/10.1186/1471-2474-11-153 |
work_keys_str_mv | AT grasflorian 2dfluoroscopicnavigatedpercutaneousscrewfixationofpelvicringinjuriesacaseseries AT marintschevivan 2dfluoroscopicnavigatedpercutaneousscrewfixationofpelvicringinjuriesacaseseries AT wilharmarne 2dfluoroscopicnavigatedpercutaneousscrewfixationofpelvicringinjuriesacaseseries AT kloskajetan 2dfluoroscopicnavigatedpercutaneousscrewfixationofpelvicringinjuriesacaseseries AT muckleythomas 2dfluoroscopicnavigatedpercutaneousscrewfixationofpelvicringinjuriesacaseseries AT hofmanngunthero 2dfluoroscopicnavigatedpercutaneousscrewfixationofpelvicringinjuriesacaseseries |