Cargando…
Performance of High Flow Rate Samplers for Respirable Particle Collection
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(−3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collecte...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2918491/ https://www.ncbi.nlm.nih.gov/pubmed/20660144 http://dx.doi.org/10.1093/annhyg/meq050 |
_version_ | 1782185108552286208 |
---|---|
author | Lee, Taekhee Kim, Seung Won Chisholm, William P. Slaven, James Harper, Martin |
author_facet | Lee, Taekhee Kim, Seung Won Chisholm, William P. Slaven, James Harper, Martin |
author_sort | Lee, Taekhee |
collection | PubMed |
description | The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(−3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted. |
format | Text |
id | pubmed-2918491 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-29184912010-08-10 Performance of High Flow Rate Samplers for Respirable Particle Collection Lee, Taekhee Kim, Seung Won Chisholm, William P. Slaven, James Harper, Martin Ann Occup Hyg Original Articles The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(−3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted. Oxford University Press 2010-08 2010-07-21 /pmc/articles/PMC2918491/ /pubmed/20660144 http://dx.doi.org/10.1093/annhyg/meq050 Text en © The Author 2010. Published by Oxford University Press [on behalf of the British Occupational Hygiene Society]. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/2.5), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Lee, Taekhee Kim, Seung Won Chisholm, William P. Slaven, James Harper, Martin Performance of High Flow Rate Samplers for Respirable Particle Collection |
title | Performance of High Flow Rate Samplers for Respirable Particle Collection |
title_full | Performance of High Flow Rate Samplers for Respirable Particle Collection |
title_fullStr | Performance of High Flow Rate Samplers for Respirable Particle Collection |
title_full_unstemmed | Performance of High Flow Rate Samplers for Respirable Particle Collection |
title_short | Performance of High Flow Rate Samplers for Respirable Particle Collection |
title_sort | performance of high flow rate samplers for respirable particle collection |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2918491/ https://www.ncbi.nlm.nih.gov/pubmed/20660144 http://dx.doi.org/10.1093/annhyg/meq050 |
work_keys_str_mv | AT leetaekhee performanceofhighflowratesamplersforrespirableparticlecollection AT kimseungwon performanceofhighflowratesamplersforrespirableparticlecollection AT chisholmwilliamp performanceofhighflowratesamplersforrespirableparticlecollection AT slavenjames performanceofhighflowratesamplersforrespirableparticlecollection AT harpermartin performanceofhighflowratesamplersforrespirableparticlecollection |