The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints

(153)Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. (153)Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone...

Descripción completa

Detalles Bibliográficos
Autores principales: Najeeb Al Hallak, Mohammed, McCurdy, Matt, Zouain, Nicolas, Hayes, Justin
Formato: Texto
Lenguaje:English
Publicado: S. Karger AG 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2918865/
https://www.ncbi.nlm.nih.gov/pubmed/20740180
http://dx.doi.org/10.1159/000235809
_version_ 1782185157359304704
author Najeeb Al Hallak, Mohammed
McCurdy, Matt
Zouain, Nicolas
Hayes, Justin
author_facet Najeeb Al Hallak, Mohammed
McCurdy, Matt
Zouain, Nicolas
Hayes, Justin
author_sort Najeeb Al Hallak, Mohammed
collection PubMed
description (153)Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. (153)Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of (153)Sm-EDTMP leads to contamination with (154)Eu (Europium-154) [2]. A previous study only alluded to the retention of (154)Eu in the bones after receiving treatment with (153)Sm-EDTMP [2]. Activation of the alarm at security checkpoints after (153)Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received (153)Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing the American-Canadian border. We assume that the (154)Eu which remained in the patients’ bones activated the sensors. METHODS: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received (153)Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. RESULTS: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of (154)Eu emissions. CONCLUSION: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of (154)Eu retained in patients who received (153)Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of (153)Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with (153)Sm-EDTMP at Roger Maris Cancer Center receive laminated cards stating the date and the dose of treatment, as well as a statement that the holder may activate the alarm at the security checkpoints.
format Text
id pubmed-2918865
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-29188652010-08-25 The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints Najeeb Al Hallak, Mohammed McCurdy, Matt Zouain, Nicolas Hayes, Justin Case Rep Oncol Published: August 2009 (153)Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. (153)Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of (153)Sm-EDTMP leads to contamination with (154)Eu (Europium-154) [2]. A previous study only alluded to the retention of (154)Eu in the bones after receiving treatment with (153)Sm-EDTMP [2]. Activation of the alarm at security checkpoints after (153)Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received (153)Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing the American-Canadian border. We assume that the (154)Eu which remained in the patients’ bones activated the sensors. METHODS: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received (153)Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. RESULTS: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of (154)Eu emissions. CONCLUSION: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of (154)Eu retained in patients who received (153)Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of (153)Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with (153)Sm-EDTMP at Roger Maris Cancer Center receive laminated cards stating the date and the dose of treatment, as well as a statement that the holder may activate the alarm at the security checkpoints. S. Karger AG 2009-08-28 /pmc/articles/PMC2918865/ /pubmed/20740180 http://dx.doi.org/10.1159/000235809 Text en Copyright © 2009 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No-Derivative-Works License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Users may download, print and share this work on the Internet for noncommercial purposes only, provided the original work is properly cited, and a link to the original work on http://www.karger.com and the terms of this license are included in any shared versions.
spellingShingle Published: August 2009
Najeeb Al Hallak, Mohammed
McCurdy, Matt
Zouain, Nicolas
Hayes, Justin
The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
title The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
title_full The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
title_fullStr The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
title_full_unstemmed The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
title_short The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
title_sort level of europium-154 contaminating samarium-153-edtmp activates the radiation alarm system at the us homeland security checkpoints
topic Published: August 2009
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2918865/
https://www.ncbi.nlm.nih.gov/pubmed/20740180
http://dx.doi.org/10.1159/000235809
work_keys_str_mv AT najeebalhallakmohammed thelevelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT mccurdymatt thelevelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT zouainnicolas thelevelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT hayesjustin thelevelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT najeebalhallakmohammed levelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT mccurdymatt levelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT zouainnicolas levelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints
AT hayesjustin levelofeuropium154contaminatingsamarium153edtmpactivatestheradiationalarmsystemattheushomelandsecuritycheckpoints