Cargando…
Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration
BACKGROUND: In the face of costly fixation hardware with varying performance for treatment of distal humeral fractures, a novel technique (U-Frame) is proposed using conventional implants in a 180° plate arrangement. In this in-vitro study the biomechanical stability of this method was compared with...
Autores principales: | Windolf, Markus, Maza, Edgardo Ramos, Gueorguiev, Boyko, Braunstein, Volker, Schwieger, Karsten |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2921352/ https://www.ncbi.nlm.nih.gov/pubmed/20684752 http://dx.doi.org/10.1186/1471-2474-11-172 |
Ejemplares similares
-
Implant Augmentation: Adding Bone Cement to Improve the Treatment of Osteoporotic Distal Femur Fractures: A Biomechanical Study Using Human Cadaver Bones
por: Wähnert, Dirk, et al.
Publicado: (2014) -
Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware
por: Windolf, Markus, et al.
Publicado: (2010) -
Locking Plates With Computationally Enhanced Screw Trajectories Provide Superior Biomechanical Fixation Stability of Complex Proximal Humerus Fractures
por: Mischler, Dominic, et al.
Publicado: (2022) -
Statistical Morphology and Fragment Mapping of Complex Proximal Humeral Fractures
por: Mys, Karen, et al.
Publicado: (2023) -
Local bone quality measure and construct failure prediction: a biomechanical study on distal femur fractures
por: Gehweiler, Dominic, et al.
Publicado: (2021)