Cargando…
Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue
The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2925457/ https://www.ncbi.nlm.nih.gov/pubmed/20823936 |
_version_ | 1782185680660594688 |
---|---|
author | Khalifa, Yousuf M Moshirfar, Majid |
author_facet | Khalifa, Yousuf M Moshirfar, Majid |
author_sort | Khalifa, Yousuf M |
collection | PubMed |
description | The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error. |
format | Text |
id | pubmed-2925457 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-29254572010-09-03 Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue Khalifa, Yousuf M Moshirfar, Majid Clin Ophthalmol Methodology The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error. Dove Medical Press 2010 2010-08-19 /pmc/articles/PMC2925457/ /pubmed/20823936 Text en © 2010 Khalifa and Moshirfar, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Methodology Khalifa, Yousuf M Moshirfar, Majid Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue |
title | Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue |
title_full | Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue |
title_fullStr | Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue |
title_full_unstemmed | Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue |
title_short | Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue |
title_sort | improved centration of the type 1 boston keratoprosthesis in donor carrier tissue |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2925457/ https://www.ncbi.nlm.nih.gov/pubmed/20823936 |
work_keys_str_mv | AT khalifayousufm improvedcentrationofthetype1bostonkeratoprosthesisindonorcarriertissue AT moshirfarmajid improvedcentrationofthetype1bostonkeratoprosthesisindonorcarriertissue |