Cargando…
Implementing glucose control in intensive care: a multicenter trial using statistical process control
BACKGROUND: Glucose control (GC) with insulin decreases morbidity and mortality of critically ill patients. In this study we investigated GC performance over time during implementation of GC strategies within three intensive care units (ICUs) and in routine clinical practice. METHODS: All adult crit...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2926931/ https://www.ncbi.nlm.nih.gov/pubmed/20533024 http://dx.doi.org/10.1007/s00134-010-1924-3 |
Sumario: | BACKGROUND: Glucose control (GC) with insulin decreases morbidity and mortality of critically ill patients. In this study we investigated GC performance over time during implementation of GC strategies within three intensive care units (ICUs) and in routine clinical practice. METHODS: All adult critically ill patients who stayed for >24 h between 1999 and 2007 were included. Effects of implementing local GC guidelines and guideline revisions on effectiveness/efficiency-related indicators, safety-related indicators, and protocol-related indicators were measured. RESULTS: Data of 17,111 patient admissions were evaluated, with 714,141 available blood glucose levels (BGL) measurements. Mean BGL, time to reach target, hyperglycemia index, sampling frequency, percentage of hyperglycemia events, and in-range measurements statistically changed after introducing GC in all ICUs. The introduction of simple rules on GC had the largest effect. Subsequent changes in the protocol had a smaller effect than the introduction of the protocol itself. As soon as the protocol was introduced, in all ICUs the percentage of hypoglycemia events increased. Various revisions were implemented to reduce hypoglycemia events, but levels never returned to those from pre-implementation. More intensive implementation strategies including the use of a decision support system resulted in better control of the process. CONCLUSION: There are various strategies to achieve GC in routine clinical practice but with variable success. All of them were associated with an increase in hypoglycemia events, but GC was never stopped. Instead, these events have been accepted and managed. Statistical process control is a useful tool for monitoring phenomena over time and captures within-institution changes. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00134-010-1924-3) contains supplementary material, which is available to authorized users. |
---|