Cargando…

Image Quality Improvement after Implementation of a CT Accreditation Program

OBJECTIVE: The purpose of this study was to evaluate any improvement in the quality of abdominal CTs after the utilization of the nationally based accreditation program. MATERIALS AND METHODS: Approval was obtained from the Institutional Review Board, and informed consent was waived. We retrospectiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, You Sung, Jung, Seung Eun, Choi, Byung Gil, Shin, Yu Ri, Hwang, Seong Su, Ku, Young Mi, Lim, Yeon Soo, Lee, Jae Mun
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2930165/
https://www.ncbi.nlm.nih.gov/pubmed/20808700
http://dx.doi.org/10.3348/kjr.2010.11.5.553
_version_ 1782185972172062720
author Kim, You Sung
Jung, Seung Eun
Choi, Byung Gil
Shin, Yu Ri
Hwang, Seong Su
Ku, Young Mi
Lim, Yeon Soo
Lee, Jae Mun
author_facet Kim, You Sung
Jung, Seung Eun
Choi, Byung Gil
Shin, Yu Ri
Hwang, Seong Su
Ku, Young Mi
Lim, Yeon Soo
Lee, Jae Mun
author_sort Kim, You Sung
collection PubMed
description OBJECTIVE: The purpose of this study was to evaluate any improvement in the quality of abdominal CTs after the utilization of the nationally based accreditation program. MATERIALS AND METHODS: Approval was obtained from the Institutional Review Board, and informed consent was waived. We retrospectively analyzed 1,011 outside abdominal CTs, from 2003 to 2007. We evaluated images using a fill-up sheet form of the national accreditation program, and subjectively by grading for the overall CT image quality. CT scans were divided into two categories according to time periods; before and after the implementation of the accreditation program. We compared CT scans between two periods according to parameters pertaining to the evaluation of images. We determined whether there was a correlation between the results of a subjective assessment of the image quality and the evaluation scores of the clinical image. RESULTS: The following parameters were significantly different after the implementation of the accreditation program: identifying data, display parameters, scan length, spatial and contrast resolution, window width and level, optimal contrast enhancement, slice thickness, and total score. The remaining parameters were not significantly different between scans obtained from the two different periods: scan parameters, film quality, and artifacts. CONCLUSION: After performing the CT accreditation program, the quality of the outside abdominal CTs show marked improvement, especially for the parameters related to the scanning protocol.
format Text
id pubmed-2930165
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-29301652010-09-01 Image Quality Improvement after Implementation of a CT Accreditation Program Kim, You Sung Jung, Seung Eun Choi, Byung Gil Shin, Yu Ri Hwang, Seong Su Ku, Young Mi Lim, Yeon Soo Lee, Jae Mun Korean J Radiol Original Article OBJECTIVE: The purpose of this study was to evaluate any improvement in the quality of abdominal CTs after the utilization of the nationally based accreditation program. MATERIALS AND METHODS: Approval was obtained from the Institutional Review Board, and informed consent was waived. We retrospectively analyzed 1,011 outside abdominal CTs, from 2003 to 2007. We evaluated images using a fill-up sheet form of the national accreditation program, and subjectively by grading for the overall CT image quality. CT scans were divided into two categories according to time periods; before and after the implementation of the accreditation program. We compared CT scans between two periods according to parameters pertaining to the evaluation of images. We determined whether there was a correlation between the results of a subjective assessment of the image quality and the evaluation scores of the clinical image. RESULTS: The following parameters were significantly different after the implementation of the accreditation program: identifying data, display parameters, scan length, spatial and contrast resolution, window width and level, optimal contrast enhancement, slice thickness, and total score. The remaining parameters were not significantly different between scans obtained from the two different periods: scan parameters, film quality, and artifacts. CONCLUSION: After performing the CT accreditation program, the quality of the outside abdominal CTs show marked improvement, especially for the parameters related to the scanning protocol. The Korean Society of Radiology 2010 2010-08-27 /pmc/articles/PMC2930165/ /pubmed/20808700 http://dx.doi.org/10.3348/kjr.2010.11.5.553 Text en Copyright © 2010 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, You Sung
Jung, Seung Eun
Choi, Byung Gil
Shin, Yu Ri
Hwang, Seong Su
Ku, Young Mi
Lim, Yeon Soo
Lee, Jae Mun
Image Quality Improvement after Implementation of a CT Accreditation Program
title Image Quality Improvement after Implementation of a CT Accreditation Program
title_full Image Quality Improvement after Implementation of a CT Accreditation Program
title_fullStr Image Quality Improvement after Implementation of a CT Accreditation Program
title_full_unstemmed Image Quality Improvement after Implementation of a CT Accreditation Program
title_short Image Quality Improvement after Implementation of a CT Accreditation Program
title_sort image quality improvement after implementation of a ct accreditation program
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2930165/
https://www.ncbi.nlm.nih.gov/pubmed/20808700
http://dx.doi.org/10.3348/kjr.2010.11.5.553
work_keys_str_mv AT kimyousung imagequalityimprovementafterimplementationofactaccreditationprogram
AT jungseungeun imagequalityimprovementafterimplementationofactaccreditationprogram
AT choibyunggil imagequalityimprovementafterimplementationofactaccreditationprogram
AT shinyuri imagequalityimprovementafterimplementationofactaccreditationprogram
AT hwangseongsu imagequalityimprovementafterimplementationofactaccreditationprogram
AT kuyoungmi imagequalityimprovementafterimplementationofactaccreditationprogram
AT limyeonsoo imagequalityimprovementafterimplementationofactaccreditationprogram
AT leejaemun imagequalityimprovementafterimplementationofactaccreditationprogram