Cargando…

Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study

OBJECTIVE: This study aims to evaluate the effect of saliva contamination on the shear bond strength of two self-etch dentine bonding systems and also investigate the effect of decontamination procedure on the recovery of bond strength. MATERIALS AND METHODS: Sixty premolars extracted for orthodonti...

Descripción completa

Detalles Bibliográficos
Autores principales: Neelagiri, Krishna, Kundabala, M, Shashi, Rashmi A, Thomas, Manuel S, Parolia, Abhishek
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2936093/
https://www.ncbi.nlm.nih.gov/pubmed/20859478
http://dx.doi.org/10.4103/0972-0707.66714
_version_ 1782186447619489792
author Neelagiri, Krishna
Kundabala, M
Shashi, Rashmi A
Thomas, Manuel S
Parolia, Abhishek
author_facet Neelagiri, Krishna
Kundabala, M
Shashi, Rashmi A
Thomas, Manuel S
Parolia, Abhishek
author_sort Neelagiri, Krishna
collection PubMed
description OBJECTIVE: This study aims to evaluate the effect of saliva contamination on the shear bond strength of two self-etch dentine bonding systems and also investigate the effect of decontamination procedure on the recovery of bond strength. MATERIALS AND METHODS: Sixty premolars extracted for orthodontic reason were obtained and the buccal surfaces of teeth were reduced to create a flat dentine surface. The samples were randomly divided into three sub-groups for AdheSE (ASE) (Ivoclar – Vivadent, Schaan, Liechtenstein) and three sub-groups for Adper Prompt Self-Etch Adhesive (ADP) (3M ESPE, St Paul, MN, USA) of 10 each. For AdheSE (ASE); ASE-I was the control group (primer applied to fresh dentine surface), ASE-II was the contamination group (primer applied, followed by saliva contamination and then air dried) and ASE-III was the decontamination group (primer applied, followed by saliva contamination, air dried and then primer reapplied). For Adper Prompt (ADP); ADP-I was the control group (self-etch adhesive applied to fresh dentine surface), ADP-II was the contamination group (self-etch adhesive applied, followed by saliva contamination and then air dried) and ADP-III was the decontamination group (self-etch adhesive applied, followed by saliva contamination, air dried and then self-etch adhesive reapplied). Followed by the bonding procedure, a 5 mm composite resin block with Filtek P-60 (3M ESPE, St Paul, MN, USA) was built on the substrate. Shear bond strength (SBS) was tested with Instron Universal testing machine (Instron Corporation, Canton, MA, USA) with a cross head speed of 1 mm per minute. Data obtained was subjected to one way ANOVA test, while the inter group comparison was made using Tukey’s multiple comparison and Unpaired t-test. RESULTS: In AdhSE group (ASE), the sub-group ASE-II (contamination group) [5.4 ± 2.2 MPa] showed lower SBS than ASE-I [11.8 ± 2.6 MPa] and ASE-III [8.9 ± 3.3 MPa], which was statistically significant. There was no significant difference in the bond strength between the ASE-I (control group) and ASE-III (decontamination group). In Adper Prompt group (ADP), there was a severe decrease of bond strength in ADP-II (contamination group) [4.6 ± 1.1 MPa] when compared to ADP-I (control group) [7.4 ± 1.4 MPa] and ADP-III (decontamination subgroup) [14.1 ± 2.2 MPa] which was statistically significant. The bond strength of ADP-III wherein Adper Prompt bonding agent was reapplied after salivary contamination was found to be statistically significant than ADP-I and ADP-II. CONCLUSION: Saliva contamination reduces the dentine bond strength of both the self-etch systems; AdheSE and Adper Prompt. Re-application of the primer for the AdheSE and re-application of the adhesive for the Adper Prompt after air drying the saliva off can recover the dentine bond strength. In the Adper Prompt group, the added application of adhesives to decontaminate saliva not only recovered the bond strength but also improved it significantly.
format Text
id pubmed-2936093
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-29360932010-09-21 Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study Neelagiri, Krishna Kundabala, M Shashi, Rashmi A Thomas, Manuel S Parolia, Abhishek J Conserv Dent Original Article OBJECTIVE: This study aims to evaluate the effect of saliva contamination on the shear bond strength of two self-etch dentine bonding systems and also investigate the effect of decontamination procedure on the recovery of bond strength. MATERIALS AND METHODS: Sixty premolars extracted for orthodontic reason were obtained and the buccal surfaces of teeth were reduced to create a flat dentine surface. The samples were randomly divided into three sub-groups for AdheSE (ASE) (Ivoclar – Vivadent, Schaan, Liechtenstein) and three sub-groups for Adper Prompt Self-Etch Adhesive (ADP) (3M ESPE, St Paul, MN, USA) of 10 each. For AdheSE (ASE); ASE-I was the control group (primer applied to fresh dentine surface), ASE-II was the contamination group (primer applied, followed by saliva contamination and then air dried) and ASE-III was the decontamination group (primer applied, followed by saliva contamination, air dried and then primer reapplied). For Adper Prompt (ADP); ADP-I was the control group (self-etch adhesive applied to fresh dentine surface), ADP-II was the contamination group (self-etch adhesive applied, followed by saliva contamination and then air dried) and ADP-III was the decontamination group (self-etch adhesive applied, followed by saliva contamination, air dried and then self-etch adhesive reapplied). Followed by the bonding procedure, a 5 mm composite resin block with Filtek P-60 (3M ESPE, St Paul, MN, USA) was built on the substrate. Shear bond strength (SBS) was tested with Instron Universal testing machine (Instron Corporation, Canton, MA, USA) with a cross head speed of 1 mm per minute. Data obtained was subjected to one way ANOVA test, while the inter group comparison was made using Tukey’s multiple comparison and Unpaired t-test. RESULTS: In AdhSE group (ASE), the sub-group ASE-II (contamination group) [5.4 ± 2.2 MPa] showed lower SBS than ASE-I [11.8 ± 2.6 MPa] and ASE-III [8.9 ± 3.3 MPa], which was statistically significant. There was no significant difference in the bond strength between the ASE-I (control group) and ASE-III (decontamination group). In Adper Prompt group (ADP), there was a severe decrease of bond strength in ADP-II (contamination group) [4.6 ± 1.1 MPa] when compared to ADP-I (control group) [7.4 ± 1.4 MPa] and ADP-III (decontamination subgroup) [14.1 ± 2.2 MPa] which was statistically significant. The bond strength of ADP-III wherein Adper Prompt bonding agent was reapplied after salivary contamination was found to be statistically significant than ADP-I and ADP-II. CONCLUSION: Saliva contamination reduces the dentine bond strength of both the self-etch systems; AdheSE and Adper Prompt. Re-application of the primer for the AdheSE and re-application of the adhesive for the Adper Prompt after air drying the saliva off can recover the dentine bond strength. In the Adper Prompt group, the added application of adhesives to decontaminate saliva not only recovered the bond strength but also improved it significantly. Medknow Publications 2010 /pmc/articles/PMC2936093/ /pubmed/20859478 http://dx.doi.org/10.4103/0972-0707.66714 Text en © Journal of Conservative Dentistry http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Neelagiri, Krishna
Kundabala, M
Shashi, Rashmi A
Thomas, Manuel S
Parolia, Abhishek
Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
title Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
title_full Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
title_fullStr Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
title_full_unstemmed Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
title_short Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study
title_sort effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2936093/
https://www.ncbi.nlm.nih.gov/pubmed/20859478
http://dx.doi.org/10.4103/0972-0707.66714
work_keys_str_mv AT neelagirikrishna effectsofsalivacontaminationanddecontaminationproceduresonshearbondstrengthofselfetchdentinebondingsystemsaninvitrostudy
AT kundabalam effectsofsalivacontaminationanddecontaminationproceduresonshearbondstrengthofselfetchdentinebondingsystemsaninvitrostudy
AT shashirashmia effectsofsalivacontaminationanddecontaminationproceduresonshearbondstrengthofselfetchdentinebondingsystemsaninvitrostudy
AT thomasmanuels effectsofsalivacontaminationanddecontaminationproceduresonshearbondstrengthofselfetchdentinebondingsystemsaninvitrostudy
AT paroliaabhishek effectsofsalivacontaminationanddecontaminationproceduresonshearbondstrengthofselfetchdentinebondingsystemsaninvitrostudy