Cargando…

An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer

INTRODUCTION: Intensity modulated radiation therapy (IMRT) has been incorporated at several institutions for early stage laryngeal cancer (T1/T2N0M0), but its utility is controversial. METHODS: In three representative patients, multiple plans were generated: 1) Conventional 2D planning, with the pos...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomez, Daniel, Cahlon, Oren, Mechalakos, James, Lee, Nancy
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2940770/
https://www.ncbi.nlm.nih.gov/pubmed/20796303
http://dx.doi.org/10.1186/1748-717X-5-74
_version_ 1782186838355607552
author Gomez, Daniel
Cahlon, Oren
Mechalakos, James
Lee, Nancy
author_facet Gomez, Daniel
Cahlon, Oren
Mechalakos, James
Lee, Nancy
author_sort Gomez, Daniel
collection PubMed
description INTRODUCTION: Intensity modulated radiation therapy (IMRT) has been incorporated at several institutions for early stage laryngeal cancer (T1/T2N0M0), but its utility is controversial. METHODS: In three representative patients, multiple plans were generated: 1) Conventional 2D planning, with the posterior border placed at either the anterior aspect ("tight" plan) or the mid-vertebral body ("loose" plan), 2) 3D planning, utilizing both 1.0 and 0.5 cm margins for the planning target volume (PTV), and 3) IMRT planning, utilizing the same margins as the 3D plans. A dosimetric comparison was performed for the target volume, spinal cord, arytenoids, and carotid arteries. The prescription dose was 6300 cGy (225 cGy fractions), and the 3D and IMRT plans were normalized to this dose. RESULTS: For PTV margins of 1.0 cm and 0.5 cm, the D95 of the 2D tight/loose plans were 3781/5437 cGy and 5372/5869 cGy, respectively (IMRT/3D plans both 6300 cGy). With a PTV margin of 1.0 cm, the mean carotid artery dose was 2483/5671/5777/4049 cGy in the 2D tight, 2D loose, 3D, and IMRT plans, respectively. When the PTV was reduced to 0.5 cm, the the mean carotid artery dose was 2483/5671/6466/2577 cGy to the above four plans, respectively. The arytenoid doses were similar between the four plans, and spinal cord doses were well below tolerance. CONCLUSIONS: IMRT provides a more ideal dose distribution compared to 2D treatment and 3D planning in regards to mean carotid dose. We therefore recommend IMRT in select cases when the treating physician is confident with the GTV.
format Text
id pubmed-2940770
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-29407702010-09-17 An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer Gomez, Daniel Cahlon, Oren Mechalakos, James Lee, Nancy Radiat Oncol Research INTRODUCTION: Intensity modulated radiation therapy (IMRT) has been incorporated at several institutions for early stage laryngeal cancer (T1/T2N0M0), but its utility is controversial. METHODS: In three representative patients, multiple plans were generated: 1) Conventional 2D planning, with the posterior border placed at either the anterior aspect ("tight" plan) or the mid-vertebral body ("loose" plan), 2) 3D planning, utilizing both 1.0 and 0.5 cm margins for the planning target volume (PTV), and 3) IMRT planning, utilizing the same margins as the 3D plans. A dosimetric comparison was performed for the target volume, spinal cord, arytenoids, and carotid arteries. The prescription dose was 6300 cGy (225 cGy fractions), and the 3D and IMRT plans were normalized to this dose. RESULTS: For PTV margins of 1.0 cm and 0.5 cm, the D95 of the 2D tight/loose plans were 3781/5437 cGy and 5372/5869 cGy, respectively (IMRT/3D plans both 6300 cGy). With a PTV margin of 1.0 cm, the mean carotid artery dose was 2483/5671/5777/4049 cGy in the 2D tight, 2D loose, 3D, and IMRT plans, respectively. When the PTV was reduced to 0.5 cm, the the mean carotid artery dose was 2483/5671/6466/2577 cGy to the above four plans, respectively. The arytenoid doses were similar between the four plans, and spinal cord doses were well below tolerance. CONCLUSIONS: IMRT provides a more ideal dose distribution compared to 2D treatment and 3D planning in regards to mean carotid dose. We therefore recommend IMRT in select cases when the treating physician is confident with the GTV. BioMed Central 2010-08-26 /pmc/articles/PMC2940770/ /pubmed/20796303 http://dx.doi.org/10.1186/1748-717X-5-74 Text en Copyright ©2010 Gomez et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Gomez, Daniel
Cahlon, Oren
Mechalakos, James
Lee, Nancy
An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer
title An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer
title_full An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer
title_fullStr An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer
title_full_unstemmed An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer
title_short An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer
title_sort investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3d-conformal radiation therapy for early stage larynx cancer
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2940770/
https://www.ncbi.nlm.nih.gov/pubmed/20796303
http://dx.doi.org/10.1186/1748-717X-5-74
work_keys_str_mv AT gomezdaniel aninvestigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT cahlonoren aninvestigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT mechalakosjames aninvestigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT leenancy aninvestigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT gomezdaniel investigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT cahlonoren investigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT mechalakosjames investigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer
AT leenancy investigationofintensitymodulatedradiationtherapyversusconventionaltwodimensionaland3dconformalradiationtherapyforearlystagelarynxcancer