Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens

The evolution of echocardiography from 2-Dimensional Transthoracic Echo through to real time 3-Dimensional Transoesophageal Echo has enabled more accurate visualisation and quantification of valvular disorders especially prosthetic mitral valve paravalvular regurgitation. However, validation of accu...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, Martin R., Javorsky, George, Platts, David G.
Formato: Texto
Lenguaje:English
Publicado: SAGE-Hindawi Access to Research 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2945658/
https://www.ncbi.nlm.nih.gov/pubmed/20886015
http://dx.doi.org/10.4061/2010/750874
_version_ 1782187235212263424
author Brown, Martin R.
Javorsky, George
Platts, David G.
author_facet Brown, Martin R.
Javorsky, George
Platts, David G.
author_sort Brown, Martin R.
collection PubMed
description The evolution of echocardiography from 2-Dimensional Transthoracic Echo through to real time 3-Dimensional Transoesophageal Echo has enabled more accurate visualisation and quantification of valvular disorders especially prosthetic mitral valve paravalvular regurgitation. However, validation of accuracy is rarely confirmed by surgical or post-mortem specimens. We present a case directly comparing different echocardiographic modality images to post mortem specimens in a patient with prosthetic mitral valve paravalvular regurgitation.
format Text
id pubmed-2945658
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher SAGE-Hindawi Access to Research
record_format MEDLINE/PubMed
spelling pubmed-29456582010-09-30 Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens Brown, Martin R. Javorsky, George Platts, David G. Cardiol Res Pract Case Report The evolution of echocardiography from 2-Dimensional Transthoracic Echo through to real time 3-Dimensional Transoesophageal Echo has enabled more accurate visualisation and quantification of valvular disorders especially prosthetic mitral valve paravalvular regurgitation. However, validation of accuracy is rarely confirmed by surgical or post-mortem specimens. We present a case directly comparing different echocardiographic modality images to post mortem specimens in a patient with prosthetic mitral valve paravalvular regurgitation. SAGE-Hindawi Access to Research 2010-09-15 /pmc/articles/PMC2945658/ /pubmed/20886015 http://dx.doi.org/10.4061/2010/750874 Text en Copyright © 2010 Martin R. Brown et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Brown, Martin R.
Javorsky, George
Platts, David G.
Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens
title Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens
title_full Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens
title_fullStr Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens
title_full_unstemmed Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens
title_short Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens
title_sort accuracy of 3-dimensional transoesophageal echocardiography in assessment of prosthetic mitral valve dehiscence with comparison to anatomical specimens
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2945658/
https://www.ncbi.nlm.nih.gov/pubmed/20886015
http://dx.doi.org/10.4061/2010/750874
work_keys_str_mv AT brownmartinr accuracyof3dimensionaltransoesophagealechocardiographyinassessmentofprostheticmitralvalvedehiscencewithcomparisontoanatomicalspecimens
AT javorskygeorge accuracyof3dimensionaltransoesophagealechocardiographyinassessmentofprostheticmitralvalvedehiscencewithcomparisontoanatomicalspecimens
AT plattsdavidg accuracyof3dimensionaltransoesophagealechocardiographyinassessmentofprostheticmitralvalvedehiscencewithcomparisontoanatomicalspecimens