Cargando…

Direct comparison of polyethylene wear in cemented and uncemented acetabular cups

BACKGROUND: It has been indicated that, in the long term, the rate of wear and the degree of osteolysis observed with uncemented acetabular components are greater than those associated with cemented cups, but most studies which compare the wear characteristics of cementless with cemented cups have u...

Descripción completa

Detalles Bibliográficos
Autores principales: Bjerkholt, Håvard, Høvik, Øystein, Reikerås, Olav
Formato: Texto
Lenguaje:English
Publicado: Springer International Publishing 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2948124/
https://www.ncbi.nlm.nih.gov/pubmed/20811923
http://dx.doi.org/10.1007/s10195-010-0104-0
_version_ 1782187419702919168
author Bjerkholt, Håvard
Høvik, Øystein
Reikerås, Olav
author_facet Bjerkholt, Håvard
Høvik, Øystein
Reikerås, Olav
author_sort Bjerkholt, Håvard
collection PubMed
description BACKGROUND: It has been indicated that, in the long term, the rate of wear and the degree of osteolysis observed with uncemented acetabular components are greater than those associated with cemented cups, but most studies which compare the wear characteristics of cementless with cemented cups have used historical controls. We report a direct comparison of wear of a cemented and an uncemented cup with similar design, polyethylene, and sterilization method. MATERIALS AND METHODS: The study cohort includes 92 patients who were operated in 1997 with primary total hip replacement and have been followed for a period of 9–10 years. All patients were operated by posterolateral approach. In patients 70 years or older we used a cemented cup, in those 60 years or younger we used an uncemented cup, and in patients between 60 and 70 years we used either a cemented or uncemented cup as decided by the surgeon. At follow-up, radiographic imaging was obtained as standard anterioposterior view of the pelvis, and mean wear was determined as described by Livermore et al. RESULTS: The overall wear of the cemented acetabular components was 1.07 ± 0.78 mm, and that of the uncemented cups was 1.18 ± 0.61 mm (P = 0.529). Wear was significantly associated with male sex (P = 0.003), younger age (P = 0.003), and degree of inclination (P < 0.001), but wear was not significantly associated with cemented versus uncemented cup (P = 0.437). CONCLUSION: Our findings in this 9–10-year follow-up study suggest that cementless cups wear no more than cemented cups of similar design.
format Text
id pubmed-2948124
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-29481242010-10-20 Direct comparison of polyethylene wear in cemented and uncemented acetabular cups Bjerkholt, Håvard Høvik, Øystein Reikerås, Olav J Orthop Traumatol Original Article BACKGROUND: It has been indicated that, in the long term, the rate of wear and the degree of osteolysis observed with uncemented acetabular components are greater than those associated with cemented cups, but most studies which compare the wear characteristics of cementless with cemented cups have used historical controls. We report a direct comparison of wear of a cemented and an uncemented cup with similar design, polyethylene, and sterilization method. MATERIALS AND METHODS: The study cohort includes 92 patients who were operated in 1997 with primary total hip replacement and have been followed for a period of 9–10 years. All patients were operated by posterolateral approach. In patients 70 years or older we used a cemented cup, in those 60 years or younger we used an uncemented cup, and in patients between 60 and 70 years we used either a cemented or uncemented cup as decided by the surgeon. At follow-up, radiographic imaging was obtained as standard anterioposterior view of the pelvis, and mean wear was determined as described by Livermore et al. RESULTS: The overall wear of the cemented acetabular components was 1.07 ± 0.78 mm, and that of the uncemented cups was 1.18 ± 0.61 mm (P = 0.529). Wear was significantly associated with male sex (P = 0.003), younger age (P = 0.003), and degree of inclination (P < 0.001), but wear was not significantly associated with cemented versus uncemented cup (P = 0.437). CONCLUSION: Our findings in this 9–10-year follow-up study suggest that cementless cups wear no more than cemented cups of similar design. Springer International Publishing 2010-09-02 2010-09 /pmc/articles/PMC2948124/ /pubmed/20811923 http://dx.doi.org/10.1007/s10195-010-0104-0 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Original Article
Bjerkholt, Håvard
Høvik, Øystein
Reikerås, Olav
Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
title Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
title_full Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
title_fullStr Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
title_full_unstemmed Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
title_short Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
title_sort direct comparison of polyethylene wear in cemented and uncemented acetabular cups
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2948124/
https://www.ncbi.nlm.nih.gov/pubmed/20811923
http://dx.doi.org/10.1007/s10195-010-0104-0
work_keys_str_mv AT bjerkholthavard directcomparisonofpolyethylenewearincementedanduncementedacetabularcups
AT høvikøystein directcomparisonofpolyethylenewearincementedanduncementedacetabularcups
AT reikerasolav directcomparisonofpolyethylenewearincementedanduncementedacetabularcups