Needle Electrode-Based Electromechanical Reshaping of Cartilage

Electromechanical reshaping (EMR) of cartilage provides an alternative to the classic surgical techniques of modifying the shape of facial cartilages. The original embodiment of EMR required surface electrodes to be in direct contact with the entire cartilage region being reshaped. This study evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Manuel, Cyrus T., Foulad, Allen, Protsenko, Dmitriy E., Sepehr, Ali, Wong, Brian J. F.
Formato: Texto
Lenguaje:English
Publicado: Springer US 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2949569/
https://www.ncbi.nlm.nih.gov/pubmed/20614240
http://dx.doi.org/10.1007/s10439-010-0088-1
_version_ 1782187526882066432
author Manuel, Cyrus T.
Foulad, Allen
Protsenko, Dmitriy E.
Sepehr, Ali
Wong, Brian J. F.
author_facet Manuel, Cyrus T.
Foulad, Allen
Protsenko, Dmitriy E.
Sepehr, Ali
Wong, Brian J. F.
author_sort Manuel, Cyrus T.
collection PubMed
description Electromechanical reshaping (EMR) of cartilage provides an alternative to the classic surgical techniques of modifying the shape of facial cartilages. The original embodiment of EMR required surface electrodes to be in direct contact with the entire cartilage region being reshaped. This study evaluates the feasibility of using needle electrode systems for EMR of facial cartilage and evaluates the relationships between electrode configuration, voltage, and application time in effecting shape change. Flat rabbit nasal septal cartilage specimens were deformed by a jig into a 90° bend, while a constant electric voltage was applied to needle electrodes that were inserted into the cartilage. The electrode configuration, voltage (0–7.5 V), and application time (1–9 min) were varied systematically to create the most effective shape change. Electric current and temperature were measured during voltage application, and the resulting specimen shape was assessed in terms of retained bend angle. In order to demonstrate the clinical feasibility of EMR, the most effective and practical settings from the septal cartilage experimentation were used to reshape intact rabbit and pig ears ex vivo. Cell viability of the cartilage after EMR was determined using confocal microscopy in conjunction with a live/dead assay. Overall, cartilage reshaping increased with increased voltage and increased application time. For all electrode configurations and application times tested, heat generation was negligible (<1 °C) up to 6 V. At 6 V, with the most effective electrode configuration, the bend angle began to significantly increase after 2 min of application time and began to plateau above 5 min. As a function of voltage at 2 min of application time, significant reshaping occurred at and above 5 V, with no significant increase in the bend angle between 6 and 7.5 V. In conclusion, electromechanical reshaping of cartilage grafts and intact ears can be effectively performed with negligible temperature elevation and spatially limited cell injury using needle electrodes.
format Text
id pubmed-2949569
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-29495692010-10-21 Needle Electrode-Based Electromechanical Reshaping of Cartilage Manuel, Cyrus T. Foulad, Allen Protsenko, Dmitriy E. Sepehr, Ali Wong, Brian J. F. Ann Biomed Eng Article Electromechanical reshaping (EMR) of cartilage provides an alternative to the classic surgical techniques of modifying the shape of facial cartilages. The original embodiment of EMR required surface electrodes to be in direct contact with the entire cartilage region being reshaped. This study evaluates the feasibility of using needle electrode systems for EMR of facial cartilage and evaluates the relationships between electrode configuration, voltage, and application time in effecting shape change. Flat rabbit nasal septal cartilage specimens were deformed by a jig into a 90° bend, while a constant electric voltage was applied to needle electrodes that were inserted into the cartilage. The electrode configuration, voltage (0–7.5 V), and application time (1–9 min) were varied systematically to create the most effective shape change. Electric current and temperature were measured during voltage application, and the resulting specimen shape was assessed in terms of retained bend angle. In order to demonstrate the clinical feasibility of EMR, the most effective and practical settings from the septal cartilage experimentation were used to reshape intact rabbit and pig ears ex vivo. Cell viability of the cartilage after EMR was determined using confocal microscopy in conjunction with a live/dead assay. Overall, cartilage reshaping increased with increased voltage and increased application time. For all electrode configurations and application times tested, heat generation was negligible (<1 °C) up to 6 V. At 6 V, with the most effective electrode configuration, the bend angle began to significantly increase after 2 min of application time and began to plateau above 5 min. As a function of voltage at 2 min of application time, significant reshaping occurred at and above 5 V, with no significant increase in the bend angle between 6 and 7.5 V. In conclusion, electromechanical reshaping of cartilage grafts and intact ears can be effectively performed with negligible temperature elevation and spatially limited cell injury using needle electrodes. Springer US 2010-07-08 2010 /pmc/articles/PMC2949569/ /pubmed/20614240 http://dx.doi.org/10.1007/s10439-010-0088-1 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Article
Manuel, Cyrus T.
Foulad, Allen
Protsenko, Dmitriy E.
Sepehr, Ali
Wong, Brian J. F.
Needle Electrode-Based Electromechanical Reshaping of Cartilage
title Needle Electrode-Based Electromechanical Reshaping of Cartilage
title_full Needle Electrode-Based Electromechanical Reshaping of Cartilage
title_fullStr Needle Electrode-Based Electromechanical Reshaping of Cartilage
title_full_unstemmed Needle Electrode-Based Electromechanical Reshaping of Cartilage
title_short Needle Electrode-Based Electromechanical Reshaping of Cartilage
title_sort needle electrode-based electromechanical reshaping of cartilage
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2949569/
https://www.ncbi.nlm.nih.gov/pubmed/20614240
http://dx.doi.org/10.1007/s10439-010-0088-1
work_keys_str_mv AT manuelcyrust needleelectrodebasedelectromechanicalreshapingofcartilage
AT fouladallen needleelectrodebasedelectromechanicalreshapingofcartilage
AT protsenkodmitriye needleelectrodebasedelectromechanicalreshapingofcartilage
AT sepehrali needleelectrodebasedelectromechanicalreshapingofcartilage
AT wongbrianjf needleelectrodebasedelectromechanicalreshapingofcartilage