Cargando…
Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4))
In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air. Under the given co...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
German Medical Science
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2951097/ https://www.ncbi.nlm.nih.gov/pubmed/20941336 http://dx.doi.org/10.3205/dgkh000153 |
_version_ | 1782187686109380608 |
---|---|
author | Below, Harald Ryll, Sylvia Empen, Klaus Dornquast, Tina Felix, Stefan Rosenau, Heike Kramer, Sebastian Kramer, Axel |
author_facet | Below, Harald Ryll, Sylvia Empen, Klaus Dornquast, Tina Felix, Stefan Rosenau, Heike Kramer, Sebastian Kramer, Axel |
author_sort | Below, Harald |
collection | PubMed |
description | In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air. Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b. |
format | Text |
id | pubmed-2951097 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | German Medical Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-29510972010-10-12 Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) Below, Harald Ryll, Sylvia Empen, Klaus Dornquast, Tina Felix, Stefan Rosenau, Heike Kramer, Sebastian Kramer, Axel GMS Krankenhhyg Interdiszip Article In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air. Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b. German Medical Science 2010-09-21 /pmc/articles/PMC2951097/ /pubmed/20941336 http://dx.doi.org/10.3205/dgkh000153 Text en Copyright © 2010 Below et al. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-nd/3.0/deed.en). You are free to copy, distribute and transmit the work, provided the original author and source are credited. |
spellingShingle | Article Below, Harald Ryll, Sylvia Empen, Klaus Dornquast, Tina Felix, Stefan Rosenau, Heike Kramer, Sebastian Kramer, Axel Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) |
title | Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) |
title_full | Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) |
title_fullStr | Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) |
title_full_unstemmed | Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) |
title_short | Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)) |
title_sort | impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (din 1946-4)) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2951097/ https://www.ncbi.nlm.nih.gov/pubmed/20941336 http://dx.doi.org/10.3205/dgkh000153 |
work_keys_str_mv | AT belowharald impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT ryllsylvia impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT empenklaus impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT dornquasttina impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT felixstefan impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT rosenauheike impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT kramersebastian impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 AT krameraxel impactofsurfacedisinfectionandsteriledrapingoffurnitureonroomairqualityinacardiacprocedureroomwithaventilationandairconditioningsystemextrusionairflowcleanroomclass1bdin19464 |