Cargando…

Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure

The mechanical strength of the periodontal ligament (PDL) was first measured as force required to extract a tooth from its socket using human specimens. Thereafter, tooth-PDL-bone preparations have extensively been used for measurement of the mechanical response of the PDL. In vitro treatments of su...

Descripción completa

Detalles Bibliográficos
Autor principal: Komatsu, Koichiro
Formato: Texto
Lenguaje:English
Publicado: SAGE-Hindawi Access to Research 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2951112/
https://www.ncbi.nlm.nih.gov/pubmed/20948569
http://dx.doi.org/10.4061/2010/502318
_version_ 1782187689708093440
author Komatsu, Koichiro
author_facet Komatsu, Koichiro
author_sort Komatsu, Koichiro
collection PubMed
description The mechanical strength of the periodontal ligament (PDL) was first measured as force required to extract a tooth from its socket using human specimens. Thereafter, tooth-PDL-bone preparations have extensively been used for measurement of the mechanical response of the PDL. In vitro treatments of such specimens with specific enzymes allowed one to investigate into the roles of the structural components in the mechanical support of the PDL. The viscoelastic responses of the PDL may be examined by analysis of the stress-relaxation. Video polarised microscopy suggested that the collagen molecules and fibrils in the stretched fibre bundles progressively align along the deformation direction during the relaxation. The stress-relaxation process of the PDL can be well expressed by a function with three exponential decay terms. Analysis after in vitro digestion of the collagen fibres by collagenase revealed that the collagen fibre components may play an important role in the long-term relaxation component of the stress-relaxation process of the PDL. The dynamic measurements of the viscoelastic properties of the PDL have recently suggested that the PDL can absorb more energy in compression than in shear and tension. These viscoelastic mechanisms of the PDL tissue could reduce the risk of injury to the PDL.
format Text
id pubmed-2951112
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher SAGE-Hindawi Access to Research
record_format MEDLINE/PubMed
spelling pubmed-29511122010-10-14 Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure Komatsu, Koichiro J Dent Biomech Review Article The mechanical strength of the periodontal ligament (PDL) was first measured as force required to extract a tooth from its socket using human specimens. Thereafter, tooth-PDL-bone preparations have extensively been used for measurement of the mechanical response of the PDL. In vitro treatments of such specimens with specific enzymes allowed one to investigate into the roles of the structural components in the mechanical support of the PDL. The viscoelastic responses of the PDL may be examined by analysis of the stress-relaxation. Video polarised microscopy suggested that the collagen molecules and fibrils in the stretched fibre bundles progressively align along the deformation direction during the relaxation. The stress-relaxation process of the PDL can be well expressed by a function with three exponential decay terms. Analysis after in vitro digestion of the collagen fibres by collagenase revealed that the collagen fibre components may play an important role in the long-term relaxation component of the stress-relaxation process of the PDL. The dynamic measurements of the viscoelastic properties of the PDL have recently suggested that the PDL can absorb more energy in compression than in shear and tension. These viscoelastic mechanisms of the PDL tissue could reduce the risk of injury to the PDL. SAGE-Hindawi Access to Research 2009-12-15 /pmc/articles/PMC2951112/ /pubmed/20948569 http://dx.doi.org/10.4061/2010/502318 Text en Copyright © 2010 Koichiro Komatsu. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Komatsu, Koichiro
Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure
title Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure
title_full Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure
title_fullStr Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure
title_full_unstemmed Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure
title_short Mechanical Strength and Viscoelastic Response of the Periodontal Ligament in Relation to Structure
title_sort mechanical strength and viscoelastic response of the periodontal ligament in relation to structure
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2951112/
https://www.ncbi.nlm.nih.gov/pubmed/20948569
http://dx.doi.org/10.4061/2010/502318
work_keys_str_mv AT komatsukoichiro mechanicalstrengthandviscoelasticresponseoftheperiodontalligamentinrelationtostructure