Cargando…
Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Te...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952904/ https://www.ncbi.nlm.nih.gov/pubmed/20953369 http://dx.doi.org/10.1155/2010/717591 |
_version_ | 1782187824514072576 |
---|---|
author | Akaishi, Leonardo Vaz, Rodrigo Vilella, Graziela Garcez, Rodrigo C. Tzelikis, Patrick F. |
author_facet | Akaishi, Leonardo Vaz, Rodrigo Vilella, Graziela Garcez, Rodrigo C. Tzelikis, Patrick F. |
author_sort | Akaishi, Leonardo |
collection | PubMed |
description | Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract. |
format | Text |
id | pubmed-2952904 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-29529042010-10-15 Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup Akaishi, Leonardo Vaz, Rodrigo Vilella, Graziela Garcez, Rodrigo C. Tzelikis, Patrick F. J Ophthalmol Clinical Study Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract. Hindawi Publishing Corporation 2010 2010-10-05 /pmc/articles/PMC2952904/ /pubmed/20953369 http://dx.doi.org/10.1155/2010/717591 Text en Copyright © 2010 Leonardo Akaishi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Akaishi, Leonardo Vaz, Rodrigo Vilella, Graziela Garcez, Rodrigo C. Tzelikis, Patrick F. Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup |
title | Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup |
title_full | Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup |
title_fullStr | Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup |
title_full_unstemmed | Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup |
title_short | Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup |
title_sort | visual performance of tecnis zm900 diffractive multifocal iol after 2500 implants: a 3-year followup |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952904/ https://www.ncbi.nlm.nih.gov/pubmed/20953369 http://dx.doi.org/10.1155/2010/717591 |
work_keys_str_mv | AT akaishileonardo visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup AT vazrodrigo visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup AT vilellagraziela visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup AT garcezrodrigoc visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup AT tzelikispatrickf visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup |