Cargando…

Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup

Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Te...

Descripción completa

Detalles Bibliográficos
Autores principales: Akaishi, Leonardo, Vaz, Rodrigo, Vilella, Graziela, Garcez, Rodrigo C., Tzelikis, Patrick F.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952904/
https://www.ncbi.nlm.nih.gov/pubmed/20953369
http://dx.doi.org/10.1155/2010/717591
_version_ 1782187824514072576
author Akaishi, Leonardo
Vaz, Rodrigo
Vilella, Graziela
Garcez, Rodrigo C.
Tzelikis, Patrick F.
author_facet Akaishi, Leonardo
Vaz, Rodrigo
Vilella, Graziela
Garcez, Rodrigo C.
Tzelikis, Patrick F.
author_sort Akaishi, Leonardo
collection PubMed
description Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract.
format Text
id pubmed-2952904
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-29529042010-10-15 Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup Akaishi, Leonardo Vaz, Rodrigo Vilella, Graziela Garcez, Rodrigo C. Tzelikis, Patrick F. J Ophthalmol Clinical Study Purpose. To evaluate visual performance for near, intermediate, and distant vision; complaints of photic phenomena, and patient satisfaction with the new diffractive multifocal IOL used in eyes which underwent phacoemulsification. Methods. Two thousand and five hundred consecutive eyes undergoing Tecnis ZM900 multifocal IOL implantation were included in this retrospective analysis. The minimum followup of 3 months was required after the surgery. Patients were assessed for uncorrected near visual acuity (UNVA) at a fixed distance (33 cm), uncorrected intermediate visual acuity (UIVA) at 60 cm, and uncorrected distance visual acuity (UDVA). Using a subjective questionnaire, patients satisfaction, their independence from using glasses, and the perception of glare and halo phenomena were also evaluated at the last follow-up. Results. Two thousand and five hundred eyes of 1558 patients underwent cataract surgery and Tecnis ZM900 multifocal IOL implantation. Four hundred and eighty seven patients (31.3%) were men, and 1071 (68.7%) were women. The mean age of the patients was 66.17 years. A UDVA of 20/30 or better was achieved by 85% of eyes. A UNVA of J1 was achieved by 93.7% of eyes and that of J2 or better was achieved by 98%. A UIVA of J4 or better was achieved by 65% and J5 or better was achived by more than 82.8% of the eyes in the study. Glare and halos were reported as severe by only 6.1% and 2.12% of patients, respectively. Ninety seven percent reported complete spectacle independence and 88% stated that they are totally satisfied with their quality of vision and would choose to have the same lens implanted again after the first implant. Five percent of the eyes in the study needed a second procedure (enhancement) to achieve a better visual result. No patient underwent lens exchange. Conclusion. Excellent near, intermediate, and distant vision was observed in patients implanted with the Tecnis ZM900 diffractive multifocal IOL. Spectacle independence and a minimum occurrence of photic phenomena make this IOL an excellent option in patients with cataract. Hindawi Publishing Corporation 2010 2010-10-05 /pmc/articles/PMC2952904/ /pubmed/20953369 http://dx.doi.org/10.1155/2010/717591 Text en Copyright © 2010 Leonardo Akaishi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Akaishi, Leonardo
Vaz, Rodrigo
Vilella, Graziela
Garcez, Rodrigo C.
Tzelikis, Patrick F.
Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
title Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
title_full Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
title_fullStr Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
title_full_unstemmed Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
title_short Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup
title_sort visual performance of tecnis zm900 diffractive multifocal iol after 2500 implants: a 3-year followup
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952904/
https://www.ncbi.nlm.nih.gov/pubmed/20953369
http://dx.doi.org/10.1155/2010/717591
work_keys_str_mv AT akaishileonardo visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup
AT vazrodrigo visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup
AT vilellagraziela visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup
AT garcezrodrigoc visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup
AT tzelikispatrickf visualperformanceoftecniszm900diffractivemultifocaliolafter2500implantsa3yearfollowup