Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers dur...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952907/ https://www.ncbi.nlm.nih.gov/pubmed/20976260 http://dx.doi.org/10.1155/2010/654506 |
_version_ | 1782187825319378944 |
---|---|
author | Ji, Changguo van der Have, Frans Gratama van Andel, Hugo Ramakers, Ruud Beekman, Freek |
author_facet | Ji, Changguo van der Have, Frans Gratama van Andel, Hugo Ramakers, Ruud Beekman, Freek |
author_sort | Ji, Changguo |
collection | PubMed |
description | Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers during animal scanning. Methods. Transferable animal beds were developed with an accurate mounting interface. Simple calibration phantoms make it possible to obtain both the spatial transformation matrix for stitching multiple CT scans of different parts of the animal and to register SPECT and CT. The spatial transformation for image coregistration is calculated once using Horn's matching algorithm. Animal images can then be coregistered without using markers. Results. For mouse-sized objects, average coregistration errors between SPECT and CT in X, Y, and Z directions are within 0.04 mm, 0.10 mm, and 0.19 mm, respectively. For rat-sized objects, these numbers are 0.22 mm, 0.14 mm, and 0.28 mm. Average 3D coregistration errors were within 0.24 mm and 0.42 mm for mouse and rat imaging, respectively. Conclusion. Extending the field-of-view of cone-beam CT by stitching is improved by prior registration of the CT volumes. The accuracy of registration between SPECT and CT is typically better than the image resolution of current ultra-high-resolution SPECT. |
format | Text |
id | pubmed-2952907 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-29529072010-10-25 Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners Ji, Changguo van der Have, Frans Gratama van Andel, Hugo Ramakers, Ruud Beekman, Freek Int J Biomed Imaging Research Article Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers during animal scanning. Methods. Transferable animal beds were developed with an accurate mounting interface. Simple calibration phantoms make it possible to obtain both the spatial transformation matrix for stitching multiple CT scans of different parts of the animal and to register SPECT and CT. The spatial transformation for image coregistration is calculated once using Horn's matching algorithm. Animal images can then be coregistered without using markers. Results. For mouse-sized objects, average coregistration errors between SPECT and CT in X, Y, and Z directions are within 0.04 mm, 0.10 mm, and 0.19 mm, respectively. For rat-sized objects, these numbers are 0.22 mm, 0.14 mm, and 0.28 mm. Average 3D coregistration errors were within 0.24 mm and 0.42 mm for mouse and rat imaging, respectively. Conclusion. Extending the field-of-view of cone-beam CT by stitching is improved by prior registration of the CT volumes. The accuracy of registration between SPECT and CT is typically better than the image resolution of current ultra-high-resolution SPECT. Hindawi Publishing Corporation 2010 2010-10-05 /pmc/articles/PMC2952907/ /pubmed/20976260 http://dx.doi.org/10.1155/2010/654506 Text en Copyright © 2010 Changguo Ji et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ji, Changguo van der Have, Frans Gratama van Andel, Hugo Ramakers, Ruud Beekman, Freek Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners |
title | Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners |
title_full | Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners |
title_fullStr | Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners |
title_full_unstemmed | Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners |
title_short | Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners |
title_sort | accurate coregistration between ultra-high-resolution micro-spect and circular cone-beam micro-ct scanners |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952907/ https://www.ncbi.nlm.nih.gov/pubmed/20976260 http://dx.doi.org/10.1155/2010/654506 |
work_keys_str_mv | AT jichangguo accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners AT vanderhavefrans accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners AT gratamavanandelhugo accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners AT ramakersruud accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners AT beekmanfreek accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners |