Cargando…

Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners

Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers dur...

Descripción completa

Detalles Bibliográficos
Autores principales: Ji, Changguo, van der Have, Frans, Gratama van Andel, Hugo, Ramakers, Ruud, Beekman, Freek
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952907/
https://www.ncbi.nlm.nih.gov/pubmed/20976260
http://dx.doi.org/10.1155/2010/654506
_version_ 1782187825319378944
author Ji, Changguo
van der Have, Frans
Gratama van Andel, Hugo
Ramakers, Ruud
Beekman, Freek
author_facet Ji, Changguo
van der Have, Frans
Gratama van Andel, Hugo
Ramakers, Ruud
Beekman, Freek
author_sort Ji, Changguo
collection PubMed
description Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers during animal scanning. Methods. Transferable animal beds were developed with an accurate mounting interface. Simple calibration phantoms make it possible to obtain both the spatial transformation matrix for stitching multiple CT scans of different parts of the animal and to register SPECT and CT. The spatial transformation for image coregistration is calculated once using Horn's matching algorithm. Animal images can then be coregistered without using markers. Results. For mouse-sized objects, average coregistration errors between SPECT and CT in X, Y, and Z directions are within 0.04 mm, 0.10 mm, and 0.19 mm, respectively. For rat-sized objects, these numbers are 0.22 mm, 0.14 mm, and 0.28 mm. Average 3D coregistration errors were within 0.24 mm and 0.42 mm for mouse and rat imaging, respectively. Conclusion. Extending the field-of-view of cone-beam CT by stitching is improved by prior registration of the CT volumes. The accuracy of registration between SPECT and CT is typically better than the image resolution of current ultra-high-resolution SPECT.
format Text
id pubmed-2952907
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-29529072010-10-25 Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners Ji, Changguo van der Have, Frans Gratama van Andel, Hugo Ramakers, Ruud Beekman, Freek Int J Biomed Imaging Research Article Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers during animal scanning. Methods. Transferable animal beds were developed with an accurate mounting interface. Simple calibration phantoms make it possible to obtain both the spatial transformation matrix for stitching multiple CT scans of different parts of the animal and to register SPECT and CT. The spatial transformation for image coregistration is calculated once using Horn's matching algorithm. Animal images can then be coregistered without using markers. Results. For mouse-sized objects, average coregistration errors between SPECT and CT in X, Y, and Z directions are within 0.04 mm, 0.10 mm, and 0.19 mm, respectively. For rat-sized objects, these numbers are 0.22 mm, 0.14 mm, and 0.28 mm. Average 3D coregistration errors were within 0.24 mm and 0.42 mm for mouse and rat imaging, respectively. Conclusion. Extending the field-of-view of cone-beam CT by stitching is improved by prior registration of the CT volumes. The accuracy of registration between SPECT and CT is typically better than the image resolution of current ultra-high-resolution SPECT. Hindawi Publishing Corporation 2010 2010-10-05 /pmc/articles/PMC2952907/ /pubmed/20976260 http://dx.doi.org/10.1155/2010/654506 Text en Copyright © 2010 Changguo Ji et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ji, Changguo
van der Have, Frans
Gratama van Andel, Hugo
Ramakers, Ruud
Beekman, Freek
Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
title Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
title_full Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
title_fullStr Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
title_full_unstemmed Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
title_short Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners
title_sort accurate coregistration between ultra-high-resolution micro-spect and circular cone-beam micro-ct scanners
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2952907/
https://www.ncbi.nlm.nih.gov/pubmed/20976260
http://dx.doi.org/10.1155/2010/654506
work_keys_str_mv AT jichangguo accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners
AT vanderhavefrans accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners
AT gratamavanandelhugo accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners
AT ramakersruud accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners
AT beekmanfreek accuratecoregistrationbetweenultrahighresolutionmicrospectandcircularconebeammicroctscanners