Cargando…

Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets

In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and line...

Descripción completa

Detalles Bibliográficos
Autores principales: Major, Thomas W., Carey, Jason P., Nobes, David S., Major, Paul W.
Formato: Texto
Lenguaje:English
Publicado: SAGE-Hindawi Access to Research 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2958443/
https://www.ncbi.nlm.nih.gov/pubmed/20981299
http://dx.doi.org/10.4061/2010/781321
_version_ 1782188342571433984
author Major, Thomas W.
Carey, Jason P.
Nobes, David S.
Major, Paul W.
author_facet Major, Thomas W.
Carey, Jason P.
Nobes, David S.
Major, Paul W.
author_sort Major, Thomas W.
collection PubMed
description In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized.
format Text
id pubmed-2958443
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher SAGE-Hindawi Access to Research
record_format MEDLINE/PubMed
spelling pubmed-29584432010-10-27 Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets Major, Thomas W. Carey, Jason P. Nobes, David S. Major, Paul W. J Dent Biomech Research Article In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the slot's top and bottom, angles between walls, slot taper, and the linearity of each wall. Slot dimensions for 30 upper right central incisor self-ligating stainless steel brackets from three manufacturers were evaluated. Speed brackets have a slot height 2% smaller than the nominal 0.559 mm size and have a slightly convergent taper. In-Ovation brackets have a divergent taper at an average angle of 1.47 degrees. In-Ovation is closest to the nominal value of slot height at the slot base and has the smallest manufacturing tolerances. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. Damon slot height is on average 3% oversized. SAGE-Hindawi Access to Research 2010-06-27 /pmc/articles/PMC2958443/ /pubmed/20981299 http://dx.doi.org/10.4061/2010/781321 Text en Copyright © 2010 Thomas W. Major et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Major, Thomas W.
Carey, Jason P.
Nobes, David S.
Major, Paul W.
Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets
title Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets
title_full Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets
title_fullStr Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets
title_full_unstemmed Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets
title_short Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets
title_sort orthodontic bracket manufacturing tolerances and dimensional differences between select self-ligating brackets
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2958443/
https://www.ncbi.nlm.nih.gov/pubmed/20981299
http://dx.doi.org/10.4061/2010/781321
work_keys_str_mv AT majorthomasw orthodonticbracketmanufacturingtolerancesanddimensionaldifferencesbetweenselectselfligatingbrackets
AT careyjasonp orthodonticbracketmanufacturingtolerancesanddimensionaldifferencesbetweenselectselfligatingbrackets
AT nobesdavids orthodonticbracketmanufacturingtolerancesanddimensionaldifferencesbetweenselectselfligatingbrackets
AT majorpaulw orthodonticbracketmanufacturingtolerancesanddimensionaldifferencesbetweenselectselfligatingbrackets