BACKGROUND: The survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably used for patients whose vessels are unsuitable for an autogenous arteriovenous (AV) fistula. The purpose of this stu...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2971481/ https://www.ncbi.nlm.nih.gov/pubmed/20218943 http://dx.doi.org/10.3109/03009731003678562 |
_version_ | 1782190637071728640 |
---|---|
author | Ravari, Hassan Kazemzade, Gholam Hossein Modaghegh, Mohammad Hadi Saied Khashayar, Patricia |
author_facet | Ravari, Hassan Kazemzade, Gholam Hossein Modaghegh, Mohammad Hadi Saied Khashayar, Patricia |
author_sort | Ravari, Hassan |
collection | PubMed |
description | BACKGROUND: The survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably used for patients whose vessels are unsuitable for an autogenous arteriovenous (AV) fistula. The purpose of this study was to compare the patency rate and associated complications using different types of grafts. METHODS: This prospective study was conducted on patients who did not have an appropriate vein for arteriovenous fistula from January 2004 through July 2006. They were divided into two groups, sex, age, and basic data matched. Polytetrafluoroethylene (PTFE) and polyurethane (PVAG) were the two types of grafts used in this study. The functionality of the graft was assessed immediately 1 day and 2 weeks after operation. The clinical follow-up was performed each 3 months until 24 months. RESULTS: One-year patency rate was reported to be 64% and 52% in the PTFE and PVAG groups, respectively. There was no significant difference in 1-year (64% versus 52%) and 2-year (49% versus 41%) patency rate of the PTFE and PVAG grafts used as vascular access. There was also no difference between the numbers of complications reported in the two groups. CONCLUSION: It could be concluded that either PTFE or PVAG grafts can be used with the same expected outcomes. |
format | Text |
id | pubmed-2971481 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-29714812010-11-08 Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access Ravari, Hassan Kazemzade, Gholam Hossein Modaghegh, Mohammad Hadi Saied Khashayar, Patricia Ups J Med Sci Original Article BACKGROUND: The survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably used for patients whose vessels are unsuitable for an autogenous arteriovenous (AV) fistula. The purpose of this study was to compare the patency rate and associated complications using different types of grafts. METHODS: This prospective study was conducted on patients who did not have an appropriate vein for arteriovenous fistula from January 2004 through July 2006. They were divided into two groups, sex, age, and basic data matched. Polytetrafluoroethylene (PTFE) and polyurethane (PVAG) were the two types of grafts used in this study. The functionality of the graft was assessed immediately 1 day and 2 weeks after operation. The clinical follow-up was performed each 3 months until 24 months. RESULTS: One-year patency rate was reported to be 64% and 52% in the PTFE and PVAG groups, respectively. There was no significant difference in 1-year (64% versus 52%) and 2-year (49% versus 41%) patency rate of the PTFE and PVAG grafts used as vascular access. There was also no difference between the numbers of complications reported in the two groups. CONCLUSION: It could be concluded that either PTFE or PVAG grafts can be used with the same expected outcomes. Informa Healthcare 2010-10 2010-10-27 /pmc/articles/PMC2971481/ /pubmed/20218943 http://dx.doi.org/10.3109/03009731003678562 Text en © Upsala Medical Society http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Original Article Ravari, Hassan Kazemzade, Gholam Hossein Modaghegh, Mohammad Hadi Saied Khashayar, Patricia Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
title | Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
title_full | Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
title_fullStr | Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
title_full_unstemmed | Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
title_short | Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
title_sort | patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2971481/ https://www.ncbi.nlm.nih.gov/pubmed/20218943 http://dx.doi.org/10.3109/03009731003678562 |
work_keys_str_mv | AT ravarihassan patencyrateandcomplicationsofpolytetrafluoroethylenegraftscomparedwithpolyurethanegraftsforhemodialysisaccess AT kazemzadegholamhossein patencyrateandcomplicationsofpolytetrafluoroethylenegraftscomparedwithpolyurethanegraftsforhemodialysisaccess AT modagheghmohammadhadisaied patencyrateandcomplicationsofpolytetrafluoroethylenegraftscomparedwithpolyurethanegraftsforhemodialysisaccess AT khashayarpatricia patencyrateandcomplicationsofpolytetrafluoroethylenegraftscomparedwithpolyurethanegraftsforhemodialysisaccess |