Cargando…

Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation

BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which cou...

Descripción completa

Detalles Bibliográficos
Autores principales: Shahgaldi, Kambiz, Manouras, Aristomenis, Abrahamsson, Anna, Gudmundsson, Petri, Brodin, Lars-Åke, Winter, Reidar
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2972240/
https://www.ncbi.nlm.nih.gov/pubmed/20920373
http://dx.doi.org/10.1186/1476-7120-8-45
_version_ 1782190774476079104
author Shahgaldi, Kambiz
Manouras, Aristomenis
Abrahamsson, Anna
Gudmundsson, Petri
Brodin, Lars-Åke
Winter, Reidar
author_facet Shahgaldi, Kambiz
Manouras, Aristomenis
Abrahamsson, Anna
Gudmundsson, Petri
Brodin, Lars-Åke
Winter, Reidar
author_sort Shahgaldi, Kambiz
collection PubMed
description BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. METHODS: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. RESULTS: SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p < 0.001) and EF (p < 0.05) with SB in comparison to 4B in group B. CONCLUSION: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes.
format Text
id pubmed-2972240
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-29722402010-11-04 Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation Shahgaldi, Kambiz Manouras, Aristomenis Abrahamsson, Anna Gudmundsson, Petri Brodin, Lars-Åke Winter, Reidar Cardiovasc Ultrasound Research BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. METHODS: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. RESULTS: SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p < 0.001) and EF (p < 0.05) with SB in comparison to 4B in group B. CONCLUSION: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes. BioMed Central 2010-10-05 /pmc/articles/PMC2972240/ /pubmed/20920373 http://dx.doi.org/10.1186/1476-7120-8-45 Text en Copyright ©2010 Shahgaldi et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Shahgaldi, Kambiz
Manouras, Aristomenis
Abrahamsson, Anna
Gudmundsson, Petri
Brodin, Lars-Åke
Winter, Reidar
Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
title Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
title_full Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
title_fullStr Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
title_full_unstemmed Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
title_short Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
title_sort three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2972240/
https://www.ncbi.nlm.nih.gov/pubmed/20920373
http://dx.doi.org/10.1186/1476-7120-8-45
work_keys_str_mv AT shahgaldikambiz threedimensionalechocardiographyusingsingleheartbeatmodalitydecreasesvariabilityinmeasuringleftventricularvolumesandfunctionincomparisontofourbeattechniqueinatrialfibrillation
AT manourasaristomenis threedimensionalechocardiographyusingsingleheartbeatmodalitydecreasesvariabilityinmeasuringleftventricularvolumesandfunctionincomparisontofourbeattechniqueinatrialfibrillation
AT abrahamssonanna threedimensionalechocardiographyusingsingleheartbeatmodalitydecreasesvariabilityinmeasuringleftventricularvolumesandfunctionincomparisontofourbeattechniqueinatrialfibrillation
AT gudmundssonpetri threedimensionalechocardiographyusingsingleheartbeatmodalitydecreasesvariabilityinmeasuringleftventricularvolumesandfunctionincomparisontofourbeattechniqueinatrialfibrillation
AT brodinlarsake threedimensionalechocardiographyusingsingleheartbeatmodalitydecreasesvariabilityinmeasuringleftventricularvolumesandfunctionincomparisontofourbeattechniqueinatrialfibrillation
AT winterreidar threedimensionalechocardiographyusingsingleheartbeatmodalitydecreasesvariabilityinmeasuringleftventricularvolumesandfunctionincomparisontofourbeattechniqueinatrialfibrillation