Cargando…

Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study

The purpose of this study was to evaluate computed analysis of three-dimensional (3D) cone-beam computed tomography angiography (CTA) of the liver for determination of subsegmental tumor-feeding vessels (FVs). Eighteen consecutive patients underwent transarterial chemoembolization (TACE) from Januar...

Descripción completa

Detalles Bibliográficos
Autores principales: Deschamps, Frederic, Solomon, Stephen B., Thornton, Raymond H., Rao, Pramod, Hakime, Antoine, Kuoch, Viseth, de Baere, Thierry
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2977071/
https://www.ncbi.nlm.nih.gov/pubmed/20390271
http://dx.doi.org/10.1007/s00270-010-9846-6
_version_ 1782191020300042240
author Deschamps, Frederic
Solomon, Stephen B.
Thornton, Raymond H.
Rao, Pramod
Hakime, Antoine
Kuoch, Viseth
de Baere, Thierry
author_facet Deschamps, Frederic
Solomon, Stephen B.
Thornton, Raymond H.
Rao, Pramod
Hakime, Antoine
Kuoch, Viseth
de Baere, Thierry
author_sort Deschamps, Frederic
collection PubMed
description The purpose of this study was to evaluate computed analysis of three-dimensional (3D) cone-beam computed tomography angiography (CTA) of the liver for determination of subsegmental tumor-feeding vessels (FVs). Eighteen consecutive patients underwent transarterial chemoembolization (TACE) from January to October 2008 for 25 liver tumors (15 hepatocellular carcinomas [HCCs] and 10 neuroendocrine metastases). Anteroposterior projection angiogram (two-dimensional [2D]) and 3D cone-beam CTA images were acquired by injection of the common hepatic artery. Retrospectively, FVs were independently identified by three radiology technologists using a software package (S) that automatically determines FVs by analysis of 3D images. Subsequently, three interventional radiologists (IRs) independently identified FVs by reviewing the 2D images followed by examination of the 3D images. Finally, the “ground truth” for the number and location of FVs was obtained by consensus among the IRs, who were allowed to use any imaging―including 2D, 3D, and all oblique or selective angiograms―for such determination. Sensitivities, durations, and degrees of agreement for review of 2D, 3D, and S results were evaluated. Sensitivity of 3D (73%) was higher than 2D (64%) images for identification of FVs (P = 0.036). The sensitivity of S (93%) was higher than 2D (P = 0.02) and 3D (P = 0.005) imaging. The duration for review of 3D imaging was longer than that for 2D imaging (187 vs. 94 s, P = 0.0001) or for S (135 s, P = 0.0001). The degree of agreement between the IRs using 2D and 3D imaging were 54% and 62%, respectively, whereas it was 82% between the three radiology technologists using S. These preliminary data show that computed determination of FVs is both accurate and sensitive.
format Text
id pubmed-2977071
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-29770712010-12-15 Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study Deschamps, Frederic Solomon, Stephen B. Thornton, Raymond H. Rao, Pramod Hakime, Antoine Kuoch, Viseth de Baere, Thierry Cardiovasc Intervent Radiol Work In Progress The purpose of this study was to evaluate computed analysis of three-dimensional (3D) cone-beam computed tomography angiography (CTA) of the liver for determination of subsegmental tumor-feeding vessels (FVs). Eighteen consecutive patients underwent transarterial chemoembolization (TACE) from January to October 2008 for 25 liver tumors (15 hepatocellular carcinomas [HCCs] and 10 neuroendocrine metastases). Anteroposterior projection angiogram (two-dimensional [2D]) and 3D cone-beam CTA images were acquired by injection of the common hepatic artery. Retrospectively, FVs were independently identified by three radiology technologists using a software package (S) that automatically determines FVs by analysis of 3D images. Subsequently, three interventional radiologists (IRs) independently identified FVs by reviewing the 2D images followed by examination of the 3D images. Finally, the “ground truth” for the number and location of FVs was obtained by consensus among the IRs, who were allowed to use any imaging―including 2D, 3D, and all oblique or selective angiograms―for such determination. Sensitivities, durations, and degrees of agreement for review of 2D, 3D, and S results were evaluated. Sensitivity of 3D (73%) was higher than 2D (64%) images for identification of FVs (P = 0.036). The sensitivity of S (93%) was higher than 2D (P = 0.02) and 3D (P = 0.005) imaging. The duration for review of 3D imaging was longer than that for 2D imaging (187 vs. 94 s, P = 0.0001) or for S (135 s, P = 0.0001). The degree of agreement between the IRs using 2D and 3D imaging were 54% and 62%, respectively, whereas it was 82% between the three radiology technologists using S. These preliminary data show that computed determination of FVs is both accurate and sensitive. Springer-Verlag 2010-04-14 2010 /pmc/articles/PMC2977071/ /pubmed/20390271 http://dx.doi.org/10.1007/s00270-010-9846-6 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Work In Progress
Deschamps, Frederic
Solomon, Stephen B.
Thornton, Raymond H.
Rao, Pramod
Hakime, Antoine
Kuoch, Viseth
de Baere, Thierry
Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study
title Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study
title_full Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study
title_fullStr Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study
title_full_unstemmed Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study
title_short Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study
title_sort computed analysis of three-dimensional cone-beam computed tomography angiography for determination of tumor-feeding vessels during chemoembolization of liver tumor: a pilot study
topic Work In Progress
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2977071/
https://www.ncbi.nlm.nih.gov/pubmed/20390271
http://dx.doi.org/10.1007/s00270-010-9846-6
work_keys_str_mv AT deschampsfrederic computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy
AT solomonstephenb computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy
AT thorntonraymondh computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy
AT raopramod computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy
AT hakimeantoine computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy
AT kuochviseth computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy
AT debaerethierry computedanalysisofthreedimensionalconebeamcomputedtomographyangiographyfordeterminationoftumorfeedingvesselsduringchemoembolizationoflivertumorapilotstudy