Cargando…
The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day
BACKGROUND/AIMS: Technetium-99m ((99m)Tc)-pertechnetate single photon emission computed tomography (SPECT) allows non-invasive measurement of gastric accommodation (GA) and has been reported to provide the results comparable to the gold standard barostat. The reproducibility of the test when it is p...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Neurogastroenterology and Motility
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2978392/ https://www.ncbi.nlm.nih.gov/pubmed/21103421 http://dx.doi.org/10.5056/jnm.2010.16.4.401 |
_version_ | 1782191257347424256 |
---|---|
author | Vasavid, Pataramon Chaiwatanarata, Tawatchai Gonlachanvit, Sutep |
author_facet | Vasavid, Pataramon Chaiwatanarata, Tawatchai Gonlachanvit, Sutep |
author_sort | Vasavid, Pataramon |
collection | PubMed |
description | BACKGROUND/AIMS: Technetium-99m ((99m)Tc)-pertechnetate single photon emission computed tomography (SPECT) allows non-invasive measurement of gastric accommodation (GA) and has been reported to provide the results comparable to the gold standard barostat. The reproducibility of the test when it is performed at different time of the day is not known. The aim of this study was to assess the reproducibility of GA measurement by (99m)Tc-pertechnetate SPECT at the same and different time of the day. METHODS: Three GA studies were performed in each of 20 healthy volunteers (9 males, age 35 ± 9 years), 2 studies in the morning and 1 study in the afternoon. Each study was performed on separate days at least 3 days apart, in random order. The fasting gastric scintigraphy images were acquired using SPECT at 30 minutes after iv (99m)Tc-pertechnetate. Then, the scintigraphic images were acquired 50 minutes after liquid meal (250 mL, Ensure®) ingestions. Gastric volumes were calculated from transaxial gastric images using Image J software. The GA was defined as the maximum postprandial gastric volume minus fasting gastric volume. RESULTS: GA measurement by SPECT show good reproducibility at both the same and different time of the day. The intraclass correlation coefficients of GA results for the same time, the first different time and the second different time studies were 0.681, 0.630 and 0.774, respectively, and the intra-subject coefficients of variation were 13.9%, 14.1% and 8.7%, respectively. CONCLUSIONS: GA measurement by (99m)Tc-pertechnetate SPECT shows good reproducibility at both the same and different time of the day. This result suggests that the schedule time does not appear to extremely affect the gastric accommodation value. |
format | Text |
id | pubmed-2978392 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Korean Society of Neurogastroenterology and Motility |
record_format | MEDLINE/PubMed |
spelling | pubmed-29783922010-11-19 The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day Vasavid, Pataramon Chaiwatanarata, Tawatchai Gonlachanvit, Sutep J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: Technetium-99m ((99m)Tc)-pertechnetate single photon emission computed tomography (SPECT) allows non-invasive measurement of gastric accommodation (GA) and has been reported to provide the results comparable to the gold standard barostat. The reproducibility of the test when it is performed at different time of the day is not known. The aim of this study was to assess the reproducibility of GA measurement by (99m)Tc-pertechnetate SPECT at the same and different time of the day. METHODS: Three GA studies were performed in each of 20 healthy volunteers (9 males, age 35 ± 9 years), 2 studies in the morning and 1 study in the afternoon. Each study was performed on separate days at least 3 days apart, in random order. The fasting gastric scintigraphy images were acquired using SPECT at 30 minutes after iv (99m)Tc-pertechnetate. Then, the scintigraphic images were acquired 50 minutes after liquid meal (250 mL, Ensure®) ingestions. Gastric volumes were calculated from transaxial gastric images using Image J software. The GA was defined as the maximum postprandial gastric volume minus fasting gastric volume. RESULTS: GA measurement by SPECT show good reproducibility at both the same and different time of the day. The intraclass correlation coefficients of GA results for the same time, the first different time and the second different time studies were 0.681, 0.630 and 0.774, respectively, and the intra-subject coefficients of variation were 13.9%, 14.1% and 8.7%, respectively. CONCLUSIONS: GA measurement by (99m)Tc-pertechnetate SPECT shows good reproducibility at both the same and different time of the day. This result suggests that the schedule time does not appear to extremely affect the gastric accommodation value. Korean Society of Neurogastroenterology and Motility 2010-10 2010-10-30 /pmc/articles/PMC2978392/ /pubmed/21103421 http://dx.doi.org/10.5056/jnm.2010.16.4.401 Text en Copyright © 2010 Korean Society of Neurogastroenterology and Motility http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Vasavid, Pataramon Chaiwatanarata, Tawatchai Gonlachanvit, Sutep The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day |
title | The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day |
title_full | The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day |
title_fullStr | The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day |
title_full_unstemmed | The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day |
title_short | The Reproducibility of (99m)Tc-Pertechnetate Single Photon Emission Computed Tomography (SPECT) for Measurement of Gastric Accommodation in Healthy Humans: Evaluation of the Test Results Performed at the Same Time and Different Time of the Day |
title_sort | reproducibility of (99m)tc-pertechnetate single photon emission computed tomography (spect) for measurement of gastric accommodation in healthy humans: evaluation of the test results performed at the same time and different time of the day |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2978392/ https://www.ncbi.nlm.nih.gov/pubmed/21103421 http://dx.doi.org/10.5056/jnm.2010.16.4.401 |
work_keys_str_mv | AT vasavidpataramon thereproducibilityof99mtcpertechnetatesinglephotonemissioncomputedtomographyspectformeasurementofgastricaccommodationinhealthyhumansevaluationofthetestresultsperformedatthesametimeanddifferenttimeoftheday AT chaiwatanaratatawatchai thereproducibilityof99mtcpertechnetatesinglephotonemissioncomputedtomographyspectformeasurementofgastricaccommodationinhealthyhumansevaluationofthetestresultsperformedatthesametimeanddifferenttimeoftheday AT gonlachanvitsutep thereproducibilityof99mtcpertechnetatesinglephotonemissioncomputedtomographyspectformeasurementofgastricaccommodationinhealthyhumansevaluationofthetestresultsperformedatthesametimeanddifferenttimeoftheday AT vasavidpataramon reproducibilityof99mtcpertechnetatesinglephotonemissioncomputedtomographyspectformeasurementofgastricaccommodationinhealthyhumansevaluationofthetestresultsperformedatthesametimeanddifferenttimeoftheday AT chaiwatanaratatawatchai reproducibilityof99mtcpertechnetatesinglephotonemissioncomputedtomographyspectformeasurementofgastricaccommodationinhealthyhumansevaluationofthetestresultsperformedatthesametimeanddifferenttimeoftheday AT gonlachanvitsutep reproducibilityof99mtcpertechnetatesinglephotonemissioncomputedtomographyspectformeasurementofgastricaccommodationinhealthyhumansevaluationofthetestresultsperformedatthesametimeanddifferenttimeoftheday |