Cargando…

Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400

Background: Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. Purpose: To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Eun Young, Yeh, Dae Wook, Choe, Yeon Hyeon, Lee, Won Jae, Lim, Hyo Keun
Formato: Texto
Lenguaje:English
Publicado: Informa Healthcare 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2981075/
https://www.ncbi.nlm.nih.gov/pubmed/20849317
http://dx.doi.org/10.3109/02841851.2010.509740
_version_ 1782191673646776320
author Kim, Eun Young
Yeh, Dae Wook
Choe, Yeon Hyeon
Lee, Won Jae
Lim, Hyo Keun
author_facet Kim, Eun Young
Yeh, Dae Wook
Choe, Yeon Hyeon
Lee, Won Jae
Lim, Hyo Keun
author_sort Kim, Eun Young
collection PubMed
description Background: Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. Purpose: To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. Material and Methods: Patients were prospectively enrolled and were randomized into two groups (group A, 151 patients received iopromide 370, iodine flux = 1.48 g I/s; group B, 146 patients received iomeprol 400, iodine flux = 1.60 g I/s). CT attenuation was measured in the coronary arteries and great arteries and measurements were standardized based on an iodine flux of 1.5 0 g I/s. The image quality of 15 coronary artery segments was graded by two radiologists in consensus with the use of a four-point scale (1 = excellent to 4 = poor enhancement). Non-parametric statistical approaches were used to compare the two groups. Results: The median attenuation values in the coronary arteries were 454 HU and 464 HU for iopromide 370 and iomeprol 400, respectively, and they did not differ (P = 0.26). When standardizing for an iodine flux, significantly higher attenuation values were found for iopromide 370 (median = 460 HU, range = 216-791 HU) compared with iomeprol 400 (median = 435 HU, range = 195—758 HU) (P = 0.006). The median image quality score of coronary arterial segments was 1 (range 1—2) for both groups (P = 0.84). Conclusion: The attenuation values in the coronary arteries after injection of the same amount of two high iodine-concentration contrast materials at the same flow rate with different iodine fluxes are similar with no difference in image quality. With standardization for an iodine flux, the attenuation is significantly higher when using iopromide 370.
format Text
id pubmed-2981075
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-29810752010-11-16 Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400 Kim, Eun Young Yeh, Dae Wook Choe, Yeon Hyeon Lee, Won Jae Lim, Hyo Keun Acta Radiol Original Article Background: Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. Purpose: To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. Material and Methods: Patients were prospectively enrolled and were randomized into two groups (group A, 151 patients received iopromide 370, iodine flux = 1.48 g I/s; group B, 146 patients received iomeprol 400, iodine flux = 1.60 g I/s). CT attenuation was measured in the coronary arteries and great arteries and measurements were standardized based on an iodine flux of 1.5 0 g I/s. The image quality of 15 coronary artery segments was graded by two radiologists in consensus with the use of a four-point scale (1 = excellent to 4 = poor enhancement). Non-parametric statistical approaches were used to compare the two groups. Results: The median attenuation values in the coronary arteries were 454 HU and 464 HU for iopromide 370 and iomeprol 400, respectively, and they did not differ (P = 0.26). When standardizing for an iodine flux, significantly higher attenuation values were found for iopromide 370 (median = 460 HU, range = 216-791 HU) compared with iomeprol 400 (median = 435 HU, range = 195—758 HU) (P = 0.006). The median image quality score of coronary arterial segments was 1 (range 1—2) for both groups (P = 0.84). Conclusion: The attenuation values in the coronary arteries after injection of the same amount of two high iodine-concentration contrast materials at the same flow rate with different iodine fluxes are similar with no difference in image quality. With standardization for an iodine flux, the attenuation is significantly higher when using iopromide 370. Informa Healthcare 2010-11 2010-09-16 /pmc/articles/PMC2981075/ /pubmed/20849317 http://dx.doi.org/10.3109/02841851.2010.509740 Text en © 2010 Informa Healthcare http://creativecommons.org/licenses/by/2.0/ This is an open access article distributed under the Supplemental Terms and Conditions for iOpenAccess articles published in Informa Healthcare journals (http://www.informaworld.com/mpp/uploads/iopenaccess_tcs.pdf) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Eun Young
Yeh, Dae Wook
Choe, Yeon Hyeon
Lee, Won Jae
Lim, Hyo Keun
Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
title Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
title_full Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
title_fullStr Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
title_full_unstemmed Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
title_short Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400
title_sort image quality and attenuation values of multi detector ct coronary angiography using high iodine-concentration contrast material: a comparison of the use of iopromide 370 and iomeprol 400
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2981075/
https://www.ncbi.nlm.nih.gov/pubmed/20849317
http://dx.doi.org/10.3109/02841851.2010.509740
work_keys_str_mv AT kimeunyoung imagequalityandattenuationvaluesofmultidetectorctcoronaryangiographyusinghighiodineconcentrationcontrastmaterialacomparisonoftheuseofiopromide370andiomeprol400
AT yehdaewook imagequalityandattenuationvaluesofmultidetectorctcoronaryangiographyusinghighiodineconcentrationcontrastmaterialacomparisonoftheuseofiopromide370andiomeprol400
AT choeyeonhyeon imagequalityandattenuationvaluesofmultidetectorctcoronaryangiographyusinghighiodineconcentrationcontrastmaterialacomparisonoftheuseofiopromide370andiomeprol400
AT leewonjae imagequalityandattenuationvaluesofmultidetectorctcoronaryangiographyusinghighiodineconcentrationcontrastmaterialacomparisonoftheuseofiopromide370andiomeprol400
AT limhyokeun imagequalityandattenuationvaluesofmultidetectorctcoronaryangiographyusinghighiodineconcentrationcontrastmaterialacomparisonoftheuseofiopromide370andiomeprol400