Cargando…
Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
OBJECTIVE: To study the role of multidetector computed tomography (MDCT) in evaluating various complications following endovascular stenting of aortic aneurysms. MATERIALS AND METHODS: Over a period of 2 years (June 2005 to June 2007), 50 patients with aortic aneurysm on computed tomography (CT) ang...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2982200/ https://www.ncbi.nlm.nih.gov/pubmed/21187866 http://dx.doi.org/10.4103/0975-3583.70907 |
_version_ | 1782191752664317952 |
---|---|
author | Aziz, Zarina Abdul Naidu, Purushotham R. Prasad, Jagadish Kalyanpur, Arjun |
author_facet | Aziz, Zarina Abdul Naidu, Purushotham R. Prasad, Jagadish Kalyanpur, Arjun |
author_sort | Aziz, Zarina Abdul |
collection | PubMed |
description | OBJECTIVE: To study the role of multidetector computed tomography (MDCT) in evaluating various complications following endovascular stenting of aortic aneurysms. MATERIALS AND METHODS: Over a period of 2 years (June 2005 to June 2007), 50 patients with aortic aneurysm on computed tomography (CT) angiogram were prospectively studied. Images were acquired on a 64 slice multidetector row CT scanner (GE—LightSpeed VCT) after intravenous administration of nonionic iodinated contrast. Nineteen patients underwent endovascular stent-graft repair based on their medical and surgical risk factors. Stent-graft related complications were recorded by CT angiography and analyzed using descriptive statistics. RESULTS: Most common complication related to the endovascular stent-graft placement was endoleak (44.4%), followed by puncture site hematoma (27.8%), thrombotic occlusion of a limb of the bifurcated stent graft, kinking of the stent-graft, and difficult catheterization with intimal tear in the common iliac artery were 5.6% each. Poststent diameter of the aneurysm was an important predictor of endoleaks. All the patients with either increase or no change in the aneurysm size had endoleaks. CONCLUSION: MDCT angiography is an important modality in identifying, describing, and following up the various complications following endovascular repair of aortic aneurysms, endoleaks being the most common complication. Decrease in the poststent diameter of the aneurysm suggested a good outcome. |
format | Text |
id | pubmed-2982200 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-29822002010-12-23 Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm Aziz, Zarina Abdul Naidu, Purushotham R. Prasad, Jagadish Kalyanpur, Arjun J Cardiovasc Dis Res Original Paper OBJECTIVE: To study the role of multidetector computed tomography (MDCT) in evaluating various complications following endovascular stenting of aortic aneurysms. MATERIALS AND METHODS: Over a period of 2 years (June 2005 to June 2007), 50 patients with aortic aneurysm on computed tomography (CT) angiogram were prospectively studied. Images were acquired on a 64 slice multidetector row CT scanner (GE—LightSpeed VCT) after intravenous administration of nonionic iodinated contrast. Nineteen patients underwent endovascular stent-graft repair based on their medical and surgical risk factors. Stent-graft related complications were recorded by CT angiography and analyzed using descriptive statistics. RESULTS: Most common complication related to the endovascular stent-graft placement was endoleak (44.4%), followed by puncture site hematoma (27.8%), thrombotic occlusion of a limb of the bifurcated stent graft, kinking of the stent-graft, and difficult catheterization with intimal tear in the common iliac artery were 5.6% each. Poststent diameter of the aneurysm was an important predictor of endoleaks. All the patients with either increase or no change in the aneurysm size had endoleaks. CONCLUSION: MDCT angiography is an important modality in identifying, describing, and following up the various complications following endovascular repair of aortic aneurysms, endoleaks being the most common complication. Decrease in the poststent diameter of the aneurysm suggested a good outcome. Medknow Publications 2010 /pmc/articles/PMC2982200/ /pubmed/21187866 http://dx.doi.org/10.4103/0975-3583.70907 Text en © Journal of Cardiovascular Disease Research http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Aziz, Zarina Abdul Naidu, Purushotham R. Prasad, Jagadish Kalyanpur, Arjun Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
title | Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
title_full | Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
title_fullStr | Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
title_full_unstemmed | Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
title_short | Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
title_sort | role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2982200/ https://www.ncbi.nlm.nih.gov/pubmed/21187866 http://dx.doi.org/10.4103/0975-3583.70907 |
work_keys_str_mv | AT azizzarinaabdul roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm AT naidupurushothamr roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm AT prasadjagadish roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm AT kalyanpurarjun roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm |