Cargando…

Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm

OBJECTIVE: To study the role of multidetector computed tomography (MDCT) in evaluating various complications following endovascular stenting of aortic aneurysms. MATERIALS AND METHODS: Over a period of 2 years (June 2005 to June 2007), 50 patients with aortic aneurysm on computed tomography (CT) ang...

Descripción completa

Detalles Bibliográficos
Autores principales: Aziz, Zarina Abdul, Naidu, Purushotham R., Prasad, Jagadish, Kalyanpur, Arjun
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2982200/
https://www.ncbi.nlm.nih.gov/pubmed/21187866
http://dx.doi.org/10.4103/0975-3583.70907
_version_ 1782191752664317952
author Aziz, Zarina Abdul
Naidu, Purushotham R.
Prasad, Jagadish
Kalyanpur, Arjun
author_facet Aziz, Zarina Abdul
Naidu, Purushotham R.
Prasad, Jagadish
Kalyanpur, Arjun
author_sort Aziz, Zarina Abdul
collection PubMed
description OBJECTIVE: To study the role of multidetector computed tomography (MDCT) in evaluating various complications following endovascular stenting of aortic aneurysms. MATERIALS AND METHODS: Over a period of 2 years (June 2005 to June 2007), 50 patients with aortic aneurysm on computed tomography (CT) angiogram were prospectively studied. Images were acquired on a 64 slice multidetector row CT scanner (GE—LightSpeed VCT) after intravenous administration of nonionic iodinated contrast. Nineteen patients underwent endovascular stent-graft repair based on their medical and surgical risk factors. Stent-graft related complications were recorded by CT angiography and analyzed using descriptive statistics. RESULTS: Most common complication related to the endovascular stent-graft placement was endoleak (44.4%), followed by puncture site hematoma (27.8%), thrombotic occlusion of a limb of the bifurcated stent graft, kinking of the stent-graft, and difficult catheterization with intimal tear in the common iliac artery were 5.6% each. Poststent diameter of the aneurysm was an important predictor of endoleaks. All the patients with either increase or no change in the aneurysm size had endoleaks. CONCLUSION: MDCT angiography is an important modality in identifying, describing, and following up the various complications following endovascular repair of aortic aneurysms, endoleaks being the most common complication. Decrease in the poststent diameter of the aneurysm suggested a good outcome.
format Text
id pubmed-2982200
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-29822002010-12-23 Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm Aziz, Zarina Abdul Naidu, Purushotham R. Prasad, Jagadish Kalyanpur, Arjun J Cardiovasc Dis Res Original Paper OBJECTIVE: To study the role of multidetector computed tomography (MDCT) in evaluating various complications following endovascular stenting of aortic aneurysms. MATERIALS AND METHODS: Over a period of 2 years (June 2005 to June 2007), 50 patients with aortic aneurysm on computed tomography (CT) angiogram were prospectively studied. Images were acquired on a 64 slice multidetector row CT scanner (GE—LightSpeed VCT) after intravenous administration of nonionic iodinated contrast. Nineteen patients underwent endovascular stent-graft repair based on their medical and surgical risk factors. Stent-graft related complications were recorded by CT angiography and analyzed using descriptive statistics. RESULTS: Most common complication related to the endovascular stent-graft placement was endoleak (44.4%), followed by puncture site hematoma (27.8%), thrombotic occlusion of a limb of the bifurcated stent graft, kinking of the stent-graft, and difficult catheterization with intimal tear in the common iliac artery were 5.6% each. Poststent diameter of the aneurysm was an important predictor of endoleaks. All the patients with either increase or no change in the aneurysm size had endoleaks. CONCLUSION: MDCT angiography is an important modality in identifying, describing, and following up the various complications following endovascular repair of aortic aneurysms, endoleaks being the most common complication. Decrease in the poststent diameter of the aneurysm suggested a good outcome. Medknow Publications 2010 /pmc/articles/PMC2982200/ /pubmed/21187866 http://dx.doi.org/10.4103/0975-3583.70907 Text en © Journal of Cardiovascular Disease Research http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Aziz, Zarina Abdul
Naidu, Purushotham R.
Prasad, Jagadish
Kalyanpur, Arjun
Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
title Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
title_full Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
title_fullStr Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
title_full_unstemmed Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
title_short Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
title_sort role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2982200/
https://www.ncbi.nlm.nih.gov/pubmed/21187866
http://dx.doi.org/10.4103/0975-3583.70907
work_keys_str_mv AT azizzarinaabdul roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm
AT naidupurushothamr roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm
AT prasadjagadish roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm
AT kalyanpurarjun roleofmultidetectorcomputedtomographyinevaluatingcomplicationsfollowingendovascularrepairofaorticaneurysm