Electron beam characteristics at extended source-to-surface distances for irregular cut-outs

Electron beam therapy is widely used in the management of cancers. The rapid dose fall-off and the short range of an electron beam enable the treatment of lesions close to the surface, while sparing the underlying tissues. In an extended source-to-surface (SSD) treatment with irregular field sizes d...

Descripción completa

Detalles Bibliográficos
Autores principales: Arunkumar, T., Supe, Sanjay S., Ravikumar, M., Sathiyan, S., Ganesh, M.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2990115/
https://www.ncbi.nlm.nih.gov/pubmed/21170185
http://dx.doi.org/10.4103/0971-6203.71763
_version_ 1782192440213504000
author Arunkumar, T.
Supe, Sanjay S.
Ravikumar, M.
Sathiyan, S.
Ganesh, M.
author_facet Arunkumar, T.
Supe, Sanjay S.
Ravikumar, M.
Sathiyan, S.
Ganesh, M.
author_sort Arunkumar, T.
collection PubMed
description Electron beam therapy is widely used in the management of cancers. The rapid dose fall-off and the short range of an electron beam enable the treatment of lesions close to the surface, while sparing the underlying tissues. In an extended source-to-surface (SSD) treatment with irregular field sizes defined by cerrobend cutouts, underdosage of the lateral tissue may occur due to reduced beam flatness and uniformity. To study the changes in the beam characteristics, the depth dose, beam profile, and isodose distributions were measured at different SSDs for regular 10 × 10 cm(2) and 15 × 15 cm(2) cone, and for irregular cutouts of field size 6.5 × 9 cm(2) and 11.5 × 15 cm(2) for beam energies ranging from 6 to 20 MeV. The PDD, beam flatness, symmetry and uniformity index were compared. For lower energy (6 MeV), there was no change in the depth of maximum dose (R100) as SSD increased, but for higher energy (20 MeV), the R(100) depth increased from 2 cm to 3 cm as SSD increased. This shows that as SSD increases there is an increase in the depth of the maximum dose for higher energy beams. There is a +7 mm shift in the R(100) depth when compared with regular and irregular field sizes. The symmetry was found to be within limits for all the field sizes as the treatment distance extended as per International Electro technical Commision (IEC) protocol. There was a loss of beam flatness for irregular fields and it was more pronounced for lower energies as compared with higher energies, so that the clinically useful isodose level (80% and 90%) width decreases with increase in SSD. This suggests that target coverage at extended SSD with irregular cut-outs may be inadequate unless relatively large fields are used.
format Text
id pubmed-2990115
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-29901152010-12-17 Electron beam characteristics at extended source-to-surface distances for irregular cut-outs Arunkumar, T. Supe, Sanjay S. Ravikumar, M. Sathiyan, S. Ganesh, M. J Med Phys Original Article Electron beam therapy is widely used in the management of cancers. The rapid dose fall-off and the short range of an electron beam enable the treatment of lesions close to the surface, while sparing the underlying tissues. In an extended source-to-surface (SSD) treatment with irregular field sizes defined by cerrobend cutouts, underdosage of the lateral tissue may occur due to reduced beam flatness and uniformity. To study the changes in the beam characteristics, the depth dose, beam profile, and isodose distributions were measured at different SSDs for regular 10 × 10 cm(2) and 15 × 15 cm(2) cone, and for irregular cutouts of field size 6.5 × 9 cm(2) and 11.5 × 15 cm(2) for beam energies ranging from 6 to 20 MeV. The PDD, beam flatness, symmetry and uniformity index were compared. For lower energy (6 MeV), there was no change in the depth of maximum dose (R100) as SSD increased, but for higher energy (20 MeV), the R(100) depth increased from 2 cm to 3 cm as SSD increased. This shows that as SSD increases there is an increase in the depth of the maximum dose for higher energy beams. There is a +7 mm shift in the R(100) depth when compared with regular and irregular field sizes. The symmetry was found to be within limits for all the field sizes as the treatment distance extended as per International Electro technical Commision (IEC) protocol. There was a loss of beam flatness for irregular fields and it was more pronounced for lower energies as compared with higher energies, so that the clinically useful isodose level (80% and 90%) width decreases with increase in SSD. This suggests that target coverage at extended SSD with irregular cut-outs may be inadequate unless relatively large fields are used. Medknow Publications 2010 /pmc/articles/PMC2990115/ /pubmed/21170185 http://dx.doi.org/10.4103/0971-6203.71763 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Arunkumar, T.
Supe, Sanjay S.
Ravikumar, M.
Sathiyan, S.
Ganesh, M.
Electron beam characteristics at extended source-to-surface distances for irregular cut-outs
title Electron beam characteristics at extended source-to-surface distances for irregular cut-outs
title_full Electron beam characteristics at extended source-to-surface distances for irregular cut-outs
title_fullStr Electron beam characteristics at extended source-to-surface distances for irregular cut-outs
title_full_unstemmed Electron beam characteristics at extended source-to-surface distances for irregular cut-outs
title_short Electron beam characteristics at extended source-to-surface distances for irregular cut-outs
title_sort electron beam characteristics at extended source-to-surface distances for irregular cut-outs
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2990115/
https://www.ncbi.nlm.nih.gov/pubmed/21170185
http://dx.doi.org/10.4103/0971-6203.71763
work_keys_str_mv AT arunkumart electronbeamcharacteristicsatextendedsourcetosurfacedistancesforirregularcutouts
AT supesanjays electronbeamcharacteristicsatextendedsourcetosurfacedistancesforirregularcutouts
AT ravikumarm electronbeamcharacteristicsatextendedsourcetosurfacedistancesforirregularcutouts
AT sathiyans electronbeamcharacteristicsatextendedsourcetosurfacedistancesforirregularcutouts
AT ganeshm electronbeamcharacteristicsatextendedsourcetosurfacedistancesforirregularcutouts