Cargando…

Open interlocked nailing without a targeting device or X-ray guidance for non-union of the femur: a case series

From October 2005 to August 2007, we operated on six patients who had femoral non-unions and performed interlocked intramedullary nailing without X-ray guidance or a targeting device. There were three fractures of the distal femur, two fractures of the mid-shaft and one of the proximal femur. Fatigu...

Descripción completa

Detalles Bibliográficos
Autores principales: Ogbemudia, Alfred O., Bafor, Anire, Igbinovia, Efosa, Ogbemudia, Peter E.
Formato: Texto
Lenguaje:English
Publicado: Springer Milan 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2994629/
https://www.ncbi.nlm.nih.gov/pubmed/21286356
http://dx.doi.org/10.1007/s11751-010-0095-7
Descripción
Sumario:From October 2005 to August 2007, we operated on six patients who had femoral non-unions and performed interlocked intramedullary nailing without X-ray guidance or a targeting device. There were three fractures of the distal femur, two fractures of the mid-shaft and one of the proximal femur. Fatigue failure of a non-interlocked Kuntscher nail and one nail migration were the presenting features in two patients. The presence of sclerosis of the bone ends in four cases and a need for cancellous bone grafts at the site of non-union in all patients made wide dissection and open reduction unavoidable. There was a limb length discrepancy in all patients before surgical intervention. Partial weight bearing was commenced at 6 weeks post-operation. There was no case of wound infection. There was no misplaced screw. Minimum range of knee flexion was 105° at 2 months post-operation. These early results call for a closer look at this cheap, safe and effective means of handling femoral non-union in third world societies where there is paucity of instrumentation and implants for interlocked nailing.