Cargando…

Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis

BACKGROUND: Several studies have been published in the literature on the diagnostic accuracy of NT-pro-BNP for pleural effusions from heart failure in the last decade. The purpose of our study was to perform a systematic review and meta-analysis on the diagnostic accuracy of pleural fluid NT-pro-BNP...

Descripción completa

Detalles Bibliográficos
Autores principales: Janda, Surinder, Swiston, John
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2994800/
https://www.ncbi.nlm.nih.gov/pubmed/21092122
http://dx.doi.org/10.1186/1471-2466-10-58
_version_ 1782193001012920320
author Janda, Surinder
Swiston, John
author_facet Janda, Surinder
Swiston, John
author_sort Janda, Surinder
collection PubMed
description BACKGROUND: Several studies have been published in the literature on the diagnostic accuracy of NT-pro-BNP for pleural effusions from heart failure in the last decade. The purpose of our study was to perform a systematic review and meta-analysis on the diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin. METHODS: MEDLINE, EMBASE, PapersFirst, and the Cochrane collaboration and the Cochrane Register of controlled trials were searched. All searches were inclusive as of March 2010. Studies were only included if the absolute number of true-positive, false-negative, true-negative, and false-positive observations were available, and the "reference standards" were described clearly. Two investigators independently reviewed articles and extracted data. Quality was assessed with the Quality Assessment for Diagnostic Accuracy Studies (QUADAS). The bivariate model for diagnostic meta-analysis was used to obtain a pooled sensitivity and a pooled specificity. RESULTS: Ten studies (total number of patients 1120) were included in the meta-analysis. The average pleural fluid NT-pro-BNP level in effusions of cardiac origin was 6140 pg/mL. The pooled sensitivity and specificity of all studies combined was 94% (95% CI: 90-97) and 94% (95% CI: 89-97) respectively. The pooled positive likelihood ratio was 15.2 (95% CI: 8.1-28.7) and the pooled negative likelihood ratio was 0.06 (95% CI: 0.03-0.11). The area under the ROC curve was 0.98 (95% CI: 0.96-0.99) and the diagnostic odds ratio was 246 (95% CI: 81-745). CONCLUSIONS: Pleural fluid NT-pro-BNP is a very useful biomarker with high diagnostic accuracy for distinguishing pleural effusions of cardiac origin.
format Text
id pubmed-2994800
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-29948002010-12-01 Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis Janda, Surinder Swiston, John BMC Pulm Med Research Article BACKGROUND: Several studies have been published in the literature on the diagnostic accuracy of NT-pro-BNP for pleural effusions from heart failure in the last decade. The purpose of our study was to perform a systematic review and meta-analysis on the diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin. METHODS: MEDLINE, EMBASE, PapersFirst, and the Cochrane collaboration and the Cochrane Register of controlled trials were searched. All searches were inclusive as of March 2010. Studies were only included if the absolute number of true-positive, false-negative, true-negative, and false-positive observations were available, and the "reference standards" were described clearly. Two investigators independently reviewed articles and extracted data. Quality was assessed with the Quality Assessment for Diagnostic Accuracy Studies (QUADAS). The bivariate model for diagnostic meta-analysis was used to obtain a pooled sensitivity and a pooled specificity. RESULTS: Ten studies (total number of patients 1120) were included in the meta-analysis. The average pleural fluid NT-pro-BNP level in effusions of cardiac origin was 6140 pg/mL. The pooled sensitivity and specificity of all studies combined was 94% (95% CI: 90-97) and 94% (95% CI: 89-97) respectively. The pooled positive likelihood ratio was 15.2 (95% CI: 8.1-28.7) and the pooled negative likelihood ratio was 0.06 (95% CI: 0.03-0.11). The area under the ROC curve was 0.98 (95% CI: 0.96-0.99) and the diagnostic odds ratio was 246 (95% CI: 81-745). CONCLUSIONS: Pleural fluid NT-pro-BNP is a very useful biomarker with high diagnostic accuracy for distinguishing pleural effusions of cardiac origin. BioMed Central 2010-11-20 /pmc/articles/PMC2994800/ /pubmed/21092122 http://dx.doi.org/10.1186/1471-2466-10-58 Text en Copyright ©2010 Janda and Swiston; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Janda, Surinder
Swiston, John
Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis
title Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis
title_full Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis
title_fullStr Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis
title_full_unstemmed Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis
title_short Diagnostic accuracy of pleural fluid NT-pro-BNP for pleural effusions of cardiac origin: a systematic review and meta-analysis
title_sort diagnostic accuracy of pleural fluid nt-pro-bnp for pleural effusions of cardiac origin: a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2994800/
https://www.ncbi.nlm.nih.gov/pubmed/21092122
http://dx.doi.org/10.1186/1471-2466-10-58
work_keys_str_mv AT jandasurinder diagnosticaccuracyofpleuralfluidntprobnpforpleuraleffusionsofcardiacoriginasystematicreviewandmetaanalysis
AT swistonjohn diagnosticaccuracyofpleuralfluidntprobnpforpleuraleffusionsofcardiacoriginasystematicreviewandmetaanalysis