Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction
PURPOSE: The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS: Patients who were implanted with permanent pacemak...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2995980/ https://www.ncbi.nlm.nih.gov/pubmed/20879047 http://dx.doi.org/10.3349/ymj.2010.51.6.832 |
_version_ | 1782193140496596992 |
---|---|
author | Kim, Won Ho Joung, Boyoung Shim, Jaemin Park, Jong Sung Hwang, Eui-Seock Pak, Hui-Nam Kim, Sungsoon Lee, Moonhyoung |
author_facet | Kim, Won Ho Joung, Boyoung Shim, Jaemin Park, Jong Sung Hwang, Eui-Seock Pak, Hui-Nam Kim, Sungsoon Lee, Moonhyoung |
author_sort | Kim, Won Ho |
collection | PubMed |
description | PURPOSE: The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS: Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. RESULTS: The baseline characteristics were comparable between the two groups, with a mean follow-up duration of 69 months. The incidence of death did not show statistical difference. However, the incidence of hospitalization for congestive heart failure (CHF) was significantly lower in the AAI(R) group (0%) than the DDD(R) group (8.8%, p = 0.03). Also, atrial fibrillation (AF) was found in 2.8% in the AAI(R) group, which was statistically different from 15.2% of patients in the DDD(R) group (p = 0.01). Four patients (5.5%) with AAI(R) developed AV block, and subsequently switched to DDD(R) pacing. The risk of AF was lower in the patients implanted with AAI(R) than those with DDD(R) [hazard ratio (HR), 0.84; 95% confidence interval, 0.72 to 0.97, p = 0.02]. CONCLUSION: In patients with SND and intact AV conduction, AAI(R) pacing can achieve a better clinical outcome in terms of occurrence of CHF and AF than DDD(R) pacing. These findings support AAI(R) pacing as the preferred pacing mode in patients with SND and intact AV conduction. |
format | Text |
id | pubmed-2995980 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-29959802010-12-07 Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction Kim, Won Ho Joung, Boyoung Shim, Jaemin Park, Jong Sung Hwang, Eui-Seock Pak, Hui-Nam Kim, Sungsoon Lee, Moonhyoung Yonsei Med J Original Article PURPOSE: The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS: Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. RESULTS: The baseline characteristics were comparable between the two groups, with a mean follow-up duration of 69 months. The incidence of death did not show statistical difference. However, the incidence of hospitalization for congestive heart failure (CHF) was significantly lower in the AAI(R) group (0%) than the DDD(R) group (8.8%, p = 0.03). Also, atrial fibrillation (AF) was found in 2.8% in the AAI(R) group, which was statistically different from 15.2% of patients in the DDD(R) group (p = 0.01). Four patients (5.5%) with AAI(R) developed AV block, and subsequently switched to DDD(R) pacing. The risk of AF was lower in the patients implanted with AAI(R) than those with DDD(R) [hazard ratio (HR), 0.84; 95% confidence interval, 0.72 to 0.97, p = 0.02]. CONCLUSION: In patients with SND and intact AV conduction, AAI(R) pacing can achieve a better clinical outcome in terms of occurrence of CHF and AF than DDD(R) pacing. These findings support AAI(R) pacing as the preferred pacing mode in patients with SND and intact AV conduction. Yonsei University College of Medicine 2010-11-01 2010-09-30 /pmc/articles/PMC2995980/ /pubmed/20879047 http://dx.doi.org/10.3349/ymj.2010.51.6.832 Text en © Copyright: Yonsei University College of Medicine 2010 http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Won Ho Joung, Boyoung Shim, Jaemin Park, Jong Sung Hwang, Eui-Seock Pak, Hui-Nam Kim, Sungsoon Lee, Moonhyoung Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction |
title | Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction |
title_full | Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction |
title_fullStr | Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction |
title_full_unstemmed | Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction |
title_short | Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction |
title_sort | long-term outcome of single-chamber atrial pacing compared with dual-chamber pacing in patients with sinus-node dysfunction and intact atrioventricular node conduction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2995980/ https://www.ncbi.nlm.nih.gov/pubmed/20879047 http://dx.doi.org/10.3349/ymj.2010.51.6.832 |
work_keys_str_mv | AT kimwonho longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT joungboyoung longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT shimjaemin longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT parkjongsung longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT hwangeuiseock longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT pakhuinam longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT kimsungsoon longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction AT leemoonhyoung longtermoutcomeofsinglechamberatrialpacingcomparedwithdualchamberpacinginpatientswithsinusnodedysfunctionandintactatrioventricularnodeconduction |