Cargando…
Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis
BACKGROUND/AIMS: The aim of this study was to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at the peri-stent reference segments after bare-metal stent implantation. METHODS: We retrospectively investigated serial intravascular ultrasound...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Association of Internal Medicine
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2997963/ https://www.ncbi.nlm.nih.gov/pubmed/21179272 http://dx.doi.org/10.3904/kjim.2010.25.4.356 |
_version_ | 1782193331878494208 |
---|---|
author | Hong, Young Joon Jeong, Myung Ho Choi, Yun Ha Ma, Eun Hye Ko, Jum Suk Lee, Min Goo Park, Keun Ho Sim, Doo Sun Yoon, Nam Sik Youn, Hyun Ju Kim, Kye Hun Park, Hyung Wook Kim, Ju Han Ahn, Youngkeun Cho, Jeong Gwan Park, Jong Chun Kang, Jung Chaee |
author_facet | Hong, Young Joon Jeong, Myung Ho Choi, Yun Ha Ma, Eun Hye Ko, Jum Suk Lee, Min Goo Park, Keun Ho Sim, Doo Sun Yoon, Nam Sik Youn, Hyun Ju Kim, Kye Hun Park, Hyung Wook Kim, Ju Han Ahn, Youngkeun Cho, Jeong Gwan Park, Jong Chun Kang, Jung Chaee |
author_sort | Hong, Young Joon |
collection | PubMed |
description | BACKGROUND/AIMS: The aim of this study was to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at the peri-stent reference segments after bare-metal stent implantation. METHODS: We retrospectively investigated serial intravascular ultrasound (IVUS) findings in 380 peri-stent reference segments (184 proximal and 196 distal to the stent) in 196 patients (simvastatin group, n = 132 vs. non-statin group, n = 64). Quantitative volumetric IVUS analysis was performed in 5-mm vessel segments proximal and distal to the stent. RESULTS: IVUS follow-up was performed at a mean of 9.4 months after stenting (range, 5 to 19 months). No significant differences were observed in the changes in mean plaque plus media (P&M) area, mean lumen area, and mean external elastic membrane (EEM) area from post-stenting to follow-up at both proximal and distal edges between the simvastatin and non-statin group. Although lumen loss within the first 3 mm from each stent edge was primarily due to an increase in P&M area rather than a change in EEM area, and lumen loss beyond 3 mm from each stent edge was due to a combination of increased P&M area and decreased EEM area, no significant differences in changes were observed in P&M, EEM, and lumen area at every 1-mm subsegment between the simvastatin and non-statin group. CONCLUSIONS: A usual dose of simvastatin does not inhibit plaque progression and lumen loss and does not affect vascular remodeling in peri-stent reference segments in patients undergoing bare-metal stent implantation. |
format | Text |
id | pubmed-2997963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | The Korean Association of Internal Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-29979632010-12-22 Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis Hong, Young Joon Jeong, Myung Ho Choi, Yun Ha Ma, Eun Hye Ko, Jum Suk Lee, Min Goo Park, Keun Ho Sim, Doo Sun Yoon, Nam Sik Youn, Hyun Ju Kim, Kye Hun Park, Hyung Wook Kim, Ju Han Ahn, Youngkeun Cho, Jeong Gwan Park, Jong Chun Kang, Jung Chaee Korean J Intern Med Original Article BACKGROUND/AIMS: The aim of this study was to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at the peri-stent reference segments after bare-metal stent implantation. METHODS: We retrospectively investigated serial intravascular ultrasound (IVUS) findings in 380 peri-stent reference segments (184 proximal and 196 distal to the stent) in 196 patients (simvastatin group, n = 132 vs. non-statin group, n = 64). Quantitative volumetric IVUS analysis was performed in 5-mm vessel segments proximal and distal to the stent. RESULTS: IVUS follow-up was performed at a mean of 9.4 months after stenting (range, 5 to 19 months). No significant differences were observed in the changes in mean plaque plus media (P&M) area, mean lumen area, and mean external elastic membrane (EEM) area from post-stenting to follow-up at both proximal and distal edges between the simvastatin and non-statin group. Although lumen loss within the first 3 mm from each stent edge was primarily due to an increase in P&M area rather than a change in EEM area, and lumen loss beyond 3 mm from each stent edge was due to a combination of increased P&M area and decreased EEM area, no significant differences in changes were observed in P&M, EEM, and lumen area at every 1-mm subsegment between the simvastatin and non-statin group. CONCLUSIONS: A usual dose of simvastatin does not inhibit plaque progression and lumen loss and does not affect vascular remodeling in peri-stent reference segments in patients undergoing bare-metal stent implantation. The Korean Association of Internal Medicine 2010-12 2010-11-27 /pmc/articles/PMC2997963/ /pubmed/21179272 http://dx.doi.org/10.3904/kjim.2010.25.4.356 Text en Copyright © 2010 The Korean Association of Internal Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Hong, Young Joon Jeong, Myung Ho Choi, Yun Ha Ma, Eun Hye Ko, Jum Suk Lee, Min Goo Park, Keun Ho Sim, Doo Sun Yoon, Nam Sik Youn, Hyun Ju Kim, Kye Hun Park, Hyung Wook Kim, Ju Han Ahn, Youngkeun Cho, Jeong Gwan Park, Jong Chun Kang, Jung Chaee Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis |
title | Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis |
title_full | Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis |
title_fullStr | Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis |
title_full_unstemmed | Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis |
title_short | Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis |
title_sort | usual dose of simvastatin does not inhibit plaque progression and lumen loss at the peri-stent reference segments after bare-metal stent implantation: a serial intravascular ultrasound analysis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2997963/ https://www.ncbi.nlm.nih.gov/pubmed/21179272 http://dx.doi.org/10.3904/kjim.2010.25.4.356 |
work_keys_str_mv | AT hongyoungjoon usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT jeongmyungho usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT choiyunha usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT maeunhye usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT kojumsuk usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT leemingoo usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT parkkeunho usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT simdoosun usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT yoonnamsik usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT younhyunju usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT kimkyehun usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT parkhyungwook usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT kimjuhan usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT ahnyoungkeun usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT chojeonggwan usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT parkjongchun usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis AT kangjungchaee usualdoseofsimvastatindoesnotinhibitplaqueprogressionandlumenlossattheperistentreferencesegmentsafterbaremetalstentimplantationaserialintravascularultrasoundanalysis |