Cargando…

Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion

BACKGROUND: Unlike the commonly used method of blue-white screening for gene insertion, a fluorescent protein-based screening method offers a gain-of-function screening process without using any co-factors and a gene fusion product with a fluorescent protein reporter that is further useful in cell i...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Stanley S. C., Truong, Kevin
Formato: Texto
Lenguaje:English
Publicado: Public Library of Science 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3000809/
https://www.ncbi.nlm.nih.gov/pubmed/21170317
http://dx.doi.org/10.1371/journal.pone.0014274
_version_ 1782193566174412800
author Wong, Stanley S. C.
Truong, Kevin
author_facet Wong, Stanley S. C.
Truong, Kevin
author_sort Wong, Stanley S. C.
collection PubMed
description BACKGROUND: Unlike the commonly used method of blue-white screening for gene insertion, a fluorescent protein-based screening method offers a gain-of-function screening process without using any co-factors and a gene fusion product with a fluorescent protein reporter that is further useful in cell imaging studies. However, complications related to protein-folding efficiencies of the gene insert in fusion with fluorescent protein reporters prevent effective on-plate bacterial colony selection leading to its limited use. METHODOLOGY/PRINCIPAL FINDINGS: Here, we present three methods to tackle this problem. Our first method promotes the folding of the gene insert by using an N-terminal protein such as calmodulin that is well folded and expressed. Under this method, fluorescence was increased more than 30x over control allowing for enhanced screening. Our second method creates a fluorescent protein that is N-terminal to the gene upon insertion, thereby reducing the dependency of the fluorescent protein reporter on the folding of the gene insert. Our third method eliminates any dependence of the fluorescent protein reporter on the folding of the gene insert by using a stop and start sequence for protein translation. CONCLUSIONS/SIGNIFICANCE: The three methods together will expand the usefulness of fluorescence on-plate screening and offer a powerful alternative to blue-white screening.
format Text
id pubmed-3000809
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-30008092010-12-17 Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion Wong, Stanley S. C. Truong, Kevin PLoS One Research Article BACKGROUND: Unlike the commonly used method of blue-white screening for gene insertion, a fluorescent protein-based screening method offers a gain-of-function screening process without using any co-factors and a gene fusion product with a fluorescent protein reporter that is further useful in cell imaging studies. However, complications related to protein-folding efficiencies of the gene insert in fusion with fluorescent protein reporters prevent effective on-plate bacterial colony selection leading to its limited use. METHODOLOGY/PRINCIPAL FINDINGS: Here, we present three methods to tackle this problem. Our first method promotes the folding of the gene insert by using an N-terminal protein such as calmodulin that is well folded and expressed. Under this method, fluorescence was increased more than 30x over control allowing for enhanced screening. Our second method creates a fluorescent protein that is N-terminal to the gene upon insertion, thereby reducing the dependency of the fluorescent protein reporter on the folding of the gene insert. Our third method eliminates any dependence of the fluorescent protein reporter on the folding of the gene insert by using a stop and start sequence for protein translation. CONCLUSIONS/SIGNIFICANCE: The three methods together will expand the usefulness of fluorescence on-plate screening and offer a powerful alternative to blue-white screening. Public Library of Science 2010-12-10 /pmc/articles/PMC3000809/ /pubmed/21170317 http://dx.doi.org/10.1371/journal.pone.0014274 Text en Wong, Truong. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wong, Stanley S. C.
Truong, Kevin
Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion
title Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion
title_full Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion
title_fullStr Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion
title_full_unstemmed Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion
title_short Fluorescent Protein-Based Methods for On-Plate Screening of Gene Insertion
title_sort fluorescent protein-based methods for on-plate screening of gene insertion
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3000809/
https://www.ncbi.nlm.nih.gov/pubmed/21170317
http://dx.doi.org/10.1371/journal.pone.0014274
work_keys_str_mv AT wongstanleysc fluorescentproteinbasedmethodsforonplatescreeningofgeneinsertion
AT truongkevin fluorescentproteinbasedmethodsforonplatescreeningofgeneinsertion