Cargando…

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold

BACKGROUND: T1 mapping allows direct in-vivo quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinicall...

Descripción completa

Detalles Bibliográficos
Autores principales: Piechnik, Stefan K, Ferreira, Vanessa M, Dall'Armellina, Erica, Cochlin, Lowri E, Greiser, Andreas, Neubauer, Stefan, Robson, Matthew D
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3001433/
https://www.ncbi.nlm.nih.gov/pubmed/21092095
http://dx.doi.org/10.1186/1532-429X-12-69
_version_ 1782193625842581504
author Piechnik, Stefan K
Ferreira, Vanessa M
Dall'Armellina, Erica
Cochlin, Lowri E
Greiser, Andreas
Neubauer, Stefan
Robson, Matthew D
author_facet Piechnik, Stefan K
Ferreira, Vanessa M
Dall'Armellina, Erica
Cochlin, Lowri E
Greiser, Andreas
Neubauer, Stefan
Robson, Matthew D
author_sort Piechnik, Stefan K
collection PubMed
description BACKGROUND: T1 mapping allows direct in-vivo quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinically applicable, pulse sequence for myocardial T1-mapping that is compatible with typical limits for end-expiration breath-holding in patients. MATERIALS AND METHODS: The Shortened MOdified Look-Locker Inversion recovery (ShMOLLI) method uses sequential inversion recovery measurements within a single short breath-hold. Full recovery of the longitudinal magnetisation between sequential inversion pulses is not achieved, but conditional interpretation of samples for reconstruction of T1-maps is used to yield accurate measurements, and this algorithm is implemented directly on the scanner. We performed computer simulations for 100 ms<T1 < 2.7 s and heart rates 40-100 bpm followed by phantom validation at 1.5T and 3T. In-vivo myocardial T1-mapping using this method and the previous gold-standard (MOLLI) was performed in 10 healthy volunteers at 1.5T and 3T, 4 volunteers with contrast injection at 1.5T, and 4 patients with recent myocardial infarction (MI) at 3T. RESULTS: We found good agreement between the average ShMOLLI and MOLLI estimates for T1 < 1200 ms. In contrast to the original method, ShMOLLI showed no dependence on heart rates for long T1 values, with estimates characterized by a constant 4% underestimation for T1 = 800-2700 ms. In-vivo, ShMOLLI measurements required 9.0 ± 1.1 s (MOLLI = 17.6 ± 2.9 s). Average healthy myocardial T1 s by ShMOLLI at 1.5T were 966 ± 48 ms (mean ± SD) and 1166 ± 60 ms at 3T. In MI patients, the T1 in unaffected myocardium (1216 ± 42 ms) was similar to controls at 3T. Ischemically injured myocardium showed increased T1 = 1432 ± 33 ms (p < 0.001). The difference between MI and remote myocardium was estimated 15% larger by ShMOLLI than MOLLI (p < 0.04) which suffers from heart rate dependencies for long T1. The in-vivo variability within ShMOLLI T1-maps was only 14% (1.5T) or 18% (3T) higher than the MOLLI maps, but the MOLLI acquisitions were twice longer than ShMOLLI acquisitions. CONCLUSION: ShMOLLI is an efficient method that generates immediate, high-resolution myocardial T1-maps in a short breath-hold with high precision. This technique provides a valuable clinically applicable tool for myocardial tissue characterisation.
format Text
id pubmed-3001433
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-30014332010-12-15 Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold Piechnik, Stefan K Ferreira, Vanessa M Dall'Armellina, Erica Cochlin, Lowri E Greiser, Andreas Neubauer, Stefan Robson, Matthew D J Cardiovasc Magn Reson Research BACKGROUND: T1 mapping allows direct in-vivo quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinically applicable, pulse sequence for myocardial T1-mapping that is compatible with typical limits for end-expiration breath-holding in patients. MATERIALS AND METHODS: The Shortened MOdified Look-Locker Inversion recovery (ShMOLLI) method uses sequential inversion recovery measurements within a single short breath-hold. Full recovery of the longitudinal magnetisation between sequential inversion pulses is not achieved, but conditional interpretation of samples for reconstruction of T1-maps is used to yield accurate measurements, and this algorithm is implemented directly on the scanner. We performed computer simulations for 100 ms<T1 < 2.7 s and heart rates 40-100 bpm followed by phantom validation at 1.5T and 3T. In-vivo myocardial T1-mapping using this method and the previous gold-standard (MOLLI) was performed in 10 healthy volunteers at 1.5T and 3T, 4 volunteers with contrast injection at 1.5T, and 4 patients with recent myocardial infarction (MI) at 3T. RESULTS: We found good agreement between the average ShMOLLI and MOLLI estimates for T1 < 1200 ms. In contrast to the original method, ShMOLLI showed no dependence on heart rates for long T1 values, with estimates characterized by a constant 4% underestimation for T1 = 800-2700 ms. In-vivo, ShMOLLI measurements required 9.0 ± 1.1 s (MOLLI = 17.6 ± 2.9 s). Average healthy myocardial T1 s by ShMOLLI at 1.5T were 966 ± 48 ms (mean ± SD) and 1166 ± 60 ms at 3T. In MI patients, the T1 in unaffected myocardium (1216 ± 42 ms) was similar to controls at 3T. Ischemically injured myocardium showed increased T1 = 1432 ± 33 ms (p < 0.001). The difference between MI and remote myocardium was estimated 15% larger by ShMOLLI than MOLLI (p < 0.04) which suffers from heart rate dependencies for long T1. The in-vivo variability within ShMOLLI T1-maps was only 14% (1.5T) or 18% (3T) higher than the MOLLI maps, but the MOLLI acquisitions were twice longer than ShMOLLI acquisitions. CONCLUSION: ShMOLLI is an efficient method that generates immediate, high-resolution myocardial T1-maps in a short breath-hold with high precision. This technique provides a valuable clinically applicable tool for myocardial tissue characterisation. BioMed Central 2010-11-19 /pmc/articles/PMC3001433/ /pubmed/21092095 http://dx.doi.org/10.1186/1532-429X-12-69 Text en Copyright ©2010 Piechnik et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Piechnik, Stefan K
Ferreira, Vanessa M
Dall'Armellina, Erica
Cochlin, Lowri E
Greiser, Andreas
Neubauer, Stefan
Robson, Matthew D
Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
title Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
title_full Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
title_fullStr Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
title_full_unstemmed Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
title_short Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
title_sort shortened modified look-locker inversion recovery (shmolli) for clinical myocardial t1-mapping at 1.5 and 3 t within a 9 heartbeat breathhold
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3001433/
https://www.ncbi.nlm.nih.gov/pubmed/21092095
http://dx.doi.org/10.1186/1532-429X-12-69
work_keys_str_mv AT piechnikstefank shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold
AT ferreiravanessam shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold
AT dallarmellinaerica shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold
AT cochlinlowrie shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold
AT greiserandreas shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold
AT neubauerstefan shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold
AT robsonmatthewd shortenedmodifiedlooklockerinversionrecoveryshmolliforclinicalmyocardialt1mappingat15and3twithina9heartbeatbreathhold